SQSébastien Quetin

Sébastien Quetin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sébastien Quetin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic catheter digitization in breast brachytherapy

    by Sébastien Quetin, Hossein Jafarzadeh, Jonathan Kalinowski, Hamed Bekerat, Boris Bahoric, Farhad Maleki, Shirin A. Enger

    Background: High dose rate (HDR) brachytherapy requires clinicians to digitize catheters manually. This process is time‐consuming, complex, and depends heavily on clinical experience–especially in breast cancer cases, where catheters may be inserted at varying angles and orientations due to an irregular anatomy. Purpose: This study is the first to automate catheter digitization specifically for breast HDR brachytherapy, emphasizing the unique challenges associated with this treatment site. It also introduces a pipeline that automatically digitizes catheters, generates dwell positions, and calculates the delivered dose for new breast cancer patients. Methods: Treatment data from 117 breast cancer patients treated with HDR brachytherapy were used. Pseudo‐contours for the catheters were created from the treatment digitization points and divided into three classes: catheter body, catheter head, and catheter tip. An nnU‐Net pipeline was trained to segment the pseudo‐contours on treatment planning computed tomography images of 88 patients (training and validation). Then, pseudo‐contours were digitized by separating the catheters into connected components. Predicted catheters with an unusual volume were flagged for manual review. A custom algorithm was designed to report and separate connected components containing colliding catheters. Finally, a spline was fitted to every separated catheter, and the tip was identified on the spline using the tip contour prediction. Dwell positions were placed from the created tip at a regular step size extracted from the DICOM plan file. Distance from each dwell position used during the clinical treatment to the fitted spline (shaft distance) was computed, as well as the distance from the treatment tip to the one identified by our pipeline. Dwell times from the clinical plan were assigned to the nearest generated dwell positions. TG‐43 dose in water was computed analytically, and the absorbed dose in the medium was predicted using a published AI‐based dose prediction model. Dosimetric comparison between the clinically delivered plan dose and the created automated plan dose was evaluated regarding dosimetric indices percent error. Results: Our pipeline was used to digitize 408 catheters on a test set of 29 patients. Shaft distance was on average and distance to the tip was on average . The dosimetric error between the manual and automated treatment plans was, on average, below 3% for planning target volume , , and for the lung, heart, skin, and chest wall and , in both water and heterogeneous media. For values in all the organs at risk, the average error remained below 5%. The pipeline execution time, including auto‐contouring, digitization, and dose to medium prediction, averages 118 s, ranging from 63 to 294 s. The pipeline successfully flagged all cases where digitization was not performed correctly. Conclusions: Our pipeline is the first to automate the digitization of catheters for breast brachytherapy, as well as the first to generate dwell positions and predict corresponding AI‐based absorbed dose to medium based on automatically digitized catheters. The automatically digitized catheters are in excellent agreement with the manually digitized ones while more accurately reflecting their true anatomical shape.


  • Bridging the Gap: Generalising State-of-the-Art U-Net Models to Sub-Saharan African Populations

    by Alyssa R. Amod, Alexandra Smith, Pearly Joubert, Confidence Raymond, Dong Zhang, Udunna C. Anazodo, Dodzi Motchon, Tinashe E. M. Mutsvangwa, Sébastien Quetin


  • Open Access

    Deep learning for high-resolution dose prediction in high dose rate brachytherapy for breast cancer treatment

    by Sébastien Quetin, Boris Bahoric, Farhad Maleki, Shirin A Enger

    Objective. Monte Carlo (MC) simulations are the benchmark for accurate radiotherapy dose calculations, notably in patient-specific high dose rate brachytherapy (HDR BT), in cases where considering tissue heterogeneities is critical. However, the lengthy computational time limits the practical application of MC simulations. Prior research used deep learning (DL) for dose prediction as an alternative to MC simulations. While accurate dose predictions akin to MC were attained, graphics processing unit limitations constrained these predictions to large voxels of 3 mm × 3 mm × 3 mm. This study aimed to enable dose predictions as accurate as MC simulations in 1 mm × 1 mm × 1 mm voxels within a clinically acceptable timeframe. Approach. Computed tomography scans of 98 breast cancer patients treated with Iridium-192-based HDR BT were used: 70 for training, 14 for validation, and 14 for testing. A new cropping strategy based on the distance to the seed was devised to reduce the volume size, enabling efficient training of 3D DL models using 1 mm × 1 mm × 1 mm dose grids. Additionally, novel DL architecture with layer-level fusion were proposed to predict MC simulated dose to medium-in-medium ( D m , m ). These architectures fuse information from TG-43 dose to water-in-water ( D w , w ) with patient tissue composition at the layer-level. Different inputs describing patient body composition were investigated. Main results. The proposed approach demonstrated state-of-the-art performance, on par with the MC D m , m maps, but 300 times faster. The mean absolute percent error for dosimetric indices between the MC and DL-predicted complete treatment plans was 0.17% ± 0.15% for the planning target volume V 100 , 0.30% ± 0.32% for the skin D 2 cc , 0.82% ± 0.79% for the lung D 2 cc , 0.34% ± 0.29% for the chest wall D 2 cc and 1.08% ± 0.98% for the heart D 2 cc . Significance. Unlike the time-consuming MC simulations, the proposed novel strategy efficiently converts TG-43 D w , w maps into precise D m , m maps at high resolution, enabling clinical integration.