M. Jankowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M. Jankowski has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- M. L. Bissell
University of Manchester Manchester United Kingdom
3 shared publications - M. Piersa
University of Warsaw
3 shared publications - Magdalena Kowalska
CERN
3 shared publications - Mateusz Jerzy Chojnacki
Experimental Physics Department, CERN, 1 espl. des Particules, Geneva, Switzerland
3 shared publications - Beatrice Karg
University of Geneva Geneva Switzerland
2 shared publications D. Zakoucky
10 Nuclear Physics Institute, Czech Academy of Sciences, Rez, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Production and isomeric ratio of long-lived 11/2− xenon isomers at ISOLDE, CERN
- 18 September 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 581
Open AccessProduction and isomeric ratio of long-lived 11/2− xenon isomers at ISOLDE, CERN
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01003
Fully upgraded β -NMR setup at ISOLDE for high-precision high-field studies
β -NMR is an advancing technique that enables measurements relevant to various fields of research, ranging from physics to chemistry and biology. Among the recent achievements of the β -NMR setup located at the ISOLDE facility at CERN is the determination of the magnetic moment of a short-lived nucleus with a part-per-million accuracy. Presented here are major upgrades and extensions of that β -NMR setup. The most important advancement is the installation of a 4.7 T superconducting solenoidal magnet, leading to sub-ppm spatial homogeneity and temporal stability of the magnetic field. A detector array optimised for such magnetic field has also been implemented and a more powerful, time-resolved, fully-digital data acquisition system has been deployed. To commission the upgraded beamline, β -NMR resonances of short-lived 26 Na were recorded in solid and liquid samples. These showed 3-fold narrower linewidths and 15-fold higher resolving power than using the previous setup. Hence, the improvements achieved here permit more accurate bio- β -NMR studies, investigating, e.g., the interaction of metal ions with biomolecules, such as DNA. They also pave the way for the first studies of the distribution of the magnetisation inside short-lived nuclei.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01003
Open AccessFully upgraded β -NMR setup at ISOLDE for high-precision high-field studies
β -NMR is an advancing technique that enables measurements relevant to various fields of research, ranging from physics to chemistry and biology. Among the recent achievements of the β -NMR setup located at the ISOLDE facility at CERN is the determination of the magnetic moment of a short-lived nucleus with a part-per-million accuracy. Presented here are major upgrades and extensions of that β -NMR setup. The most important advancement is the installation of a 4.7 T superconducting solenoidal magnet, leading to sub-ppm spatial homogeneity and temporal stability of the magnetic field. A detector array optimised for such magnetic field has also been implemented and a more powerful, time-resolved, fully-digital data acquisition system has been deployed. To commission the upgraded beamline, β -NMR resonances of short-lived 26 Na were recorded in solid and liquid samples. These showed 3-fold narrower linewidths and 15-fold higher resolving power than using the previous setup. Hence, the improvements achieved here permit more accurate bio- β -NMR studies, investigating, e.g., the interaction of metal ions with biomolecules, such as DNA. They also pave the way for the first studies of the distribution of the magnetisation inside short-lived nuclei.
- Open Access
Fully upgraded $β$-NMR setup at ISOLDE for high-precision high-field studies
$β$-NMR is an advancing technique that enables measurements relevant to various fields of research, ranging from physics to chemistry and biology. Among the recent achievements of the $β$-NMR setup located at the ISOLDE facility at CERN is the determination of the magnetic moment of a shortlived nucleus with a part-per-million accuracy. Presented here are major upgrades and extensions of that $β$-NMR setup. The most important advancement is the installation of a 4.7 T superconducting solenoidal magnet, leading to sub-ppm spatial homogeneity and temporal stability of the magnetic field. A detector array optimised for such magnetic field has also been implemented and a more powerful, time-resolved, fully-digital data acquisition system has been deployed. To commission the upgraded beamline, $β$-NMR resonances of short-lived 26Na were recorded in solid and liquid samples. These showed 3-fold narrower linewidths and 15-fold higher resolving power than using the previous setup. Hence, the improvements achieved here permit more accurate bio-$β$-NMR studies, investigating, e.g., the interaction of metal ions with biomolecules, such as DNA. They also pave the way for the first studies of the distribution of the magnetisation inside short-lived nuclei.
Open AccessFully upgraded $β$-NMR setup at ISOLDE for high-precision high-field studies
$β$-NMR is an advancing technique that enables measurements relevant to various fields of research, ranging from physics to chemistry and biology. Among the recent achievements of the $β$-NMR setup located at the ISOLDE facility at CERN is the determination of the magnetic moment of a shortlived nucleus with a part-per-million accuracy. Presented here are major upgrades and extensions of that $β$-NMR setup. The most important advancement is the installation of a 4.7 T superconducting solenoidal magnet, leading to sub-ppm spatial homogeneity and temporal stability of the magnetic field. A detector array optimised for such magnetic field has also been implemented and a more powerful, time-resolved, fully-digital data acquisition system has been deployed. To commission the upgraded beamline, $β$-NMR resonances of short-lived 26Na were recorded in solid and liquid samples. These showed 3-fold narrower linewidths and 15-fold higher resolving power than using the previous setup. Hence, the improvements achieved here permit more accurate bio-$β$-NMR studies, investigating, e.g., the interaction of metal ions with biomolecules, such as DNA. They also pave the way for the first studies of the distribution of the magnetisation inside short-lived nuclei.