Anttoni Korkiakoski
Research Subjects
Research Interests
Anttoni Korkiakoski has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Anna Musku
Genomill Health Inc., Turku, 20520, Finland
3 shared publications- Jorma Kim
Natural Chemistry Research Group, Department of Chemistry, University of Turku, FI-20014, Turku, Finland
3 shared publications - Juha-Pekka Pursiheimo
Genomill Health Inc., Turku, 20520, Finland
3 shared publications - Jukka Laine
Department of Pathology and Institute of Biomedicine, Turku University Hospital and University of Turku, Finland
3 shared publications - Manu Tamminen
Department of Biology, University of Turku, Turku, Finland
3 shared publications - Nea Laine
Genomill Health Inc., Turku, 20520, Finland
3 shared publications
Latest Publications
- Open Access
Application of the Nicking Loop™ targeted library preparation method to DNBSEQ™ sequencing
Nicking Loop™ is a PCR-free targeted library preparation method that combines conversion of linear target DNA into circular single-stranded DNA (CssDNA) library with early sample indexing in a single step. The resulting CssDNA libraries can be either directly sequenced or optionally amplified, offering maximum flexibility across sequencing applications. This study demonstrates the compatibility of Nicking Loop™ circular libraries with a MGI’s DNBSEQ™ platform. Compatibility was evaluated against established linear Nicking Loop™ libraries sequenced on Illumina MiSeq platform. Using synthetic reference samples with defined variant allele frequencies, Nicking Loop™ method demonstrated matching performance across both library formats and sequencing platforms. Key quality metrics, including unique molecular identifier (UMI) distributions, error profiles and VAF detection, were all highly consistent. Both library types generated over 97% singleton UMIs, indicating uniform template sampling, and VAF measurements were strongly concordant across platforms (Spearman’s ρ = 0.939). Collectively, these findings demonstrate that Nicking Loop™ method is directly applicable to circular NGS platforms, such as DNBSEQ™, strongly supporting its use as a platform-agnostic library preparation strategy for targeted sequencing applications.
Open AccessApplication of the Nicking Loop™ targeted library preparation method to DNBSEQ™ sequencing
Nicking Loop™ is a PCR-free targeted library preparation method that combines conversion of linear target DNA into circular single-stranded DNA (CssDNA) library with early sample indexing in a single step. The resulting CssDNA libraries can be either directly sequenced or optionally amplified, offering maximum flexibility across sequencing applications. This study demonstrates the compatibility of Nicking Loop™ circular libraries with a MGI’s DNBSEQ™ platform. Compatibility was evaluated against established linear Nicking Loop™ libraries sequenced on Illumina MiSeq platform. Using synthetic reference samples with defined variant allele frequencies, Nicking Loop™ method demonstrated matching performance across both library formats and sequencing platforms. Key quality metrics, including unique molecular identifier (UMI) distributions, error profiles and VAF detection, were all highly consistent. Both library types generated over 97% singleton UMIs, indicating uniform template sampling, and VAF measurements were strongly concordant across platforms (Spearman’s ρ = 0.939). Collectively, these findings demonstrate that Nicking Loop™ method is directly applicable to circular NGS platforms, such as DNBSEQ™, strongly supporting its use as a platform-agnostic library preparation strategy for targeted sequencing applications.
- Open Access
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Evaluation of Bridge Capture technology for mutation profiling in liquid biopsies of metastatic colorectal cancer patients
Colorectal cancer (CRC) is the second leading cause of cancer-related deaths, often presenting at an advanced stage with significant molecular heterogeneity. This is the first study to evaluate the performance of a novel next-generation sequencing (NGS)-based Bridge Capture technology for mutation profiling and minimal residual disease detection in circulating tumor (ct)DNA from metastatic colorectal cancer (mCRC) patients. Its performance was compared to those of droplet digital PCR (ddPCR), Ion AmpliSeq Cancer Hotspot Panel v2, and Idylla ctKRAS Mutation Assay. Eighty serial plasma samples from ten mCRC patients were analyzed by Bridge Capture and ddPCR, demonstrating a very strong correlation in variant allele frequency (VAF) values (rs = 0.86). The concordance of Bridge Capture with ddPCR (kappa = 0.70) and Idylla (kappa = 0.79) showed substantial agreement. A subset of samples (n = 10) was analyzed using the Ion AmpliSeq NGS-panel and both methods identified 15 driver mutations with strong correlation of VAF values (rs = 0.74). Additionally, Bridge Capture identified several oncogenic mutations beyond those detected by Ion AmpliSeq, highlighting its comprehensive profiling capability. The scalability of Bridge Capture was validated using an expanded panel and synthetic DNA targets, showing a strong linear correlation between observed and expected VAF values. This study demonstrates the scalability and accuracy of the Bridge Capture platform, and its potential to enhance mutation detection and clinical decision-making using ctDNA samples from patients with mCRC.
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessEvaluation of Bridge Capture technology for mutation profiling in liquid biopsies of metastatic colorectal cancer patients
Colorectal cancer (CRC) is the second leading cause of cancer-related deaths, often presenting at an advanced stage with significant molecular heterogeneity. This is the first study to evaluate the performance of a novel next-generation sequencing (NGS)-based Bridge Capture technology for mutation profiling and minimal residual disease detection in circulating tumor (ct)DNA from metastatic colorectal cancer (mCRC) patients. Its performance was compared to those of droplet digital PCR (ddPCR), Ion AmpliSeq Cancer Hotspot Panel v2, and Idylla ctKRAS Mutation Assay. Eighty serial plasma samples from ten mCRC patients were analyzed by Bridge Capture and ddPCR, demonstrating a very strong correlation in variant allele frequency (VAF) values (rs = 0.86). The concordance of Bridge Capture with ddPCR (kappa = 0.70) and Idylla (kappa = 0.79) showed substantial agreement. A subset of samples (n = 10) was analyzed using the Ion AmpliSeq NGS-panel and both methods identified 15 driver mutations with strong correlation of VAF values (rs = 0.74). Additionally, Bridge Capture identified several oncogenic mutations beyond those detected by Ion AmpliSeq, highlighting its comprehensive profiling capability. The scalability of Bridge Capture was validated using an expanded panel and synthetic DNA targets, showing a strong linear correlation between observed and expected VAF values. This study demonstrates the scalability and accuracy of the Bridge Capture platform, and its potential to enhance mutation detection and clinical decision-making using ctDNA samples from patients with mCRC.
- Open Access
Nicking Loop™: An infinite amplification of single-stranded circular DNA
Circular single-stranded DNA (CssDNA) offers unique advantages for molecular diagnostics and next-generation sequencing (NGS) due to its nuclease resistance and compatibility with rolling circle amplification. We present the Nicking Loop™, a novel and versatile method for converting both single- and double-stranded DNA into CssDNA and enabling robust, unbiased amplification. This technique preserves the original DNA template composition and outperforms PCR in reproducibility and sensitivity, particularly for low variant allele frequencies. We demonstrate that Nicking Loop-amplified CssDNA is directly compatible with NGS platforms utilizing circular DNA as a sequencing template and introduce a novel loop-based indexing strategy that enables efficient sample multiplexing. Furthermore, we confirm the method's compatibility with Nanopore sequencing technologies, highlighting its broad applicability across sequencing platforms. Our results establish Nicking Loop™ as an alternative to conventional linear library preparation, streamlining workflows while enhancing sequencing accuracy and efficiency. Beyond its immediate application in NGS, the method holds promise for broader use in molecular biology, e.g. in DNA data storage. This proof-of-concept study highlights the transformative potential of Nicking Loop™ in enabling a shift toward circular DNA libraries for new generation of assay preps and precision sequencing applications.
Open AccessNicking Loop™: An infinite amplification of single-stranded circular DNA
Circular single-stranded DNA (CssDNA) offers unique advantages for molecular diagnostics and next-generation sequencing (NGS) due to its nuclease resistance and compatibility with rolling circle amplification. We present the Nicking Loop™, a novel and versatile method for converting both single- and double-stranded DNA into CssDNA and enabling robust, unbiased amplification. This technique preserves the original DNA template composition and outperforms PCR in reproducibility and sensitivity, particularly for low variant allele frequencies. We demonstrate that Nicking Loop-amplified CssDNA is directly compatible with NGS platforms utilizing circular DNA as a sequencing template and introduce a novel loop-based indexing strategy that enables efficient sample multiplexing. Furthermore, we confirm the method's compatibility with Nanopore sequencing technologies, highlighting its broad applicability across sequencing platforms. Our results establish Nicking Loop™ as an alternative to conventional linear library preparation, streamlining workflows while enhancing sequencing accuracy and efficiency. Beyond its immediate application in NGS, the method holds promise for broader use in molecular biology, e.g. in DNA data storage. This proof-of-concept study highlights the transformative potential of Nicking Loop™ in enabling a shift toward circular DNA libraries for new generation of assay preps and precision sequencing applications.