Mykola Yefremov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mykola Yefremov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Iurii Krak
Taras Shevchenko National University of Kyiv
4 shared publications - A. V. Liashko
Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
2 shared publications - Andrey Liashko
Київський національний університет ім. Тараса Шевченка, Київ, Україна
2 shared publications - Oleg Stelia
Taras Shevchenko National University of Kyiv
2 shared publications - Bogdan Batsak
National Scientific Center «M.D. Strazhesko Institute of Cardiology, Clinical and Regenerative Medicine» of NAMS ofUkraine, Kyiv, Ukraine
1 shared publication - Oleg Stelia
Laboratory of Communicative Information Technologies, V.M. Glushkov Institute of Cybernetics, Kyiv, Ukraine, Ukraine
1 shared publication
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Preprints.org
Resource-Efficient Edge Framework for Real-Time ECG Processing and R-Peak Detection on 8-Bit Microcontrollers
The expansion of the Internet of Medical Things (IoMT) has increased the demand for real-time electrocardiogram (ECG) monitoring on wearable devices. However, implementing signal processing on ultra-low-power edge nodes is constrained by hardware limitations, specifically the absence of a Floating-Point Unit (FPU) and restricted SRAM capacity. This paper presents a resource-efficient framework for real-time R-peak detection optimized for 8-bit microcontrollers. The core component is a piecewise-polynomial smoothing algorithm based on Hermite splines, integrated directly into the ADC sampling loop. To maintain signal integrity under motion artifacts, a cascading filtering architecture is employed, operating on fixed-size frame buffers with a peak memory footprint of approximately 2.3 KB. Detection performance was evaluated on physical hardware signals (AD8232/ATmega2560) recorded during rest and physical activity, while reference recordings from the MIT-BIH Arrhythmia Database served as a morphological reference. Statistical analysis using ensemble averaging and point-wise confidence intervals (96% confidence level, D = 2.05) confirmed that the filtering process suppresses quantization noise and myographic artifacts without distorting the physiological morphology of the ECG. Experimental evaluation demonstrated a sensitivity (SEN) of 94.67–99.83%, a positive predictive value (PPV) of 99.30–100%, and a mean F-score of 98.95%. Extracting and transmitting metadata (RR intervals) instead of raw signal samples reduces network traffic and overall power consumption in autonomous edge-based cardiac monitoring nodes.
- 19 October 2026
- Published by MDPI AG in Preprints.org
Open AccessResource-Efficient Edge Framework for Real-Time ECG Processing and R-Peak Detection on 8-Bit Microcontrollers
The expansion of the Internet of Medical Things (IoMT) has increased the demand for real-time electrocardiogram (ECG) monitoring on wearable devices. However, implementing signal processing on ultra-low-power edge nodes is constrained by hardware limitations, specifically the absence of a Floating-Point Unit (FPU) and restricted SRAM capacity. This paper presents a resource-efficient framework for real-time R-peak detection optimized for 8-bit microcontrollers. The core component is a piecewise-polynomial smoothing algorithm based on Hermite splines, integrated directly into the ADC sampling loop. To maintain signal integrity under motion artifacts, a cascading filtering architecture is employed, operating on fixed-size frame buffers with a peak memory footprint of approximately 2.3 KB. Detection performance was evaluated on physical hardware signals (AD8232/ATmega2560) recorded during rest and physical activity, while reference recordings from the MIT-BIH Arrhythmia Database served as a morphological reference. Statistical analysis using ensemble averaging and point-wise confidence intervals (96% confidence level, D = 2.05) confirmed that the filtering process suppresses quantization noise and myographic artifacts without distorting the physiological morphology of the ECG. Experimental evaluation demonstrated a sensitivity (SEN) of 94.67–99.83%, a positive predictive value (PPV) of 99.30–100%, and a mean F-score of 98.95%. Extracting and transmitting metadata (RR intervals) instead of raw signal samples reduces network traffic and overall power consumption in autonomous edge-based cardiac monitoring nodes.
- 1 August 2026
- Published by Springer Nature in Cybernetics and Systems Analysis
- Vol. 62 (4) , 690-700
Accurate R-Peak Detection in Electrocardiograms: Piecewise Polynomial Approximation, Noise Reduction, and First-Derivative Analysis
- 1 August 2026
- Published by Springer Nature in Cybernetics and Systems Analysis
- Vol. 62 (4) , 690-700
Accurate R-Peak Detection in Electrocardiograms: Piecewise Polynomial Approximation, Noise Reduction, and First-Derivative Analysis
- 22 January 2026
- Published by National Aerospace University - Kharkiv Aviation Institute in RADIOELECTRONIC AND COMPUTER SYSTEMS
- Vol. 2026 (1) , 22-34
An efficient threshold method for detecting R-peaks in electrocardiogram
Automated R-peak detection in electrocardiogram (ECG) signals is essential to heart rhythm analysis, with applications in heart rate monitoring, heart rate variability (HRV) assessment, arrhythmia diagnosis ets. Its accuracy, however, is highly sensitive to noise and artifacts present in the ECG recording. The study proposes a method and its software implementation for R-peak detection, based on signal smoothing followed by differentiation and the application of a thresholding approach. The method is designed for use in resource-constrained environments, such as portable and embedded monitoring systems. The objective of the study is to develop a computationally efficient and accurate method for the automatic detection of R-peaks in ECG signals, tailored to a personalized patient approach. The primary focus is on robustness to noise and QRS complex morphology, as well as the algorithm’s ability to operate under limited computational resources and in real-time conditions. The proposed method relies on staged ECG signal processing. To validate the approach and compare its effectiveness, existing studies in the field were analysed. The subject of the study involves processing ECG signals and addressing challenges in R-peak detection in ECGs recorded via Holter monitors by constructing a smoothed continuous signal based on discrete data obtained during digitization. The discrete nature of the initial signal complicates differentiation and the precise identification of characteristic points, specifically R-peaks, which play a crucial role in diagnosing cardiac conditions. The scientific novelty of this investigation lies in the use of a second-order piecewise polynomial approximation to represent the ECG signal. This approach enables noise reduction in the signal and represents the discrete signal as a continuous function together with its first derivative, thereby permitting the analytical computation of its derivative. Results involve the detection of R-peaks by analysing the derivative of the smoothed signal: regions with sharp changes characteristic of the QRS complex were identified, and an iterative smoothing scheme was developed, with the number of iterations determined by a proposed stopping criterion. The proposed method was implemented in software and tested on data from the open-access MIT-BIH Arrhythmia Database, which includes over 60 recordings and more than 100,000 annotated R-peaks. The results were compared with studies by other authors using the metric, based on standard precision and sensitivity metrics. Conclusions: The study proposes an effective and adaptive approach to ECG signal processing, ensuring reliable R-peak detection under conditions of significant noise, baseline drift, and physiological variability across patients. The obtained results demonstrated high performance metrics: up to 99.5% (average above 99.1%), consistently exceeding 99%, and in some recordings reaching 100%. Thus, the proposed approach is competitive, demonstrating high accuracy in detecting R-peaks in cases of arrhythmias, peak inversions, non-standard QRS complex morphology, and other challenging signal conditions. The study’s results can be applied in ECG analysis practice, particularly in the development of automated diagnostic systems or signal preprocessing before the application of classification methods.
- 22 January 2026
- Published by National Aerospace University - Kharkiv Aviation Institute in RADIOELECTRONIC AND COMPUTER SYSTEMS
- Vol. 2026 (1) , 22-34
An efficient threshold method for detecting R-peaks in electrocardiogram
Automated R-peak detection in electrocardiogram (ECG) signals is essential to heart rhythm analysis, with applications in heart rate monitoring, heart rate variability (HRV) assessment, arrhythmia diagnosis ets. Its accuracy, however, is highly sensitive to noise and artifacts present in the ECG recording. The study proposes a method and its software implementation for R-peak detection, based on signal smoothing followed by differentiation and the application of a thresholding approach. The method is designed for use in resource-constrained environments, such as portable and embedded monitoring systems. The objective of the study is to develop a computationally efficient and accurate method for the automatic detection of R-peaks in ECG signals, tailored to a personalized patient approach. The primary focus is on robustness to noise and QRS complex morphology, as well as the algorithm’s ability to operate under limited computational resources and in real-time conditions. The proposed method relies on staged ECG signal processing. To validate the approach and compare its effectiveness, existing studies in the field were analysed. The subject of the study involves processing ECG signals and addressing challenges in R-peak detection in ECGs recorded via Holter monitors by constructing a smoothed continuous signal based on discrete data obtained during digitization. The discrete nature of the initial signal complicates differentiation and the precise identification of characteristic points, specifically R-peaks, which play a crucial role in diagnosing cardiac conditions. The scientific novelty of this investigation lies in the use of a second-order piecewise polynomial approximation to represent the ECG signal. This approach enables noise reduction in the signal and represents the discrete signal as a continuous function together with its first derivative, thereby permitting the analytical computation of its derivative. Results involve the detection of R-peaks by analysing the derivative of the smoothed signal: regions with sharp changes characteristic of the QRS complex were identified, and an iterative smoothing scheme was developed, with the number of iterations determined by a proposed stopping criterion. The proposed method was implemented in software and tested on data from the open-access MIT-BIH Arrhythmia Database, which includes over 60 recordings and more than 100,000 annotated R-peaks. The results were compared with studies by other authors using the metric, based on standard precision and sensitivity metrics. Conclusions: The study proposes an effective and adaptive approach to ECG signal processing, ensuring reliable R-peak detection under conditions of significant noise, baseline drift, and physiological variability across patients. The obtained results demonstrated high performance metrics: up to 99.5% (average above 99.1%), consistently exceeding 99%, and in some recordings reaching 100%. Thus, the proposed approach is competitive, demonstrating high accuracy in detecting R-peaks in cases of arrhythmias, peak inversions, non-standard QRS complex morphology, and other challenging signal conditions. The study’s results can be applied in ECG analysis practice, particularly in the development of automated diagnostic systems or signal preprocessing before the application of classification methods.
- Open Access
- 1 December 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in PROBLEMS IN PROGRAMMING
- No. 4,p. 43-50
Software solution for electrocardiogram storage and analysis
Software solutions for medical and healthcare fields are becoming increasingly popular due to advancements in information technology. Over the past decades peak detection algorithms as well as detection of other segments on ECG, arrhythmias detection and other pathologies detection algorithms achieved significant accuracy. This study proposes an approach for integrating such algorithms into a unified systems by developing a software solution that analyzes available ECGs from various sources, standardizes them into a common format, and provides detailed reporting that is easily understandable for medical experts or patients. The implementation is carried out as a web application that can provide users with information about cardiograms, process ECGs depending on the integrated algorithms, store necessary ECG segments, diagnostic results, and more. The system incorporates a newly developed algorithm for detecting R-peaks and visualizing ECG signals processed by the algorithm with annotations obtained both automatically and with the participation of cardiology specialists.
- 1 December 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in PROBLEMS IN PROGRAMMING
- No. 4,p. 43-50
Open AccessSoftware solution for electrocardiogram storage and analysis
Software solutions for medical and healthcare fields are becoming increasingly popular due to advancements in information technology. Over the past decades peak detection algorithms as well as detection of other segments on ECG, arrhythmias detection and other pathologies detection algorithms achieved significant accuracy. This study proposes an approach for integrating such algorithms into a unified systems by developing a software solution that analyzes available ECGs from various sources, standardizes them into a common format, and provides detailed reporting that is easily understandable for medical experts or patients. The implementation is carried out as a web application that can provide users with information about cardiograms, process ECGs depending on the integrated algorithms, store necessary ECG segments, diagnostic results, and more. The system incorporates a newly developed algorithm for detecting R-peaks and visualizing ECG signals processed by the algorithm with annotations obtained both automatically and with the participation of cardiology specialists.
- Open Access
- 24 October 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Reports of the National Academy of Sciences of Ukraine
- No. 5,p. 44-52
Інформаційна технологія обробки даних електрокардіограм для знаходження R-піків
Запропоновано підхід до коректного обчислення похідної сигналу електрокардіограми (ЕКГ) для ефективного визначення R-піків на основі порогових алгоритмів. На відміну від існуючих порогових підходів з використанням обчислення похідної сигналу ЕКГ, даний підхід має істотні удосконалення в напрямку оптимізації обчислень, що дозволяє використовувати його для великих наборів даних. Новизна підходу полягає в тому, що для даних ЕКГ будується кусково-поліноміальне наближення, яке водночас є згладжуючим. Надалі обчислюється похідна від згладженої функції. Ефективність методу підтверджена за допомогою розробленої інформаційної технології для обчислення R-піків ЕКГ з відкритої бази MIT-BIH.
- 24 October 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Reports of the National Academy of Sciences of Ukraine
- No. 5,p. 44-52
Open AccessІнформаційна технологія обробки даних електрокардіограм для знаходження R-піків
Запропоновано підхід до коректного обчислення похідної сигналу електрокардіограми (ЕКГ) для ефективного визначення R-піків на основі порогових алгоритмів. На відміну від існуючих порогових підходів з використанням обчислення похідної сигналу ЕКГ, даний підхід має істотні удосконалення в напрямку оптимізації обчислень, що дозволяє використовувати його для великих наборів даних. Новизна підходу полягає в тому, що для даних ЕКГ будується кусково-поліноміальне наближення, яке водночас є згладжуючим. Надалі обчислюється похідна від згладженої функції. Ефективність методу підтверджена за допомогою розробленої інформаційної технології для обчислення R-піків ЕКГ з відкритої бази MIT-BIH.
- Open Access
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Journal of Numerical and Applied Mathematics
- No. 1,p. 30-39
ALGORITHMIC AND GRAPHICAL TOOLS FOR PRE-PROCESSING OF HOLTER DATA
The work is dedicated to exploring methods of detecting cardiovascular diseases using Holter ECG analysis. An overview of the interface and capabilities of the program is conducted, and an analysis of the threshold algorithm for detecting potentially suspicious intervals is performed.
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Journal of Numerical and Applied Mathematics
- No. 1,p. 30-39
Open AccessALGORITHMIC AND GRAPHICAL TOOLS FOR PRE-PROCESSING OF HOLTER DATA
The work is dedicated to exploring methods of detecting cardiovascular diseases using Holter ECG analysis. An overview of the interface and capabilities of the program is conducted, and an analysis of the threshold algorithm for detecting potentially suspicious intervals is performed.