L. Thinova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
L. Thinova has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
I. Burian
National Radiation, Chemical and Biological Protection Institute , Radon Experts Group, Kamenná, 262 31 Milín, Pribram , Czech Republic
1 shared publication
Latest Publications
- 2 April 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 130 (1) , 48-51
Effective dose assessment for workers in caves in the Czech Republic: experiments with passive radon detectors
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN system consists of a plastic chamber that is conically cylindrical in shape and about 0.5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited decay products of radon. Kodak has a spectrometric character—the tracks are visualized only for alphas with energies between 1 and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy.
- 2 April 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 130 (1) , 48-51
Effective dose assessment for workers in caves in the Czech Republic: experiments with passive radon detectors
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN system consists of a plastic chamber that is conically cylindrical in shape and about 0.5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited decay products of radon. Kodak has a spectrometric character—the tracks are visualized only for alphas with energies between 1 and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy.