Axel Günther
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Axel Günther has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Eugenia Kumacheva
Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
5 shared publications - Milad Abolhasani
North Carolina State University
5 shared publications Ali Oskooei
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada.
3 shared publicationsArianna McAllister
Institute of Biomedical Engineering University of Toronto 164 College Street Toronto Ontario M5S 3G9 Canada
3 shared publicationsLian Leng
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
3 shared publicationsSanjesh Yasotharan
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S3G8, Canada.
3 shared publications
Latest Publications
- Open Access
Conformal Bioprinting of Bi-phasic Jammed Bioinks, Independent of Gravity, Orientation, and Curvature
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remain a key challenge for clinical translation. Here, we present a gravity-independent, conformal bioprinting strategy using bi-phasic granular bioink and multinozzle printheads capable of adapting to arbitrary surface curvatures. The bioink comprised of jammed gelatin microgels suspended in a fibrinogen matrix exhibits yield-stress behavior to maintain shape fidelity after extrusion while supporting cell viability and proliferation. Two monolithic multinozzle printhead architectures with identical bioink delivery networks were evaluated: (1) a rigid configuration for handheld bioprinting and (2) a soft robotic variant capable of real-time curvature adaptation via pneumatic actuation. Microgravity experiments aboard a parabolic flight confirmed successful bioink deposition under ∼0 g conditions. A ladder-rung microfluidic architecture ensured uniform bioink delivery across printhead nozzles, improving deposition consistency. In situ bioprinting on anatomical facial phantoms confirmed conformal, high-throughput (deposition at 20 mm·s -1 ) deposition of bioink over physiologically relevant curvatures, both with and without cells. Cell-laden constructs retained >85% cell viability post-printing and supported proliferation. This work introduces a scalable bioprinting platform suitable for clinical, remote, and deep-space environments, enabling autonomous tissue fabrication. The curvature-adaptive printhead advances current in situ bioprinting capabilities, facilitating the generation of personalized grafts with complex anatomical geometries.
Open AccessConformal Bioprinting of Bi-phasic Jammed Bioinks, Independent of Gravity, Orientation, and Curvature
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remain a key challenge for clinical translation. Here, we present a gravity-independent, conformal bioprinting strategy using bi-phasic granular bioink and multinozzle printheads capable of adapting to arbitrary surface curvatures. The bioink comprised of jammed gelatin microgels suspended in a fibrinogen matrix exhibits yield-stress behavior to maintain shape fidelity after extrusion while supporting cell viability and proliferation. Two monolithic multinozzle printhead architectures with identical bioink delivery networks were evaluated: (1) a rigid configuration for handheld bioprinting and (2) a soft robotic variant capable of real-time curvature adaptation via pneumatic actuation. Microgravity experiments aboard a parabolic flight confirmed successful bioink deposition under ∼0 g conditions. A ladder-rung microfluidic architecture ensured uniform bioink delivery across printhead nozzles, improving deposition consistency. In situ bioprinting on anatomical facial phantoms confirmed conformal, high-throughput (deposition at 20 mm·s -1 ) deposition of bioink over physiologically relevant curvatures, both with and without cells. Cell-laden constructs retained >85% cell viability post-printing and supported proliferation. This work introduces a scalable bioprinting platform suitable for clinical, remote, and deep-space environments, enabling autonomous tissue fabrication. The curvature-adaptive printhead advances current in situ bioprinting capabilities, facilitating the generation of personalized grafts with complex anatomical geometries.
- Open Access
- 1 May 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (14)
Microfluidic Production of Ultrathin, Handleable Collagen Sheets Exhibiting Toe‐heel Tensile Behavior
The extracellular matrix (ECM) of cardiovascular tissues displays a non‐linear, strain‐dependent elastic modulus, attributed to the hierarchical organization of collagen. At low loads, these tissues exhibit compliance, permit contraction or dilation, while at high loads, they stiffen and increase their mechanical strength at least tenfold. Although collagen gels are widely used in 3D cell culture, tissue engineering, and biofabrication, current engineering techniques fail to replicate this hierarchical organization at the microscale. As a result, they often lack either the non‐linear tensile behavior or the physiologically relevant strength of native tissues. To address this limitation, we present ultrathin, templated collagen sheets (1.8 microns thin and 10 mm wide) from an acidic collagen solution using a microfluidic wet spinning process, incorporating and later removing microscale oil droplets at 2.3% volume concentration. Templated collagen sheets exhibit a two‐fold increase in fibril alignment dispersion compared with non‐templated ones. When assessed along their length, the Young's modulus of the templated sheets increases 62‐fold at 90% failure strain, recapitulating the tensile behavior of native load‐bearing tissues. We anticipate that these ultrathin templated collagen sheets will serve as substrate materials for the bottom‐up fabrication of load‐bearing biomaterials and tissue structures for in vitro applications and implantation.
- 1 May 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (14)
Open AccessMicrofluidic Production of Ultrathin, Handleable Collagen Sheets Exhibiting Toe‐heel Tensile Behavior
The extracellular matrix (ECM) of cardiovascular tissues displays a non‐linear, strain‐dependent elastic modulus, attributed to the hierarchical organization of collagen. At low loads, these tissues exhibit compliance, permit contraction or dilation, while at high loads, they stiffen and increase their mechanical strength at least tenfold. Although collagen gels are widely used in 3D cell culture, tissue engineering, and biofabrication, current engineering techniques fail to replicate this hierarchical organization at the microscale. As a result, they often lack either the non‐linear tensile behavior or the physiologically relevant strength of native tissues. To address this limitation, we present ultrathin, templated collagen sheets (1.8 microns thin and 10 mm wide) from an acidic collagen solution using a microfluidic wet spinning process, incorporating and later removing microscale oil droplets at 2.3% volume concentration. Templated collagen sheets exhibit a two‐fold increase in fibril alignment dispersion compared with non‐templated ones. When assessed along their length, the Young's modulus of the templated sheets increases 62‐fold at 90% failure strain, recapitulating the tensile behavior of native load‐bearing tissues. We anticipate that these ultrathin templated collagen sheets will serve as substrate materials for the bottom‐up fabrication of load‐bearing biomaterials and tissue structures for in vitro applications and implantation.
- Open Access
- 2 July 2024
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 9 (10) , 2584-2598
Scalable preparation of macroporous collagen microgels by air bubble-induced breakup and ice templating
Collagen I, the most abundant protein of the extracellular matrix, has found widespread use in three-dimensional cell culture, and increasingly also in bioprinting and biofabrication applications. However, several limitations remain, such as the capacity to locally recapitulate the multiscale organization of collagen in native tissues. Bioprinting cellular collagen structures with high feature fidelity so far either requires a more rapidly gelling biopolymer to be added or an acellular collagen structure to be defined before the delivery of cells. Here, we report the flow synthesis of macroporous collagen microgels (MCMs) that serve as building blocks for granular bioinks. Obtained bioinks offer excellent printability, provide an avenue to faithfully recapitulate the multiscale collagen organization of native tissues, and overcome the aforementioned limitations. Viscous collagen solutions with concentrations as high as 10 mg ml−1 are consistently converted into droplets using a parallelized microfluidic device via air bubble induced droplet breakup into a continuous oil phase. MCMs are obtained by inducing gelation, oil removal, and washing, and incorporating internal pores of tunable size via ice templating at freezing rates between 0.1 and 10 °C min−1. Independent control over the MCM diameter (175–250 μm) and porosity (58–76%) allows the extracellular matrix structure to be tailored to different tissue engineering applications. The wall structures within MCMs share similarities with the highly compacted and recapitulated collagen porosity in native tissues. This approach in the future can be used to 3D print more complicated biomimetic structures that require cell positioning during printing.
- 2 July 2024
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 9 (10) , 2584-2598
Open AccessScalable preparation of macroporous collagen microgels by air bubble-induced breakup and ice templating
Collagen I, the most abundant protein of the extracellular matrix, has found widespread use in three-dimensional cell culture, and increasingly also in bioprinting and biofabrication applications. However, several limitations remain, such as the capacity to locally recapitulate the multiscale organization of collagen in native tissues. Bioprinting cellular collagen structures with high feature fidelity so far either requires a more rapidly gelling biopolymer to be added or an acellular collagen structure to be defined before the delivery of cells. Here, we report the flow synthesis of macroporous collagen microgels (MCMs) that serve as building blocks for granular bioinks. Obtained bioinks offer excellent printability, provide an avenue to faithfully recapitulate the multiscale collagen organization of native tissues, and overcome the aforementioned limitations. Viscous collagen solutions with concentrations as high as 10 mg ml−1 are consistently converted into droplets using a parallelized microfluidic device via air bubble induced droplet breakup into a continuous oil phase. MCMs are obtained by inducing gelation, oil removal, and washing, and incorporating internal pores of tunable size via ice templating at freezing rates between 0.1 and 10 °C min−1. Independent control over the MCM diameter (175–250 μm) and porosity (58–76%) allows the extracellular matrix structure to be tailored to different tissue engineering applications. The wall structures within MCMs share similarities with the highly compacted and recapitulated collagen porosity in native tissues. This approach in the future can be used to 3D print more complicated biomimetic structures that require cell positioning during printing.
- 10 March 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (8) , 2001746
One‐Step Formation of Protein‐Based Tubular Structures for Functional Devices and Tissues
Tubular biological structures consisting of extracellular matrix (ECM) proteins and cells are basic functional units of all organs in animals and humans. ECM protein solutions at low concentrations (5–10 milligrams per milliliter) are abundantly used in 3D cell culture. However, their poor “printability” and minute‐long gelation time have made the direct extrusion of tubular structures in bioprinting applications challenging. Here, this limitation is overcome and the continuous, template‐free conversion of low‐concentration collagen, elastin, and fibrinogen solutions into tubular structures of tailored size and radial, circumferential and axial organization is demonstrated. The approach is enabled by a microfabricated printhead for the consistent circumferential distribution of ECM protein solutions and lends itself to scalable manufacture. The attached confinement accommodates minute‐long residence times for pH, temperature, light, ionic and enzymatic gelation. Chip hosted ECM tubular structures are amenable to perfusion with aqueous solutions and air, and cyclic stretching. Predictive collapse and reopening in a crossed‐tube configuration promote all‐ECM valves and pumps. Tissue level function is demonstrated by factors secreted from cells embedded within the tube wall, as well as endothelial or epithelial barriers lining the lumen. The described approaches are anticipated to find applications in ECM‐based organ‐on‐chip and biohybrid structures, hydraulic actuators, and soft machines.
- 10 March 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (8) , 2001746
One‐Step Formation of Protein‐Based Tubular Structures for Functional Devices and Tissues
Tubular biological structures consisting of extracellular matrix (ECM) proteins and cells are basic functional units of all organs in animals and humans. ECM protein solutions at low concentrations (5–10 milligrams per milliliter) are abundantly used in 3D cell culture. However, their poor “printability” and minute‐long gelation time have made the direct extrusion of tubular structures in bioprinting applications challenging. Here, this limitation is overcome and the continuous, template‐free conversion of low‐concentration collagen, elastin, and fibrinogen solutions into tubular structures of tailored size and radial, circumferential and axial organization is demonstrated. The approach is enabled by a microfabricated printhead for the consistent circumferential distribution of ECM protein solutions and lends itself to scalable manufacture. The attached confinement accommodates minute‐long residence times for pH, temperature, light, ionic and enzymatic gelation. Chip hosted ECM tubular structures are amenable to perfusion with aqueous solutions and air, and cyclic stretching. Predictive collapse and reopening in a crossed‐tube configuration promote all‐ECM valves and pumps. Tissue level function is demonstrated by factors secreted from cells embedded within the tube wall, as well as endothelial or epithelial barriers lining the lumen. The described approaches are anticipated to find applications in ECM‐based organ‐on‐chip and biohybrid structures, hydraulic actuators, and soft machines.
- 4 February 2020
- Published by IOP Publishing in Biofabrication
- Vol. 12 (2) , 025002
Handheld instrument for wound-conformal delivery of skin precursor sheets improves healing in full-thickness burns
The current standard of care for patients with severe large-area burns consists of autologous skin grafting or acellular dermal substitutes. While emerging options to accelerate wound healing involve treatment with allogeneic or autologous cells, delivering cells to clinically relevant wound topologies, orientations, and sizes remains a challenge. Here, we report the one-step in situ formation of cell-containing biomaterial sheets using a handheld instrument that accommodates the topography of the wound. In an approach that maintained cell viability and proliferation, we demonstrated conformal delivery to surfaces that were inclined up to 45° with respect to the horizontal. In porcine pre-clinical models of full-thickness burn, we delivered mesenchymal stem/stromal cell-containing fibrin sheets directly to the wound bed, improving re-epithelialization, dermal cell repopulation, and neovascularization, indicating that this device could be introduced in a clinical setting improving dermal and epidermal regeneration.
- 4 February 2020
- Published by IOP Publishing in Biofabrication
- Vol. 12 (2) , 025002
Handheld instrument for wound-conformal delivery of skin precursor sheets improves healing in full-thickness burns
The current standard of care for patients with severe large-area burns consists of autologous skin grafting or acellular dermal substitutes. While emerging options to accelerate wound healing involve treatment with allogeneic or autologous cells, delivering cells to clinically relevant wound topologies, orientations, and sizes remains a challenge. Here, we report the one-step in situ formation of cell-containing biomaterial sheets using a handheld instrument that accommodates the topography of the wound. In an approach that maintained cell viability and proliferation, we demonstrated conformal delivery to surfaces that were inclined up to 45° with respect to the horizontal. In porcine pre-clinical models of full-thickness burn, we delivered mesenchymal stem/stromal cell-containing fibrin sheets directly to the wound bed, improving re-epithelialization, dermal cell repopulation, and neovascularization, indicating that this device could be introduced in a clinical setting improving dermal and epidermal regeneration.
- Top Cited Papers
- 11 April 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (10) , 1440-1451
Handheld skin printer: in situ formation of planar biomaterials and tissues
We present a handheld skin printer that enables the in situ formation of biomaterial and skin tissue sheets of different homogeneous and architected compositions. When manually positioned above a target surface, the compact instrument (weight e.g., alginate), and enzymatically cross-linkable proteins (e.g., fibrin), as well as their mixtures with collagen type I and hyaluronic acid. Upon rapid crosslinking, biomaterial and skin cell-laden sheets of consistent thickness, width and composition were obtained. Sheets deposited onto horizontal, agarose-coated surfaces were used for physical and in vitro characterization. Proof-of-principle demonstrations for the in situ formation of biomaterial sheets in murine and porcine excisional wound models illustrate the capacity of depositing onto inclined and compliant wound surfaces that are subject to respiratory motion. We expect the presented work will enable the in situ delivery of a wide range of different cells, biomaterials, and tissue adhesives, as well as the in situ fabrication of spatially organized biomaterials, tissues, and biohybrid structures.
- 11 April 2018
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (10) , 1440-1451
Top Cited PapersHandheld skin printer: in situ formation of planar biomaterials and tissues
We present a handheld skin printer that enables the in situ formation of biomaterial and skin tissue sheets of different homogeneous and architected compositions. When manually positioned above a target surface, the compact instrument (weight e.g., alginate), and enzymatically cross-linkable proteins (e.g., fibrin), as well as their mixtures with collagen type I and hyaluronic acid. Upon rapid crosslinking, biomaterial and skin cell-laden sheets of consistent thickness, width and composition were obtained. Sheets deposited onto horizontal, agarose-coated surfaces were used for physical and in vitro characterization. Proof-of-principle demonstrations for the in situ formation of biomaterial sheets in murine and porcine excisional wound models illustrate the capacity of depositing onto inclined and compliant wound surfaces that are subject to respiratory motion. We expect the presented work will enable the in situ delivery of a wide range of different cells, biomaterials, and tissue adhesives, as well as the in situ fabrication of spatially organized biomaterials, tissues, and biohybrid structures.
- 2 September 2015
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 54 (36) , 9046-9051
Peclet Number Dependence of Mass Transfer in Microscale Segmented Gas–Liquid Flow
- 2 September 2015
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 54 (36) , 9046-9051
Peclet Number Dependence of Mass Transfer in Microscale Segmented Gas–Liquid Flow
- 19 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (13) , 2842-2853
Bubble pump: scalable strategy for in-plane liquid routing
We present an on-chip liquid routing technique intended for application in well-based microfluidic systems that require long-term active pumping at low to medium flowrates. Our technique requires only one fluidic feature layer, one pneumatic control line and does not rely on flexible membranes and mechanical or moving parts. The presented bubble pump is therefore compatible with both elastomeric and rigid substrate materials and the associated scalable manufacturing processes. Directed liquid flow was achieved in a microchannel by an in-series configuration of two previously described “bubble gates”, i.e., by gas-bubble enabled miniature gate valves. Only one time-dependent pressure signal is required and initiates at the upstream (active) bubble gate a reciprocating bubble motion. Applied at the downstream (passive) gate a time-constant gas pressure level is applied. In its rest state, the passive gate remains closed and only temporarily opens while the liquid pressure rises due to the active gate's reciprocating bubble motion. We have designed, fabricated and consistently operated our bubble pump with a variety of working liquids for >72 hours. Flow rates of 0–5.5 μl min−1, were obtained and depended on the selected geometric dimensions, working fluids and actuation frequencies. The maximum operational pressure was 2.9 kPa–9.1 kPa and depended on the interfacial tension of the working fluids. Attainable flow rates compared favorably with those of available micropumps. We achieved flow rate enhancements of 30–100% by operating two bubble pumps in tandem and demonstrated scalability of the concept in a multi-well format with 12 individually and uniformly perfused microchannels (variation in flow rate <7%). We envision the demonstrated concept to allow for the consistent on-chip delivery of a wide range of different liquids that may even include highly reactive or moisture sensitive solutions. The presented bubble pump may provide active flow control for analytical and point-of-care diagnostic devices, as well as for microfluidic cells culture and organ-on-chip platforms.
- 19 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (13) , 2842-2853
Bubble pump: scalable strategy for in-plane liquid routing
We present an on-chip liquid routing technique intended for application in well-based microfluidic systems that require long-term active pumping at low to medium flowrates. Our technique requires only one fluidic feature layer, one pneumatic control line and does not rely on flexible membranes and mechanical or moving parts. The presented bubble pump is therefore compatible with both elastomeric and rigid substrate materials and the associated scalable manufacturing processes. Directed liquid flow was achieved in a microchannel by an in-series configuration of two previously described “bubble gates”, i.e., by gas-bubble enabled miniature gate valves. Only one time-dependent pressure signal is required and initiates at the upstream (active) bubble gate a reciprocating bubble motion. Applied at the downstream (passive) gate a time-constant gas pressure level is applied. In its rest state, the passive gate remains closed and only temporarily opens while the liquid pressure rises due to the active gate's reciprocating bubble motion. We have designed, fabricated and consistently operated our bubble pump with a variety of working liquids for >72 hours. Flow rates of 0–5.5 μl min−1, were obtained and depended on the selected geometric dimensions, working fluids and actuation frequencies. The maximum operational pressure was 2.9 kPa–9.1 kPa and depended on the interfacial tension of the working fluids. Attainable flow rates compared favorably with those of available micropumps. We achieved flow rate enhancements of 30–100% by operating two bubble pumps in tandem and demonstrated scalability of the concept in a multi-well format with 12 individually and uniformly perfused microchannels (variation in flow rate <7%). We envision the demonstrated concept to allow for the consistent on-chip delivery of a wide range of different liquids that may even include highly reactive or moisture sensitive solutions. The presented bubble pump may provide active flow control for analytical and point-of-care diagnostic devices, as well as for microfluidic cells culture and organ-on-chip platforms.
- 8 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (12) , 2660-2669
Artery-on-a-chip platform for automated, multimodal assessment of cerebral blood vessel structure and function
We present a compact microfluidic platform for the automated, multimodal assessment of intact small blood vessels. Mouse olfactory artery segments were reversibly loaded onto a microfluidic device and kept under physiological (i.e., close to in vivo) environmental conditions. For immunohistochemical endpoint protein analysis, automated on chip fixation and staining of the artery eliminated the need for any subsequent tissue sectioning or processing outside the chip. In a first case study, we demonstrate the blood vessel abluminal structure based on the positions of smooth muscle cell nuclei, actin filaments and voltage gated calcium channels. In a second case study we incubated smooth muscle cells (SMCs) with a calcium-sensitive dye to simultaneously assess time-dependent, agonist-induced calcium and diameter changes of pressurized resistance arteries. We expect the presented microfluidic platform to promote routine on-chip staining and quantitative fluorescence imaging of intact blood vessels from different vascular beds, tissue engineered vascular constructs and vascularized microtissues. The at least tenfold reduction in required aliquot volumes for functional assessment and staining was achieved by on-board fluid manipulation of the syringe-pump free platform and may promote its applications for screening of newly synthesized compounds.
- 8 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (12) , 2660-2669
Artery-on-a-chip platform for automated, multimodal assessment of cerebral blood vessel structure and function
We present a compact microfluidic platform for the automated, multimodal assessment of intact small blood vessels. Mouse olfactory artery segments were reversibly loaded onto a microfluidic device and kept under physiological (i.e., close to in vivo) environmental conditions. For immunohistochemical endpoint protein analysis, automated on chip fixation and staining of the artery eliminated the need for any subsequent tissue sectioning or processing outside the chip. In a first case study, we demonstrate the blood vessel abluminal structure based on the positions of smooth muscle cell nuclei, actin filaments and voltage gated calcium channels. In a second case study we incubated smooth muscle cells (SMCs) with a calcium-sensitive dye to simultaneously assess time-dependent, agonist-induced calcium and diameter changes of pressurized resistance arteries. We expect the presented microfluidic platform to promote routine on-chip staining and quantitative fluorescence imaging of intact blood vessels from different vascular beds, tissue engineered vascular constructs and vascularized microtissues. The at least tenfold reduction in required aliquot volumes for functional assessment and staining was achieved by on-board fluid manipulation of the syringe-pump free platform and may promote its applications for screening of newly synthesized compounds.
- 25 March 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (13) , 2309-2318
Shaken, and stirred: oscillatory segmented flow for controlled size-evolution of colloidal nanomaterials
We introduce oscillatory segmented flow as a compact microfluidic format that accommodates slow chemical reactions for the solution-phase processing of colloidal nanomaterials. The strategy allows the reaction progress to be monitored at a dynamic range of up to 80 decibels (i.e., residence times of up to one day, equivalent to 720–14 400 times the mixing time) from only one sensing location. A train of alternating gas bubbles and liquid reaction compartments (segmented flow) was initially formed, stopped and then subjected to a consistent back-and-forth motion. The oscillatory segmented flow was obtained by periodically manipulating the pressures at the device inlet and outlet via square wave signals generated by non-wetted solenoid valves. The readily implementable format significantly reduced the device footprint as compared with continuous segmented flow. We investigated mixing enhancement for varying liquid segment lengths, oscillation amplitudes and oscillation frequencies. The etching of gold nanorods served as a case study to illustrate the utility of the approach for dynamic characterization and precise control of colloidal nanomaterial size and shape for 5 h. Oscillatory segmented flows will be beneficial for a broad range of lab-on-a-chip applications that require long processing times.
- 25 March 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (13) , 2309-2318
Shaken, and stirred: oscillatory segmented flow for controlled size-evolution of colloidal nanomaterials
We introduce oscillatory segmented flow as a compact microfluidic format that accommodates slow chemical reactions for the solution-phase processing of colloidal nanomaterials. The strategy allows the reaction progress to be monitored at a dynamic range of up to 80 decibels (i.e., residence times of up to one day, equivalent to 720–14 400 times the mixing time) from only one sensing location. A train of alternating gas bubbles and liquid reaction compartments (segmented flow) was initially formed, stopped and then subjected to a consistent back-and-forth motion. The oscillatory segmented flow was obtained by periodically manipulating the pressures at the device inlet and outlet via square wave signals generated by non-wetted solenoid valves. The readily implementable format significantly reduced the device footprint as compared with continuous segmented flow. We investigated mixing enhancement for varying liquid segment lengths, oscillation amplitudes and oscillation frequencies. The etching of gold nanorods served as a case study to illustrate the utility of the approach for dynamic characterization and precise control of colloidal nanomaterial size and shape for 5 h. Oscillatory segmented flows will be beneficial for a broad range of lab-on-a-chip applications that require long processing times.