Eugeniuš Stupak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eugeniuš Stupak has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Arnas Kačeniauskas
Laboratory of Parallel Computing, Faculty of Fundamental Sciences, Vilnius Gediminas Technical University, LT-10223 Vilnius, Lithuania
2 shared publications - Ruslan Pacevič
Department of Graphical Systems, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania
2 shared publications - Agnieszka Grabias
Łukasiewicz Research Network—Institute of Microelectronics and Photonics Warsaw Poland
1 shared publication - Algirdas Maknickas
Department Biomechanical Engineering, Vilnius Gediminas Technical University, Plytines Str. 25, LT-10105 Vilnius, Lithuania
1 shared publication - Alicia Menéndez Hurtado
Department of Applied Mechanics, Vilnius Gediminas Technical University, Saulėtekio al. 11, 10224 Vilnius, Lithuania
1 shared publication - Giedrius Davidavicius
Clinic of Cardiac and Vascular Diseases, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
1 shared publication
Latest Publications
- Open Access
- 19 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3331
New Multiscale Approach of Complex Modelling Chordae Tendineae Considering Strain-Dependent Modulus of Elasticity
Understanding the nonlinear mechanical behaviour of mitral valve chordae tendineae is critical for accurate biomechanical modelling in cardiac simulations. This study integrates high-resolution 3D finite element analysis with experimentally derived Cauchy stress–Green–Lagrange strain data to capture both material and geometric nonlinearities. A one-dimensional formulation incorporating strain-dependent elasticity and large deformation kinematics was developed and validated against 3D simulations in COMSOL Multiphysics. Calibrated using experimental stress–strain data and validated against high-fidelity 3D finite element simulations in COMSOL, it reveals that neglecting transverse deformation overestimates axial force by 7%. Cross-sectional area reduction during stretch remained consistently around 12%, underscoring the importance of Poisson effects. A polynomial fit to the strain-dependent modulus of elasticity enables efficient force prediction with excellent agreement to experimental data. These results advance the mathematical modelling of biological tissues with nonlinear hyperelastic behaviour, providing a foundation for patient-specific simulations and real-time predictive tools in cardiovascular engineering.
- 19 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3331
Open AccessNew Multiscale Approach of Complex Modelling Chordae Tendineae Considering Strain-Dependent Modulus of Elasticity
Understanding the nonlinear mechanical behaviour of mitral valve chordae tendineae is critical for accurate biomechanical modelling in cardiac simulations. This study integrates high-resolution 3D finite element analysis with experimentally derived Cauchy stress–Green–Lagrange strain data to capture both material and geometric nonlinearities. A one-dimensional formulation incorporating strain-dependent elasticity and large deformation kinematics was developed and validated against 3D simulations in COMSOL Multiphysics. Calibrated using experimental stress–strain data and validated against high-fidelity 3D finite element simulations in COMSOL, it reveals that neglecting transverse deformation overestimates axial force by 7%. Cross-sectional area reduction during stretch remained consistently around 12%, underscoring the importance of Poisson effects. A polynomial fit to the strain-dependent modulus of elasticity enables efficient force prediction with excellent agreement to experimental data. These results advance the mathematical modelling of biological tissues with nonlinear hyperelastic behaviour, providing a foundation for patient-specific simulations and real-time predictive tools in cardiovascular engineering.
- Open Access
- 8 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5260
Discrete Element Simulations of Damage Evolution of NiAl-Based Material Reconstructed by Micro-CT Imaging
Sintered porous materials present challenges for any modeling approach applied to simulate their damage evolution because of their complex microstructure, which is crucial for the initialization and propagation of microcracks. This paper presents discrete element simulations of the damage evolution of a NiAl-based material reconstructed by micro-CT imaging. A novel geometry reconstruction procedure based on micro-CT images and the adapted advancing front algorithm fills the solid phase using well-connected irregular and highly dense sphere packing, which directly represents the microstructure of the porous material. Uniaxial compression experiments were performed to identify the behavior of the NiAl sample and validate the discrete element model. Discrete element simulations based on micro-CT imaging revealed a realistic representation of the damage evolution and stress–strain dependency. The stress and strain of the numerically obtained curve peak differed from the experimentally measured values by 0.1% and 4.2%, respectively. The analysis of damage evolution was performed according to the time variation rate of the broken bond count. Investigation of the stress–strain dependencies obtained by using different values of the compression strain rate showed that the performed simulations approached the quasi-static state and achieved the acceptable accuracy within the limits of the available computational resources. The proposed stress scaling technique allowed a seven times increase of the size of the time step, which reduced the computing time by seven times.
- 8 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5260
Open AccessDiscrete Element Simulations of Damage Evolution of NiAl-Based Material Reconstructed by Micro-CT Imaging
Sintered porous materials present challenges for any modeling approach applied to simulate their damage evolution because of their complex microstructure, which is crucial for the initialization and propagation of microcracks. This paper presents discrete element simulations of the damage evolution of a NiAl-based material reconstructed by micro-CT imaging. A novel geometry reconstruction procedure based on micro-CT images and the adapted advancing front algorithm fills the solid phase using well-connected irregular and highly dense sphere packing, which directly represents the microstructure of the porous material. Uniaxial compression experiments were performed to identify the behavior of the NiAl sample and validate the discrete element model. Discrete element simulations based on micro-CT imaging revealed a realistic representation of the damage evolution and stress–strain dependency. The stress and strain of the numerically obtained curve peak differed from the experimentally measured values by 0.1% and 4.2%, respectively. The analysis of damage evolution was performed according to the time variation rate of the broken bond count. Investigation of the stress–strain dependencies obtained by using different values of the compression strain rate showed that the performed simulations approached the quasi-static state and achieved the acceptable accuracy within the limits of the available computational resources. The proposed stress scaling technique allowed a seven times increase of the size of the time step, which reduced the computing time by seven times.
- Open Access
- 21 September 2017
- Published by Vilnius Gediminas Technical University in Mathematical Modelling and Analysis
- Vol. 22 (5) , 601-616
ON EFFICIENCY OF PARALLEL SOLVERS FOR THE BLOOD FLOW THROUGH AORTIC VALVE
Mathematical modelling of cardiac haemodynamics presents a great challenge to the computational scientists due to numerous numerical issues and required computational resources. In this paper, we study the parallel performance of 3D simulation software for the blood flow through the aortic valve. The fluid flow problem with the open aortic valve leaflets is formulated and solved in parallel. The choice between the segregated and coupled numerical schemes is discussed and investigated. We present and compare the parallel performance results of both types of parallel solvers. We investigate their strong and weak scalability.
- 21 September 2017
- Published by Vilnius Gediminas Technical University in Mathematical Modelling and Analysis
- Vol. 22 (5) , 601-616
Open AccessON EFFICIENCY OF PARALLEL SOLVERS FOR THE BLOOD FLOW THROUGH AORTIC VALVE
Mathematical modelling of cardiac haemodynamics presents a great challenge to the computational scientists due to numerous numerical issues and required computational resources. In this paper, we study the parallel performance of 3D simulation software for the blood flow through the aortic valve. The fluid flow problem with the open aortic valve leaflets is formulated and solved in parallel. The choice between the segregated and coupled numerical schemes is discussed and investigated. We present and compare the parallel performance results of both types of parallel solvers. We investigate their strong and weak scalability.