Zhihui Hong
Zhihui Hong has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haifeng Zhang
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
2 shared publications - Shiqiang Zheng
Beihang University
2 shared publications - Di Zhang
Beihang University
1 shared publication - Jianzhi Yang
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
1 shared publication - Minxia Shi
Beihang University
1 shared publication - Pengtao Tian
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
1 shared publication
Latest Publications
- 14 May 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (21)
Disturbance suppression based on LQR-CESO control strategy for demagnetization systems in magnetically shielded room
Magnetically shielded rooms (MSR) composed of high-permeability materials provided a near-zero magnetic environment for ultra-weak field measurements, such as biomagnetic cardiography and encephalography. To maximise material performance, a demagnetization current is applied to increase the effective permeability, thereby enhancing the shielding performance of the MSR. However, conventional open-loop demagnetization system is susceptible to disturbances that distort the current waveform and degrad the demagnetization effect. To improve disturbance suppression, this paper proposes a closed-loop demagnetization current control strategy that integrates linear quadratic regulator (LQR) with a cascaded extended state observer (CESO). The corresponding demagnetization current control (DCC) system is established on self-developed hardware. Considering the dynamic characteristics of the demagnetization current, the LQR is employed to balance control energy and tracking performance through optimal state feedback. Simultaneously, the CESO is introduced to estimate disturbances online and provide feedforward compensation. Experimental results demonstrated that the proposed LQR-CESO strategy effectively enhanced the disturbance suppression capability of the system. Compared with OPEN-LOOP, the average remanence in the center region of MSR was decreased by 28.8%, and the average shielding factor increased within the range of 1-10 Hz.
- 14 May 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (21)
Disturbance suppression based on LQR-CESO control strategy for demagnetization systems in magnetically shielded room
Magnetically shielded rooms (MSR) composed of high-permeability materials provided a near-zero magnetic environment for ultra-weak field measurements, such as biomagnetic cardiography and encephalography. To maximise material performance, a demagnetization current is applied to increase the effective permeability, thereby enhancing the shielding performance of the MSR. However, conventional open-loop demagnetization system is susceptible to disturbances that distort the current waveform and degrad the demagnetization effect. To improve disturbance suppression, this paper proposes a closed-loop demagnetization current control strategy that integrates linear quadratic regulator (LQR) with a cascaded extended state observer (CESO). The corresponding demagnetization current control (DCC) system is established on self-developed hardware. Considering the dynamic characteristics of the demagnetization current, the LQR is employed to balance control energy and tracking performance through optimal state feedback. Simultaneously, the CESO is introduced to estimate disturbances online and provide feedforward compensation. Experimental results demonstrated that the proposed LQR-CESO strategy effectively enhanced the disturbance suppression capability of the system. Compared with OPEN-LOOP, the average remanence in the center region of MSR was decreased by 28.8%, and the average shielding factor increased within the range of 1-10 Hz.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 15264-15273
Improving Information Collection Environment of Magnetocardiography Device Through Adaptive Interference Suppression Strategy
Multiple frequencies high-amplitude magnetic interference in the environment can adversely affect the detection of cardiac magnetic field signals inside magnetocardiography device. Adaptive multi-resonance control (AMR) is suitable for suppressing such interference, but the stability of active magnetic field compensation system (AMC) will be destroyed by the influence of the time delay of the sensor. To address this problem, this paper proposes a interference suppression method that combines an improved adaptive multi-resonance controller (IAMR) with proportional differential (PD) and linear extended state observer (LESO). Experimental results show that PD-LESO-IAMR can effectively suppress multiple frequencies magnetic interference under the premise of ensuring system stability. Compared with conventional PD-LESO, the average magnetic field interference in the MSC can be reduced from 3.73 pT to 1.80 pT, and the maximum anti-interference ability was increased by 50.25%.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 15264-15273
Improving Information Collection Environment of Magnetocardiography Device Through Adaptive Interference Suppression Strategy
Multiple frequencies high-amplitude magnetic interference in the environment can adversely affect the detection of cardiac magnetic field signals inside magnetocardiography device. Adaptive multi-resonance control (AMR) is suitable for suppressing such interference, but the stability of active magnetic field compensation system (AMC) will be destroyed by the influence of the time delay of the sensor. To address this problem, this paper proposes a interference suppression method that combines an improved adaptive multi-resonance controller (IAMR) with proportional differential (PD) and linear extended state observer (LESO). Experimental results show that PD-LESO-IAMR can effectively suppress multiple frequencies magnetic interference under the premise of ensuring system stability. Compared with conventional PD-LESO, the average magnetic field interference in the MSC can be reduced from 3.73 pT to 1.80 pT, and the maximum anti-interference ability was increased by 50.25%.