    Prediction of Weather Element Sensor Values on Digital Surface Weather Observation Equipment with Artificial Intelligence

    by Sandi Ronggo Panji, Agus Sofwan

    Peralihan penggunaan peralatan pengamatan cuaca digital telah meningkatkan efisiensi, namun juga menimbulkan tantangan baru terkait akurasi sensor serta keandalan data. Penelitian ini bertujuan mengembangkan model prediksi untuk nilai sensor suhu udara (T), kelembaban udara (RH), dan tekanan udara (P) dengan mengaplikasikan Artificial Neural Network (ANN) algoritma backpropagation. Data yang digunakan merupakan data pengamatan cuaca digital interval 1 menit yang berasal dari Stasiun Meteorologi Kelas III Fatmawati Soekarno, Bengkulu. Arsitektur yang digunakan pada model ANN terdiri dari atas dua hidden layer yang dioptimalkan melalui proses pelatihan dan validasi. Kinerja model dievaluasi dengan menggunakan koefisien korelasi (R), Root Mean Square Error (RMSE), dan Mean Absolute Percentage Error (MAPE). Penelitian menunjukkan bahwa model suhu udara dan kelembaban udara memiliki tingkat korelasi tinggi (R > 0,94) dengan nilai RMSE dan MAPE yang rendah. Sementara itu, model tekanan udara, meskipun memiliki korelasi sedang (R ~0,56), mampu memberikan prediksi dengan tingkat presisi yang sangat tinggi (MAPE ~0,09%). Pengujian pada pada model prediksi menunjukkan bahwa model yang telah dibangun mampu mempertahankan kinerja dengan baik. Hasil ini menunjukkan bahwa model ANN dapat digunakan untuk mendukung operasional dalam pemantauan kondisi cuaca secara real-time serta dapat digunakan dalam mendukung keandalan data pengamatan cuaca digital.


  • Open Access

    Perancangan Lightning Mast Protection (LMP) Area Berbahaya Menggunakan Metode Rolling Sphere pada Tangki Penyimpanan Petrokima di Cilegon

    by Agus Sofwan, Asept Harri Nugroho

    Sistem proteksi petir pada tangki-tangki berisikan petrokimia di wilayah pantai Cilegon termasuk dalam kategori area berbahaya, yang merupakan cairan petrokimia mudah terbakar. Wilayah pantai Cilegon ketinggian 13 mdpl, dengan kerapatan petir yang tinggi frekuensi sambaran 150 – 200 kali per hari. Salah satu tangki di area Plant 2 mengalami kebakaran akibat sambaran petir, berpotensi menimbulkan kerusakan konstruksi bangunan, kebakaran, intervensi peralatan elektronik, hingga kematian. Analisis dan evaluasi desain proteksi petir pada tangki tersebut dilakukan dengan metode proteksi petir menggunakan rolling sphere dengan simulasi software AutoCAD 2D. Desain Lightning Protection System LPS harus memenuhi SNI 03-7015-2004 tentang proteksi petir dan IEC 62305-2 manajemen risiko serta kerusakan fisik pada struktur dan bahaya bagi kehidupan. Radius proteksi ditentukan menggunakan metode rolling sphere. Area berbahaya, desain menggunakan LPS level II radius proteksi 30 meter dan arus puncak petir minimum 5 kA. Pada tangki tipikal 1 diameter < 28 meter, 3 unit air terminal setinggi 4,5 meter, radius proteksi 15,941 meter, sudut lindung sisi luar 40O, dan sisi atap 64 O. Pada tangki tipikal 2, diameter > 28 meter, 4 titik air terminal tinggi 6 meter di sekeliling atap serta 1 unit air terminal tinggi 5 meter di tengah atap. Down conductor badan tangki, radius proteksi 13,794 meter menyerupai lingkaran, sudut lindung sisi luar tangki 28O, sisi atap 64O, dan sudut lindung air terminal di tengah tangki sebesar 48O. Tangki tipikal 2 tipe floating roof, maka bypass conductor harus dipasang. Desainproduk komponen lightning protection air terminal dan asesoris koneksi brand Dehn sertifikasi type test IEC 62305, menghasilkan nilai yang cukup signifikan untuk sistem proteksi petir. Kata Kunci: LPS , tangki petrokima, area berbaya, rolling sphere, IEC 62305, radius proteksi.

  • Open Access

    Data Center Room Monitoring Based on Temperature and Humidity with Internet of Things

    by M. Asep Rizkiawan, Harry Ramza, Nuroji Nuroji, Agus Sofwan

    The idea of the Internet of Things (IoT) encompasses the application of technologies such as sensors and software to an object for the purpose of communicating, controlling, connecting, and exchanging data with other devices while connected to the Internet. In this study, the IoT concept developed was used to monitor and regulate conditions within the data center. The development method used is the life cycle method of system development. The development process involved modifying the Arduino Uno with an esp8266 microcontroller and a DHT-22 sensor to detect temperature and humidity in real time. The testing of IoT development was done using the black box and white box methods. Research results show that the prototyped IoT network can operate well and successfully improve data center performance. In addition, users can also access the system through websites and mobile applications to facilitate the monitoring process.


  • Open Access

    Penerapan Metode Kalman Filter Slow-Fast Differential Untuk Meningkatkan Kerapatan Dan Nilai Curah Hujan Dengan Menggunakan Signal To Noise Ratio Pada Hub VSat

    by Toto Andrianto, Agus Sofwan, Kun Wardhana, Masbah R.T Siregar

    Rainfall measurement must be carried out, because rain is an essential phenomenon for human living. Generally, rainfall is measured using ground measurement (rain gauge), weather radar, and weather satellite. In this study, we exploit the potential of estimating rain fall by down SNR Ku-Band (14 GHz) wave on VSAT Hub using slow-fast differential kalman filter. This method using two kalman filters, ST (Slow Tracker) and FT (Fast Tracker). ST is slower, not more reactive than FT. Combination of those filters can detect and estimate rainfall. Rainfall estimation obtained from down SNR will be compared with rainfall measurement from ground measurement of rain gauge. Hub and rain gauge are close together and located in Kemayoran, Jakarta Pusat. This Area is still in coverage area of rain gauge between 250 m2 and 3000 m2. This research was successful in detecting ongoing rain. The rainfall estimation results obtained had a correlation coefficient of 0.9648 and a root mean square error of 4.418 Key words: Rain fall, Ku-band, signal to noise ratio, slow-fast differential kalman filter

  • Open Access

    Automation System For Water Leakage Detection With PLC Omron and Arduino Uno and HMI NB10-TW01 Direct Digital Bit 8 Binary I/O

    by Desmayadi Desmayadi, Taswanda Taryo, Agus Sofwan, Sri Vidawati

    There are many challenges in operating a multi-story building so the building can operate well. One potential problem that has a serious risk of damaging assets and even causing disruption to building operations is water leaks. To detect the impact of leaks from water installations, a detection system is needed that can provide specific information about the location of the leak to the building control center. This system uses a water detector as detection and a digital direct bit module as 8-bit input to the PLC Omron CPM2A, then the PLC will send an 8-bit digital direct output signal to the Arduino Uno module and a graphic visualization display using the Omron NB10-TW001 HMI. This research method is to design hardware and software. Testing the accuracy of input and output (I/O) signals, testing detectors, power supplies, and relay modules. From the research results, it was found that the input and output signals correspond to the 8 I/O bits, namely 00000000 - 11111111 which are processed by the PLC and Arduino, the performance of the Water Detector functions well as proven by the functioning of the CRM. Keyword: Programmable Logic Controller (PLC); Water Detector (WD); Channel Relay Module (CRM); Human Machine Interface (HMI); Arduino Uno; Digital Direct Bit.

  • Open Access

    Desain Dan Realisasi Bandpass Filter 5G Rejection Bandpass Filter Pada Frekuensi 3,7 - 4,2 Ghz

    by Parlaungan Nasution, Iwan Krisnadi, Agus Sofwan

    Fifth Generation, commonly referred to as 5G Technology, is an advanced technology from 4G. 5G technology is considered an effective technology to support the ongoing IoT era and also industry 4.0. The 5G wireless network standard has evolved into the most advanced technology today. Some who have adopted 5G technology include Smart Cities, Internet of Things (IoT). Internet of Things (IoT) and Machine to Machine (M2M) communications on a large scale will utilize the 5G wireless system, so that various requirements will be determined on the network regarding device cost, reliability, energy consumption, latency, and so on. The development of 5G networks is based on New Radio (NR) technology developed by 3GPP as a guide for interfaces to 5G technology. The 5G network system is built quantitatively with the performance parameters determined by ITU-R on 5G technology through IMT-2020. Development of 5G network systems according to future needs and services. The mid-band frequency that will be proposed for the use of the 5G technology frequency is at 3.5 GHz, but this frequency is also used by several satellite communication system operators in Indonesia. Based on the results of the 2019 World Radio Congress, Indonesia received a frequency range of 3500 – 3600 MHz for IMT-Systems (including 5G technology). In fact, based on research conducted by the GSMA, most countries in the Southeast Asian region use the 3400 – 3700 MHz frequency range for the use of satellite communication systems. The trial 5G Frequency Band is n78 (3GPP), namely 3400-3600 MHz, while the current Frequency Band is FSS Ext C-band and C-band, namely 3400-4200 The results of this bandpass filter can pass signals at a frequency of 3.7-4.2 GHz and has a bandwidth of 38 MHz, has a VSWR of 1.28, insertion loss of -3.76 dB and return loss of - 28.293 dB Keywords : 5G, C Band, Bandpass filter

  • Open Access

    Internet of Things (IoT) Based Temperature and Humidity Detector Prototype in the UHAMKA Data Center Room

    by M. Asep Rizkiawan, Harry Ramza, Agus Sofwan

    Internet of Things (IoT) is a concept where an object or entity is imbued with technology such as sensors and software, aiming to communicate, control, connect, and exchange data with other devices as long as they remain connected to the internet. In this research, the developed IoT is employed to monitor and control the conditions of a data center space. The research methodology follows the system development life cycle, utilizing the Blynk application and a modified Arduino Uno with the esp8266 microcontroller, relay, and DHT-22 sensor for real-time temperature and humidity detection. The IoT development's outcomes were tested through black box and white box approaches. The research results demonstrate that the IoT network prototype functions effectively, enhancing the performance of the data center space. Temperature measurements were acquired from the DHT22 sensor, and alternative temperature measurements were taken without utilizing the DHT22 sensor, instead using a tool known as a thermometer, revealing measurement errors. Based on the calculation of the average percentage of temperature error on the DHT22 sensor, it can be concluded that the temperature error rate reaches 0.051%, while for humidity it reaches 0.064%, with an average delay time of 6.542 ms. Additionally, users have convenient access through both a website and mobile platform for seamless monitoring.


  • Open Access

    ANALISIS SUSUT UMUR TRANSFORMATOR AKIBAT BEBAN LEBIH DENGAN PENAMBAHAN TRANSFORMATOR DISTRIBUSI SISIPAN

    by A. Sofwan, R. Dayang Tias, N. Lubis

    Jika transformator dibebani di atas 80 % secara terus menerus dalam waktu yang lama maka akan meningkatkan susut umurnya. Hal ini disebabkan karena peningkatan suhu hot spot minyak trafo distribusi yang dipengaruhi oleh kenaikan beban. Transformator diharapkan dapat beroperasi selama 30 tahun. Di PLN Rayon Lubuk Basung terdapat 2 transformator dengan beban >80 %, yaitu transformator A dan transformator B. Untuk menghindari terjadinya penyusutan umur pakai 2 buah transformator tersebut maka dilakukan penambahan transformator sisipan (transformator C) pada feeder yang sama. Kelebihan beban 27 % pada transformator A dan 31 % pada transformator B dipindahkan ke transformator C. Sehingga transformator C sekarang dibebani 58 % dari kapasitas daya pengenalnya. Beban transformator A dan B yang dipindahkan tersebut tidak boleh melebihi 80% dari kapasitas daya pengenal transformator C (50 kVA). Setelah dilakukan penambahan transformator distribusi sisipan beban transformator distribusi A yang tadinya 81% sekarang berkurang menjadi 48%, dan transformator distribusi B yang tadinya 84% sekarang berkurang menjadi 47%. Selain beban yang berkurang, susut umur transformator distribusi A juga berkurang dari 3,3 tahun menjadi 0,13 tahun begitupun dengan susut umur transformator distribusi B juga berkurang dari 5 tahun menjadi 0.13 tahun.


  • Open Access

    SYSTEM MONITORING PARAMETER UTAMA PADA RUANGAN KERJA TRANSFORMATOR DENGAN BANTUAN KOMPUTER

    by A. Sofwan, M.G. Prasetyo

    Makalah ini memaparkan tentang konsep Sistem monitoring kondisi ruangTransformator dengan bantuan komputer. Dua parameter utama kondisi ruang transformatorini adalah suhu dan kelembaban. Dengan sistem monitoring ini dimaksudkan untukmembantu mengontrol dan memonotoring suhu kerja ruangan pada transformator, dimanapada aplikasinya digunakan ruangan tetutup. Pada sistem monitoring dan kelembaban inimenggunakan komponen utama yaitu : SHT 11 sebagai sensor suhu dan kelembaban, max232 sebagai serial koneksi, ATmega 8 sebagai kontrol program dan akuisisi data dandigunakan komputer serta aplikasi utama Borland Delphi 7 sebagai sarana program Visual.Dalam pengujian monitoring suhu operasi ruangan transformator antara 290C sampai 330Cdan kelembaban antara 67%RH sampai 56%RH, didapatkan hasil eror rata-rata darikeempat pengujian, eror program Low level pada kelembaban adalah 0,805% dan untukpembacaan temperatur error oleh program low level dengan error rata-rata 0,07%. Programlow level language tidak berpengaruh terhadap kemampuan sensor SHT11.