Misriana Misriana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Misriana Misriana has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Kartika Kartika
Universitas Malikussaleh
3 shared publications - Arnawan Hasibuan
Malikussaleh University
1 shared publication - Asran Asran
Universitas Malikussaleh
1 shared publication - Asran Asran
Universitas Malikussaleh
1 shared publication - Dewiyana
Universitas Samudra
1 shared publication Fitra Permana Putra
Universitas Malikussaleh
1 shared publication
Latest Publications
- Open Access
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 381-392
SCADA system in water storage tanks with NI vision LabVIEW
Advances in technology have driven the need for efficient water management systems. This study presents a SCADA-based water management system that integrates LabVIEW and Arduino to monitor and regulate water levels and flow rates in a storage tank. The system uses an HC-SRF04 ultrasonic sensor for water level measurement with 99.77% accuracy and an HX710 pressure sensor, which achieves 98.54% accuracy. The LabVIEW interface displays real-time data, giving users an intuitive view of system performance. A proportional integral derivative (PID) algorithm optimizes the water pump through pulse width modulation (PWM), achieving water flow rate control. The Ziegler-Nichols method tunes the PID parameters to Kp = 16.59, Ti = 1.102, and Td = 0.2755. This tuning ensures the system maintains a consistent target flow rate of 4 liters per minute (L/min) with minimal variation. Initial testing showed a 2.5% overshoot but stabilized at the desired flow rate within 10 seconds, indicating effective control. This SCADA system reduces water and energy waste by enabling continuous real-time monitoring and control. The system provides accurate data through a LabVIEW interface, ensuring effective and informed operational decisions. This robust solution supports efficient water management for industrial and environmental applications, contributing to sustainability and resource optimization.
- 1 September 2025
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Robotics and Automation (IJRA)
- Vol. 14 (3) , 381-392
Open AccessSCADA system in water storage tanks with NI vision LabVIEW
Advances in technology have driven the need for efficient water management systems. This study presents a SCADA-based water management system that integrates LabVIEW and Arduino to monitor and regulate water levels and flow rates in a storage tank. The system uses an HC-SRF04 ultrasonic sensor for water level measurement with 99.77% accuracy and an HX710 pressure sensor, which achieves 98.54% accuracy. The LabVIEW interface displays real-time data, giving users an intuitive view of system performance. A proportional integral derivative (PID) algorithm optimizes the water pump through pulse width modulation (PWM), achieving water flow rate control. The Ziegler-Nichols method tunes the PID parameters to Kp = 16.59, Ti = 1.102, and Td = 0.2755. This tuning ensures the system maintains a consistent target flow rate of 4 liters per minute (L/min) with minimal variation. Initial testing showed a 2.5% overshoot but stabilized at the desired flow rate within 10 seconds, indicating effective control. This SCADA system reduces water and energy waste by enabling continuous real-time monitoring and control. The system provides accurate data through a LabVIEW interface, ensuring effective and informed operational decisions. This robust solution supports efficient water management for industrial and environmental applications, contributing to sustainability and resource optimization.
- Open Access
- 1 March 2025
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 22 (1) , 53-62
Pengendalian Ketinggian Air pada Tangki Penampungan menggunakan Sensor Ultrasonik HC-SRF04
Sistem kendali ketinggian air pada tangki penampungan air sangat penting pada proses dalam dunia industri dalam menggunakan air. Penelitian ini bertujuan untuk merancang dan mengimplementasikan sistem kendali ketinggian air pada tangki penampungan air menggunakan sensor ultrasonik HC-SRF04. Sistem ini dirancang untuk mengukur ketinggian air secara otomatis dan mengontrol pompa serta selenoid valve berdasarkan data yang diterima dari sensor. Hasil pengujian menunjukkan bahwa sistem bekerja dengan tingkat akurasi yang baik, dengan rata-rata kesalahan pengukuran (error) yang rendah, berkisar antara 0,23% hingga 0,96% pada berbagai ketinggian air mulai dari 5 cm hingga 30 cm. Persentase kesalahan terbesar ditemukan pada jarak 5 cm sebesar 1,8%, sementara kesalahan semakin menurun untuk jarak yang lebih besar, mencapai 0,23% pada pengukuran jarak 30 cm. Penggunaan modul driver L298N dan kalibrasi sensor berkontribusi dalam meningkatkan akurasi sistem. Secara keseluruhan, sistem ini terbukti handal dalam menjaga ketinggian air yang stabil pada tangki, dan dapat diaplikasikan secara efisien dalam otomasi industri.
- 1 March 2025
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 22 (1) , 53-62
Open AccessPengendalian Ketinggian Air pada Tangki Penampungan menggunakan Sensor Ultrasonik HC-SRF04
Sistem kendali ketinggian air pada tangki penampungan air sangat penting pada proses dalam dunia industri dalam menggunakan air. Penelitian ini bertujuan untuk merancang dan mengimplementasikan sistem kendali ketinggian air pada tangki penampungan air menggunakan sensor ultrasonik HC-SRF04. Sistem ini dirancang untuk mengukur ketinggian air secara otomatis dan mengontrol pompa serta selenoid valve berdasarkan data yang diterima dari sensor. Hasil pengujian menunjukkan bahwa sistem bekerja dengan tingkat akurasi yang baik, dengan rata-rata kesalahan pengukuran (error) yang rendah, berkisar antara 0,23% hingga 0,96% pada berbagai ketinggian air mulai dari 5 cm hingga 30 cm. Persentase kesalahan terbesar ditemukan pada jarak 5 cm sebesar 1,8%, sementara kesalahan semakin menurun untuk jarak yang lebih besar, mencapai 0,23% pada pengukuran jarak 30 cm. Penggunaan modul driver L298N dan kalibrasi sensor berkontribusi dalam meningkatkan akurasi sistem. Secara keseluruhan, sistem ini terbukti handal dalam menjaga ketinggian air yang stabil pada tangki, dan dapat diaplikasikan secara efisien dalam otomasi industri.
- Open Access
- 1 September 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 21 (2) , 69-73
Analisis Kinerja Jaringan Radio over Fiber (RoF) menggunakan Optical Amplifier
Perkembangan teknologi telekomunikasi menuntut peningkatan kecepatan dan keandalan pertukaran data. Meskipun sistem transmisi kabel memiliki kecepatan tinggi dan performa prima, namun biaya instalasi yang dibutuhkan cukup besar. Sebagai solusi, Radio over Fiber (RoF) dihadirkan untuk mengintegrasikan jaringan nirkabel dan kabel. Pilihan penguat optik, seperti Erbium Doped Fiber Amplifier (EDFA), dan modulator RF QAM yang tepat dapat meningkatkan kinerja transmisi Radio over Fiber. Penelitian ini bertujuan merancang dan membuat sistem RoF yang disimulasikan menggunakan software Optisystem. Sistem menggunakan modulasi 4-QAM, yang dijalankan dengan menggunakan EDFA dan tanpa EDFA. Parameter yang dianalisis adalah Q-factor, OSNR, dan BER. Hasil penelitian menunjukkan bahwa sistem dengan menggunakan EDFA, pada jarak 85 km diperoleh nilai Q-factor sebesar 6,1427, OSNR 23,20993, dan nilai BER 4,05625 ´ 10−10. Sedangkan pada skema pengujian jarak 90 km s/d jarak 200 km, kondisi transmisi tidak memenuhi standar kelayakan yang ditetapkan. Hal ini disebabkan oleh panjang link yang dilewati semakin jauh dan menimbulkan dispersi loss yang semakin besar.
- 1 September 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 21 (2) , 69-73
Open AccessAnalisis Kinerja Jaringan Radio over Fiber (RoF) menggunakan Optical Amplifier
Perkembangan teknologi telekomunikasi menuntut peningkatan kecepatan dan keandalan pertukaran data. Meskipun sistem transmisi kabel memiliki kecepatan tinggi dan performa prima, namun biaya instalasi yang dibutuhkan cukup besar. Sebagai solusi, Radio over Fiber (RoF) dihadirkan untuk mengintegrasikan jaringan nirkabel dan kabel. Pilihan penguat optik, seperti Erbium Doped Fiber Amplifier (EDFA), dan modulator RF QAM yang tepat dapat meningkatkan kinerja transmisi Radio over Fiber. Penelitian ini bertujuan merancang dan membuat sistem RoF yang disimulasikan menggunakan software Optisystem. Sistem menggunakan modulasi 4-QAM, yang dijalankan dengan menggunakan EDFA dan tanpa EDFA. Parameter yang dianalisis adalah Q-factor, OSNR, dan BER. Hasil penelitian menunjukkan bahwa sistem dengan menggunakan EDFA, pada jarak 85 km diperoleh nilai Q-factor sebesar 6,1427, OSNR 23,20993, dan nilai BER 4,05625 ´ 10−10. Sedangkan pada skema pengujian jarak 90 km s/d jarak 200 km, kondisi transmisi tidak memenuhi standar kelayakan yang ditetapkan. Hal ini disebabkan oleh panjang link yang dilewati semakin jauh dan menimbulkan dispersi loss yang semakin besar.
- Open Access
- 31 July 2024
- Published by Politeknik Negeri Malang in Jurnal Elektronika dan Otomasi Industri
- Vol. 11 (2) , 503-511
Implementation of Linear Regression Method for Calibration and Temperature Measurement on PT100 Temperature Sensor
The PT100 temperature sensor, a type RTD (resistance temperature detector), is widely employed in industries, particularly for steam boiler temperature regulation. Precise temperature measurement is vital for operational efficiency and safety maintenance. Utilizing linear regression for calibrating and measuring temperature with the PT100 sensor integrated with Arduino Uno and LCD I2C is proposed to enhance accuracy. Testing involved assembling the PT100 sensor with Arduino Uno and LCD I2C. Test data were employed for linear regression to derive the calibration equation. Measurements were conducted by comparing PT100 sensor readings with a digital thermometer across a temperature range of 30ºC to 75ºC at 5ºC intervals, with each temperature point tested five times. Results exhibit good accuracy in temperature measurement with the PT100 sensor, featuring low error and percentage error. The standard deviation indicates consistent measurement. Integration of the PT100 temperature sensor with Arduino Uno and LCD I2C, coupled with linear regression for calibration, yields a precise temperature measurement system. Testing against a digital thermometer demonstrates highly accurate outcomes. This developed system finds application in high-precision temperature measurement for steam boiler operations.
- 31 July 2024
- Published by Politeknik Negeri Malang in Jurnal Elektronika dan Otomasi Industri
- Vol. 11 (2) , 503-511
Open AccessImplementation of Linear Regression Method for Calibration and Temperature Measurement on PT100 Temperature Sensor
The PT100 temperature sensor, a type RTD (resistance temperature detector), is widely employed in industries, particularly for steam boiler temperature regulation. Precise temperature measurement is vital for operational efficiency and safety maintenance. Utilizing linear regression for calibrating and measuring temperature with the PT100 sensor integrated with Arduino Uno and LCD I2C is proposed to enhance accuracy. Testing involved assembling the PT100 sensor with Arduino Uno and LCD I2C. Test data were employed for linear regression to derive the calibration equation. Measurements were conducted by comparing PT100 sensor readings with a digital thermometer across a temperature range of 30ºC to 75ºC at 5ºC intervals, with each temperature point tested five times. Results exhibit good accuracy in temperature measurement with the PT100 sensor, featuring low error and percentage error. The standard deviation indicates consistent measurement. Integration of the PT100 temperature sensor with Arduino Uno and LCD I2C, coupled with linear regression for calibration, yields a precise temperature measurement system. Testing against a digital thermometer demonstrates highly accurate outcomes. This developed system finds application in high-precision temperature measurement for steam boiler operations.
- Open Access
- 6 May 2024
- Published by LPPM Universitas Malikussaleh in Journal of Renewable Energy, Electrical, and Computer Engineering
- Vol. 4 (1) , 23-31
Matlab Simulation Using Kalman Filter Algorithm to Reduce Noise in Voice Signals
Sound signals polluted by noise are a common problem in various audio applications, including communication, sound processing, and audio recording. In this article, proposes the use of Kalman Filter algorithm as an effective method to reduce noise in speech signals. Simulations are performed using Matlab software to implement the Kalman Filter algorithm on noise polluted voice signals. The study includes several important steps, including the input of noise-polluted speech signals and the implementation of the Kalman Filter to clean the signals. Simulation results are measured using commonly used audio quality metrics, such as Signal-to-Noise Ratio (SNR) and Mean Square Error (MSE), to evaluate the effectiveness of the algorithm. The results from the simulations show that the use of the Kalman Filter algorithm significantly improves the quality of noise-contaminated speech signals. These results indicate that this algorithm can be a potential solution to the problem of noise reduction in audio applications. In addition, the implementation in the Matlab environment allows for easy testing and adaptation of this algorithm for different types of audio applications. This research makes a positive contribution to the development of more efficient noise reduction techniques in speech signal processing, focusing on the use of the Kalman Filter algorithm and its implementation using Matlab software. The implications of this research can be potentially beneficial in improving the quality of sound signals in various audio application contexts.
- 6 May 2024
- Published by LPPM Universitas Malikussaleh in Journal of Renewable Energy, Electrical, and Computer Engineering
- Vol. 4 (1) , 23-31
Open AccessMatlab Simulation Using Kalman Filter Algorithm to Reduce Noise in Voice Signals
Sound signals polluted by noise are a common problem in various audio applications, including communication, sound processing, and audio recording. In this article, proposes the use of Kalman Filter algorithm as an effective method to reduce noise in speech signals. Simulations are performed using Matlab software to implement the Kalman Filter algorithm on noise polluted voice signals. The study includes several important steps, including the input of noise-polluted speech signals and the implementation of the Kalman Filter to clean the signals. Simulation results are measured using commonly used audio quality metrics, such as Signal-to-Noise Ratio (SNR) and Mean Square Error (MSE), to evaluate the effectiveness of the algorithm. The results from the simulations show that the use of the Kalman Filter algorithm significantly improves the quality of noise-contaminated speech signals. These results indicate that this algorithm can be a potential solution to the problem of noise reduction in audio applications. In addition, the implementation in the Matlab environment allows for easy testing and adaptation of this algorithm for different types of audio applications. This research makes a positive contribution to the development of more efficient noise reduction techniques in speech signal processing, focusing on the use of the Kalman Filter algorithm and its implementation using Matlab software. The implications of this research can be potentially beneficial in improving the quality of sound signals in various audio application contexts.
- Open Access
- 1 March 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 21 (1) , 55-58
Analisis Quality of Service pada Jaringan 5G dengan menggunakan Software Wireshark di Kota Medan
Perkembangan teknologi telekomunikasi berlangsung dengan cepat. Salah satu perkembangan tersebut adalah teknologi seluler generasi kelima atau 5G. Jaringan ini merupakan pengembangan dari jaringan 4G/LTE. Jaringan 5G memberikan kualitas layanan yang lebih baik untuk pengguna dibandingkan dengan jaringan 4G/LTE. Pada penelitian ini dilakukan pengujian Quality of Service (QoS) pada jaringan 5G untuk layanan internet. Pengujian QoS dilakukan di Kota Medan pada 20 juli 2023 sampai dengan 21 juli 2023, dengan lokasi Jl. Pengeran Diponegoro Medan, dan Jl. Putri Hijau Medan. Provider internet yang diuji adalah XL dan Telkomsel. Pengujian QoS dengan menggunakan Software Wireshark, dan parameter yang diuji adalah throughput, delay, dan packet loss. Hasil pengukuran QoS dari kedua jaringan diperoleh nilai throughput rata-rata 1.319 kbps untuk provider XL dan 1.453,25 kbps untuk provider Telkomsel, delay rata-rata 6,82 ms untuk provider XL dan 6,15 ms untuk provider Telkomsel, serta packet loss rata-rata 1,575% untuk provider XL dan 1,65% untuk provider Telkomsel.
- 1 March 2024
- Published by Politeknik Negeri Lhokseumawe in Jurnal Litek : Jurnal Listrik Telekomunikasi Elektronika
- Vol. 21 (1) , 55-58
Open AccessAnalisis Quality of Service pada Jaringan 5G dengan menggunakan Software Wireshark di Kota Medan
Perkembangan teknologi telekomunikasi berlangsung dengan cepat. Salah satu perkembangan tersebut adalah teknologi seluler generasi kelima atau 5G. Jaringan ini merupakan pengembangan dari jaringan 4G/LTE. Jaringan 5G memberikan kualitas layanan yang lebih baik untuk pengguna dibandingkan dengan jaringan 4G/LTE. Pada penelitian ini dilakukan pengujian Quality of Service (QoS) pada jaringan 5G untuk layanan internet. Pengujian QoS dilakukan di Kota Medan pada 20 juli 2023 sampai dengan 21 juli 2023, dengan lokasi Jl. Pengeran Diponegoro Medan, dan Jl. Putri Hijau Medan. Provider internet yang diuji adalah XL dan Telkomsel. Pengujian QoS dengan menggunakan Software Wireshark, dan parameter yang diuji adalah throughput, delay, dan packet loss. Hasil pengukuran QoS dari kedua jaringan diperoleh nilai throughput rata-rata 1.319 kbps untuk provider XL dan 1.453,25 kbps untuk provider Telkomsel, delay rata-rata 6,82 ms untuk provider XL dan 6,15 ms untuk provider Telkomsel, serta packet loss rata-rata 1,575% untuk provider XL dan 1,65% untuk provider Telkomsel.