Maria Clara Correia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maria Clara Correia has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Francisco Serdoura
Hospital de São João, Porto, Portugal
2 shared publications - Ana Costa
Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
1 shared publication - Ana Margarida Vieira
FMUP - Faculty of Medicine of University of Porto, Porto, Portugal
1 shared publication - André Rodrigues Pinho
Department of Orthopaedics and Traumatology, ULS São João, Porto, Portugal
1 shared publication - Antônio Soares Barros
RISE-Health, Department of Surgery and Physiology, Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
1 shared publication - Bernardo Nunes
Department of Orthopedics and Traumatology, São João University Hospital Center, Porto, Portugal
1 shared publication
Latest Publications
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1201
Robotics in endoscopic spine surgery: a scoping review of clinical applications, workflow integration, and patient outcomes
- 10 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 1201
Robotics in endoscopic spine surgery: a scoping review of clinical applications, workflow integration, and patient outcomes
- Open Access
- 15 September 2026
- Published by Elsevier in Journal of Bone Oncology
- Vol. 61, 100802
Complications of vertebral augmentation in metastatic spinal fractures: a systematic review of multiple study designs
- 15 September 2026
- Published by Elsevier in Journal of Bone Oncology
- Vol. 61, 100802
Open AccessComplications of vertebral augmentation in metastatic spinal fractures: a systematic review of multiple study designs
- Open Access
- 29 December 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (2) , 100656
Functional reconstruction of complex arm defect with modified Capanna technique and latissimus dorsi muscle transfer: case report and literature review
- 29 December 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (2) , 100656
Open AccessFunctional reconstruction of complex arm defect with modified Capanna technique and latissimus dorsi muscle transfer: case report and literature review
- Open Access
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5569
Comparative Kinematic Analysis of Patellar vs. Hamstring Autografts in ACL Reconstruction on Side-Hop Test Performance
This study aimed to analyze the biomechanical differences in knees that underwent reconstruction using four-strand hamstring or bone–patellar tendon–bone autografts during the side-hop test. This case–control study included 46 participants: 18 controls, and 28 individuals who underwent reconstruction with hamstring (n = 15) or patellar (n = 13) tendons. The Theia Markerless system and Visual3D provided information on knee kinematics, namely time of contact with the ground, maximum varus and valgus angles, and flexion during maximum valgus and varus. Additionally, we assessed the activity levels of the participants pre- and post-surgery using the Tegner Activity Scale. Data analysis was conducted using ANOVA and Tukey’s post hoc test. Significant differences were observed in terms of contact time with the ground between the control and autograft groups (p = 0.025, g = −1.13; p = 0.014, g = −1.09), but not between the autograft groups. Other variables did not demonstrate statistically significant differences; however, there was a slight tendency to greater valgus in patellar autografts and greater varus with hamstring tendons. The absence of significant differences between the groups may indicate that both autografts allow knee kinematics restoration by engaging neuromuscular and proprioceptive mechanisms that compensate for anatomical alterations.
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5569
Open AccessComparative Kinematic Analysis of Patellar vs. Hamstring Autografts in ACL Reconstruction on Side-Hop Test Performance
This study aimed to analyze the biomechanical differences in knees that underwent reconstruction using four-strand hamstring or bone–patellar tendon–bone autografts during the side-hop test. This case–control study included 46 participants: 18 controls, and 28 individuals who underwent reconstruction with hamstring (n = 15) or patellar (n = 13) tendons. The Theia Markerless system and Visual3D provided information on knee kinematics, namely time of contact with the ground, maximum varus and valgus angles, and flexion during maximum valgus and varus. Additionally, we assessed the activity levels of the participants pre- and post-surgery using the Tegner Activity Scale. Data analysis was conducted using ANOVA and Tukey’s post hoc test. Significant differences were observed in terms of contact time with the ground between the control and autograft groups (p = 0.025, g = −1.13; p = 0.014, g = −1.09), but not between the autograft groups. Other variables did not demonstrate statistically significant differences; however, there was a slight tendency to greater valgus in patellar autografts and greater varus with hamstring tendons. The absence of significant differences between the groups may indicate that both autografts allow knee kinematics restoration by engaging neuromuscular and proprioceptive mechanisms that compensate for anatomical alterations.