Yongha Chang
Research Subjects
Research Interests
Yongha Chang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hwangeui Cho
Institute of New Drug Development, School of Pharmacy, Jeonbuk National University, Jeonju 54896, Republic of Korea
1 shared publication - Joon-Sang Park
Corporation VIVAGEN, Seongnam 13219, Republic of Korea
1 shared publication - Jung Bok Kim
Department of Yuhan Biotechnology, School of Bio-Health Sciences, Yuhan University, Bucheon 14780, Republic of Korea
1 shared publication - Sang-Hyun Ahn
Corporation VIVAGEN, Seongnam 13219, Republic of Korea
1 shared publication - Soonho Kwon
Corporation VIVAGEN, Seongnam 13219, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 May 2025
- Published by MDPI AG in Separations
- Vol. 12 (5) , 122
Development and Validation of a Sensitive LC-MS/MS Method for the Determination of N-Nitroso-Atenolol in Atenolol-Based Pharmaceuticals
The recent detection of N-nitroso-atenolol, a mutagenic and potentially carcinogenic impurity in atenolol-based pharmaceuticals, has raised serious safety concerns and emphasized the need for stringent analytical control. This study developed and validated a highly sensitive LC-MS/MS method for quantifying N-nitroso-atenolol in both active pharmaceutical ingredients (APIs) and finished products. Quantification was carried out using multiple reaction monitoring (MRM) under positive-mode electrospray ionization (ESI). Separation was performed on a C18 reversed-phase column with a gradient of water and methanol containing 0.1% formic acid. The method was validated to meet a specification limit of 15 ng/mg, with a linear range of 0.5–80 ng/mL, effectively covering 10–400% of the regulatory threshold. The method exhibited an excellent performance in terms of specificity, accuracy, precision, linearity, and robustness. It achieved a limit of detection (LOD) of 0.2 ng/mL (0.30 ng/mg) and a limit of quantification (LOQ) of 0.5 ng/mL (0.75 ng/mg), alongside a comprehensive uncertainty analysis with an expanded uncertainty of ±3.86 mg/kg. Application to commercial atenolol products confirmed the reliability and practical utility of the method. This validated approach offers a critical tool for pharmaceutical manufacturers and regulatory agencies to monitor and control N-nitroso-atenolol, ensuring compliance and enhancing patient safety.
- 12 May 2025
- Published by MDPI AG in Separations
- Vol. 12 (5) , 122
Open AccessDevelopment and Validation of a Sensitive LC-MS/MS Method for the Determination of N-Nitroso-Atenolol in Atenolol-Based Pharmaceuticals
The recent detection of N-nitroso-atenolol, a mutagenic and potentially carcinogenic impurity in atenolol-based pharmaceuticals, has raised serious safety concerns and emphasized the need for stringent analytical control. This study developed and validated a highly sensitive LC-MS/MS method for quantifying N-nitroso-atenolol in both active pharmaceutical ingredients (APIs) and finished products. Quantification was carried out using multiple reaction monitoring (MRM) under positive-mode electrospray ionization (ESI). Separation was performed on a C18 reversed-phase column with a gradient of water and methanol containing 0.1% formic acid. The method was validated to meet a specification limit of 15 ng/mg, with a linear range of 0.5–80 ng/mL, effectively covering 10–400% of the regulatory threshold. The method exhibited an excellent performance in terms of specificity, accuracy, precision, linearity, and robustness. It achieved a limit of detection (LOD) of 0.2 ng/mL (0.30 ng/mg) and a limit of quantification (LOQ) of 0.5 ng/mL (0.75 ng/mg), alongside a comprehensive uncertainty analysis with an expanded uncertainty of ±3.86 mg/kg. Application to commercial atenolol products confirmed the reliability and practical utility of the method. This validated approach offers a critical tool for pharmaceutical manufacturers and regulatory agencies to monitor and control N-nitroso-atenolol, ensuring compliance and enhancing patient safety.