Marie Haghebaert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marie Haghebaert has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Irene E. Vignon-Clementel
Inria, Research Center Raoul Sallé de Chou Hugues Talbot Saclay Ile-de-France Irene Vignon-Clementel France
1 shared publication - Pavlos Varsos
Inria, Research Center Saclay Ile-de-France, France
1 shared publication Roel Meiburg
Inria Research Centre Saclay Ile‐de‐France Palaiseau France
1 shared publication
Latest Publications
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Outils et méthodes pour la modélisation de la dynamique des écosystèmes microbiens complexes à partir d'observations expérimentales temporelles : application à la dynamique du microbiote intestinal
Cette thèse est issue du projet Européen Homo.symbiosus qui étudie les transitions d'équilibre des interactions entre l'hôte et son microbiote intestinal. Pour étudier les transitions nous suivons deux directions : la modélisation mécaniste des interactions hôte-microbiote et l'analyse de données temporelles de comptage microbien.Nous avons enrichi et simulé un modèle déterministe de la crypte intestinale grâce au schéma numérique EDK, en étudiant notamment l'impact des différents paramètres en utilisant la méthode des effets élémentaires de Morris. Ce modèle s'est avéré capable de simuler d'une part des états symbiotiques et dysbiotiques des interactions et d'autre part des scénarios de transition.En parallèle, un modèle EDO compartimental du colon inspiré de travaux existants a été développé et couplé au modèle de crypte. La thèse a contribué à l'enrichissement de la modélisation du métabolisme bactérien et à la modélisation de l'immunité innée à l'échelle de la muqueuse intestinale. Une exploration numérique nous a permis d'évaluer l'influence de l'alimentation sur l'état stationnaire du modèle et d'étudier l'effet d'un scénario pathologique en mimant une brèche de la barrière épithéliale.De plus, nous avons développé une approche d'analyse des données microbiennes visant à évaluer la déviation des écosystèmes microbiens subissant une forte perturbation de leur environnement par rapport à un état de référence. Cette méthode, basée sur une classification DMM, permet d'étudier les transitions d'équilibre de l'écosystème dans le cas de données avec peu d'individus et peu de points de temps. Par ailleurs, une méthode de classification de courbes utilisant le modèle SBM a été appliquée pour étudier l'effet de différentes perturbations de l'écosystème microbien, des résultats de cette étude ont pu être utilisés pour enrichir le modèle d'interactions hôte-microbiote.
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Outils et méthodes pour la modélisation de la dynamique des écosystèmes microbiens complexes à partir d'observations expérimentales temporelles : application à la dynamique du microbiote intestinal
Cette thèse est issue du projet Européen Homo.symbiosus qui étudie les transitions d'équilibre des interactions entre l'hôte et son microbiote intestinal. Pour étudier les transitions nous suivons deux directions : la modélisation mécaniste des interactions hôte-microbiote et l'analyse de données temporelles de comptage microbien.Nous avons enrichi et simulé un modèle déterministe de la crypte intestinale grâce au schéma numérique EDK, en étudiant notamment l'impact des différents paramètres en utilisant la méthode des effets élémentaires de Morris. Ce modèle s'est avéré capable de simuler d'une part des états symbiotiques et dysbiotiques des interactions et d'autre part des scénarios de transition.En parallèle, un modèle EDO compartimental du colon inspiré de travaux existants a été développé et couplé au modèle de crypte. La thèse a contribué à l'enrichissement de la modélisation du métabolisme bactérien et à la modélisation de l'immunité innée à l'échelle de la muqueuse intestinale. Une exploration numérique nous a permis d'évaluer l'influence de l'alimentation sur l'état stationnaire du modèle et d'étudier l'effet d'un scénario pathologique en mimant une brèche de la barrière épithéliale.De plus, nous avons développé une approche d'analyse des données microbiennes visant à évaluer la déviation des écosystèmes microbiens subissant une forte perturbation de leur environnement par rapport à un état de référence. Cette méthode, basée sur une classification DMM, permet d'étudier les transitions d'équilibre de l'écosystème dans le cas de données avec peu d'individus et peu de points de temps. Par ailleurs, une méthode de classification de courbes utilisant le modèle SBM a été appliquée pour étudier l'effet de différentes perturbations de l'écosystème microbien, des résultats de cette étude ont pu être utilisés pour enrichir le modèle d'interactions hôte-microbiote.
- 11 May 2025
- Published by Wiley in The Journal of Physiology
- Vol. 604 (19) , 8167-8200
A comparative study of lumped heart models for personalized medicine through sensitivity and identifiability analysis
Numerical modelling of the cardiovascular system is becoming an increasingly accepted tool for clinical applications, with the ultimate goal of personalized medicine. Lumped parameter models are attractive due to their low computational cost but often do not directly incorporate physical properties, thus requiring calibration to (often sparse) clinical data. Furthermore there exists a trade‐off between physiological relevance and model complexity, making the choice of cardiac model non‐trivial. For two established cardiac chamber models embedded in a haemodynamics whole circulation model, we perform sensitivity and identifiability analyses to examine the possibility of finding a unique subset of important parameters with varying levels of clinically measurable data, thereby examining their applicability in personalized medicine. To provide a concrete clinical context, the case of treatment planning for a young pulmonary arterial hypertension patient is considered. The methodology is however relevant for other pathophysiologies. The results suggest that the single‐fibre model, although a priori more complex than the time‐varying elastance model, is more amenable for patient‐specific modelling. This was found for representing the patient state from clinical data, defining parameter ranges for sensitivity analysis (SA), and in the results of the identifiability analysis. SA also revealed the most influential parameters, which for the right (respectively left) heart chambers, mostly affect the haemodynamics of these chambers and the pulmonary (respectively systemic) circulation but also the ones of the left (respectively right) side. This highlights the importance of studying the whole circulation, especially in diseases traditionally thought to affect only one side. image Key points: Two established cardiac chamber computational models are compared in the context of pulmonary hypertension, but the methodology holds for other pathophysiologies. Comprehensive patient‐specific data, accurate parameter ranges and thorough model validation are essential to enhance parameter identifiability, improve model personalization and eventually lead to better prediction of haemodynamic changes after clinical intervention. Due to its inherent mathematical constraints and physiologically interpretable input parameters, the single‐fibre model is easier to make patient‐specific and more accurately captures the non‐linear dynamics of ventricular pressure–volume loops than the simpler time‐varying elastance model, making it more suitable for personalized cardiac simulations. Accurate representation of both the left and right heart chambers in cardiac modelling is important, as our results suggest that parameters of each side impact the haemodynamics of the other circulatory side, making it worthwhile to measure the characteristics of both the right and left chambers, even if the disease emerges from one side.
- 11 May 2025
- Published by Wiley in The Journal of Physiology
- Vol. 604 (19) , 8167-8200
A comparative study of lumped heart models for personalized medicine through sensitivity and identifiability analysis
Numerical modelling of the cardiovascular system is becoming an increasingly accepted tool for clinical applications, with the ultimate goal of personalized medicine. Lumped parameter models are attractive due to their low computational cost but often do not directly incorporate physical properties, thus requiring calibration to (often sparse) clinical data. Furthermore there exists a trade‐off between physiological relevance and model complexity, making the choice of cardiac model non‐trivial. For two established cardiac chamber models embedded in a haemodynamics whole circulation model, we perform sensitivity and identifiability analyses to examine the possibility of finding a unique subset of important parameters with varying levels of clinically measurable data, thereby examining their applicability in personalized medicine. To provide a concrete clinical context, the case of treatment planning for a young pulmonary arterial hypertension patient is considered. The methodology is however relevant for other pathophysiologies. The results suggest that the single‐fibre model, although a priori more complex than the time‐varying elastance model, is more amenable for patient‐specific modelling. This was found for representing the patient state from clinical data, defining parameter ranges for sensitivity analysis (SA), and in the results of the identifiability analysis. SA also revealed the most influential parameters, which for the right (respectively left) heart chambers, mostly affect the haemodynamics of these chambers and the pulmonary (respectively systemic) circulation but also the ones of the left (respectively right) side. This highlights the importance of studying the whole circulation, especially in diseases traditionally thought to affect only one side. image Key points: Two established cardiac chamber computational models are compared in the context of pulmonary hypertension, but the methodology holds for other pathophysiologies. Comprehensive patient‐specific data, accurate parameter ranges and thorough model validation are essential to enhance parameter identifiability, improve model personalization and eventually lead to better prediction of haemodynamic changes after clinical intervention. Due to its inherent mathematical constraints and physiologically interpretable input parameters, the single‐fibre model is easier to make patient‐specific and more accurately captures the non‐linear dynamics of ventricular pressure–volume loops than the simpler time‐varying elastance model, making it more suitable for personalized cardiac simulations. Accurate representation of both the left and right heart chambers in cardiac modelling is important, as our results suggest that parameters of each side impact the haemodynamics of the other circulatory side, making it worthwhile to measure the characteristics of both the right and left chambers, even if the disease emerges from one side.