WKWandee Khaimook

Wandee Khaimook

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wandee Khaimook has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Intratympanic Sodium Thiosulfate Gel Injection to Prevent Cisplatin‐Induced Ototoxicity

    by Kunyakorn Vittayakoonsakulchai, Pittayapon Pitathawatchai, Yuvatiya Plodpai, Viraporn Atchariyasathian, Wandee Khaimook, Virat Kirtsreesakul, Rungarun Kittichet, Pattarawadee Prayuenyong

    Objective: This study aimed to evaluate the efficacy and safety of intratympanic sodium thiosulfate (STS) gel injection in preventing cisplatin‐induced hearing loss. Methods: We conducted a single‐blinded randomized controlled trial, enrolling adults with head and neck cancer undergoing cisplatin chemotherapy. Intratympanic STS gel was injected into one ear within 3 h before each cisplatin cycle, while the contralateral ear served as a control. Clinical and audiometric assessments were performed before each injection and 1–3 months after the completion of chemotherapy. Changes in hearing thresholds from baseline at each frequency were measured. Ototoxicity was defined according to the American Speech‐Language‐Hearing Association (ASHA) criteria. Adverse events associated with intratympanic STS gel injections were also monitored. Results: Twenty‐eight patients were included in the study. Based on ASHA criteria within the frequency range of 0.25–8 kHz, there was no statistically significant difference in the incidence of ototoxicity between the treated and control ears ( p = 0.683). Compared with control ears, treated ears exhibited significantly reduced threshold shifts from baseline in the 4, 6, 8, 9, and 11 kHz, with mean differences of approximately 7–10 dB. A safety analysis of 74 injections revealed minor adverse effects, including otalgia (10.8%), transient vertigo (10.8%), dizziness (14.8%), and tympanic membrane perforation (4.0%). Conclusion: Our findings showed no significant difference in the incidence of cisplatin ototoxicity between STS injected and control ears. Nonetheless, intratympanic STS gel injections demonstrated potential benefits in preserving hearing at high and extended‐high frequencies. The procedure was generally well‐tolerated, with manageable adverse effects. Level of Evidence: N/A.

  • Open Access

    Noise-induced Hearing Loss Among Dental Personnel in a University Hospital: Occupational Noise Exposure and Lifestyle Factors — A Cross-sectional Analytical Study

    by Thitiworn Choosong, Sittichok Teawanan, Ramida Dindamrongkul, Wandee Khaimook, Sasithorn Srimeechai, Paranicha Bunruang, Phattaranun Phiboon, Wannadee Wacharachaipong


  • Accuracy of the mobile application-based audiometry for screening hearing loss

    by Ramida Chuenchavalit, Ramida Dindamrongkul, Pattarawadee Prayuenyong, Wandee Khaimook

    Purpose To evaluate the accuracy of the mobile application compared to that of conventional audiometry for screening hearing loss. Methods This cross-sectional study was conducted in the tertiary hospital between July 2023 and October 2024. A total of 200 participants, aged 18–65 years, who underwent conventional audiometry were included in the study. Each participant also completed a hearing test using a mobile application on a 9th-generation iPad in a quiet room. Mean differences in pure tone threshold (PTT) and pure tone average between conventional audiometry and the mobile application were analysed using a paired t-test. A Bland–Altman plot was used to assess agreement in PTT measurements between the two methods. The accuracy, sensitivity, and specificity of the mobile application were also calculated. Results The mobile application demonstrated an overall accuracy of 81.5% in distinguishing between normal and abnormal hearing. A strong correlation was observed between thePTTs of the two methods at 4, 6, and 8 kHz. Sensitivity and specificity were PTTs of the two methods at 4, 6, and 8 kHz. Sensitivity and specificity were particularly high at these frequencies. The results indicated both systematic and random errors; however, after correction for mean differences, sensitivity improved while maintaining high specificity. Conclusion The Ear Test application demonstrated high accuracy in evaluating hearing thresholds at high frequencies but presented limitations at lower frequencies. These findings suggest its potential for screening sensorineural hearing loss, particularly at high frequencies. Further development of the application is recommended to address systemic errors.

  • Open Access

    Impact of ototoxic agents and noise exposure on hearing loss among healthcare personnel in a medical university: a cross-sectional analytical study

    by Thitiworn Choosong, Sasithorn Srimeechai, Ramida Dindamrongkul, Wandee Khaimook

    Background: Ototoxic agents, such as xylene, formaldehyde, mercury, and antineoplastic agents, are routinely used in hospitals. Studies on hearing loss (HL) among healthcare workers (HCWs) exposed to ototoxic agents and noise remain limited in Thailand. In this study, we aimed to investigate the combined effects of low-level occupational noise and ototoxic agent exposure and evaluate the prevalence of HL among HCWs. Methods: This cross-sectional analytical study was conducted at a university hospital in Thailand between December 2022 and October 2023. Ototoxic exposure was assessed using self-reported data verified by the researchers. Occupational noise exposure levels were measured using a dosimeter, and HL was evaluated using audiometry. Multiple regression analysis was performed to identify factors associated with HL. Results: Of 169 participants who underwent audiometric tests, 17.2% (29/169 participants) had HL, with 20.3% (16/79 exposed) in the exposed group and 14.4% (13/90 unexposed) in the non-exposed group ( p > 0.05). HCWs exposed to antineoplastic drugs and those working in the pharmacy department demonstrated the highest mean noise levels (75.20 ± 3.94 dBA and 77.68 ± 3.81 dBA, respectively). Furthermore, the average number of elevated unweighted peak noise events was observed in the pharmacy (232.89 ± 88.66 events) and emergency (230.96 ± 60.56 events) departments. Age, sex, and obesity were significantly associated with HL. Conclusions: A high prevalence of HL was observed among HCWs despite low noise exposure levels, underscoring the substantial impact of combined exposure to occupational noise and ototoxic agents. The identification of groups that are particularly vulnerable to antineoplastic drugs, such as HCWs, guides targeted preventive measures and further research in this area.


  • Open Access

    Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker

    by Ramida Dindamrongkul, Thitiworn Choosong, Wandee Khaimook

    Background: Occupational hearing loss (OHL) is a primary concern in industrial settings. In hospitals, the healthcare workers are also exposed to noise and chemical agents, the reported hearing loss in this occupation is underestimated. Hearing examination is routinely evaluated in the range of conventional frequencies, which may not detect hearing problems early. Therefore, this study aimed to reveal the hearing thresholds among medical personnel exposed to loud noise and/or chemical environments, estimating the prevalence of hearing loss using four different audiological methods. Methods: One hundred and thirty-one medical personnel were recruited from different units at the same hospital and grouped into noise, chemical, and mixed exposure categories. The hearing thresholds were assessed using four audiological methods, conventional audiometry (CA), extended high-frequency audiometry (EHFA), standard frequency distortion product otoacoustic emission (DPOAE), and ultra-high-frequency DPOAE. Statistical analyses were performed using R. Results: Ultra-high-frequency DPOAE and EHFA showed a higher prevalence of hearing loss than CA and DPOAE. Even CA usually demonstrated hearing threshold within normal limits, this study found a notch audiogram pattern indicating a decline in hearing loss over time at frequencies of 2, 3, and 4 kHz in each age group and a sign at a frequency of 6 kHz. Conclusions: Evidence of hearing loss can be identified with ultra-high-frequency DPOAE and EHFA, despite conventional audiometry indicating normal hearing thresholds.


  • Accuracy of otoacoustic emissions, and automated and diagnostic auditory brainstem responses, in high-risk infants

    by W Khaimook, D Pantuyosyanyong, P Pitathawatchai

    Objectives: This study aimed to compare the diagnostic reliabilities of transient evoked otoacoustic emissions, automated auditory brainstem responses and brainstem auditory evoked responses for detecting hearing loss, and to use the information regarding hearing level of automated auditory brainstem responses for planning rehabilitation.Methods: A total of 144 high-risk infants (288 ears) completed the 3 hearing tests. The sensitivity and specificity of otoacoustic emissions and automated auditory brainstem responses were compared using the chi-square test.Results: Automated auditory brainstem response was the most reliable test of hearing levels, with a sensitivity of 91.7 per cent and specificity of 92.1 per cent; the sensitivity of otoacoustic emissions was 78.7 per cent and the specificity was 88.8 per cent.Conclusion: Automated auditory brainstem responses have acceptably high sensitivity and specificity. Additionally, the hearing level from automated auditory brainstem responses can help the screeners explain to the parents the importance of further diagnosis and rehabilitation.


    • 1 December 2011
      • Vol. 94  (12) , 1495-9

    Therapy of idiopathic sudden sensorineural hearing loss with intratympanic steroid injection.

    by Wandee Khaimook, Kitti Jantarapattana

    To evaluate the efficacy of intratympanic steroid injection in patients with idiopathic sudden sensorineural hearing loss (SSNHL) who are not responding to systemic steroids. A prospective cohort study of 31 patients, with idiopathic SSNHL refractory to oral steroid therapy, who were treated with intratympanic steroid injection. The injections were performed once a week for three consecutive weeks. Pure tone audiometry (PTA) and speech discrimination score (SDS) was performed before and two months after intratympanic steroid injection had been completed. Successful treatment was defined as a decrease in PTA by 10 dB or more, or an increase in SDS by 20% or more. Thirty-one patients were treated with intratympanic steroid injection, 22 women and 9 men. The average age was 53 years. Overall success was 14 patients (45.2%). Eleven of the patients (35.5%) showed either improvement in PTA or SDS, among these there were two patients who had improvement in only PTA and nine patients had improvement only in SDS. Besides, three of the patients (9.7%) had improvement in both PTA and SDS. Intratympanic steroid injection effectively improves hearing in patients with SSNHL after treatment failure with oral systemic steroid and is not associated with side effects. Therefore, it can be used as salvage therapy after failed conventional treatment. Further studies are required to consider whether intratympanic steroid injection might be used as the first line treatment in SSNHL.