María Castrellón
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
María Castrellón has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Alberto Ruiz
Fundación INDICRI, Avenida Jose de la Rosa Palma, La Villa de Los Santos, Panamá
1 shared publication- Alexis Mojica
Universidad Tecnológica de Panamá
1 shared publication - Carlos A. Ho
Laboratorio de Investigación en Ingeniería y Ciencias Aplicadas, Centro Experimental de Ingeniería, Universidad Tecnológica de Panamá, Avenida Domingo Díaz, Apartado 0819-07289 El Dorado, Panamá
1 shared publication - José Fábrega
Hydraulics and Hydrotechnical Research Center, Technological University of Panamá, Panama City 0819-07289, Panama
1 shared publication - Miguel Salceda-Gonzalez
The Center for Agroforestry, School of Natural Resources, 302 Anheuser-Busch Natural Resources Building, University of Missouri, Columbia, USA
1 shared publication - Sidney Saavedra
Centro de Investigaciones Hidráulicas e Hidrotécnicas, Universidad Tecnológica de Panamá, Campus Central Dr. Víctor Levi Sasso, Edificio VIPE, Piso 1, Panamá
1 shared publication
Latest Publications
- Open Access
- 30 September 2024
- Published by Pontificia Universidad Catolica de Valparaiso in Andean geology
- Vol. 51 (3) , 475-483
Detección de roca intrusiva alterada mediante tomografía de resistividad eléctrica: El caso del área de San Luis, zona central de Panamá
This work investigates the potentiality of the 2D electrical resistivity tomography method to delineate an altered intrusive rock domain. The detection and characterization of such altered domains are crucial to understanding local hydrogeological conditions. Here, the target is the San Luis area, located in the northern part of the Estibaná River watershed, within the Los Santos Province in the central region of the Isthmus of Panama. First, a detailed geological survey was carried out to better constrain the tectonic structures. Then, two geological sections were developed based on two 2D electrical resistivity tomographies. A geoelectrical simulation process was conducted in both sections to set theoretical models whose model responses (synthetic field data set) would be consistent with the observations. After appropriate selection of the inversion parameters by using the Boundless Electrical Resistivity Tomography (BERT) code, the observations were processed, resulting in low calculation errors (2 < 0.51). Based on the superficial geological information and the results of the geophysical modelling, two profiles were established, depicting the lateral and in-depth distribution of rocks and sediments. The limit of the Ocú-Parita fault zone was identified as well. The results of the 2D inversion of the synthetic data, obtained with the established theoretical models, are consistent with the 2D inversion of the observations. Electrical resistivity tomography studies can be useful in establishing groundwater management models, particularly in areas that experience severe water scarcity during the dry season.
- 30 September 2024
- Published by Pontificia Universidad Catolica de Valparaiso in Andean geology
- Vol. 51 (3) , 475-483
Open AccessDetección de roca intrusiva alterada mediante tomografía de resistividad eléctrica: El caso del área de San Luis, zona central de Panamá
This work investigates the potentiality of the 2D electrical resistivity tomography method to delineate an altered intrusive rock domain. The detection and characterization of such altered domains are crucial to understanding local hydrogeological conditions. Here, the target is the San Luis area, located in the northern part of the Estibaná River watershed, within the Los Santos Province in the central region of the Isthmus of Panama. First, a detailed geological survey was carried out to better constrain the tectonic structures. Then, two geological sections were developed based on two 2D electrical resistivity tomographies. A geoelectrical simulation process was conducted in both sections to set theoretical models whose model responses (synthetic field data set) would be consistent with the observations. After appropriate selection of the inversion parameters by using the Boundless Electrical Resistivity Tomography (BERT) code, the observations were processed, resulting in low calculation errors (2 < 0.51). Based on the superficial geological information and the results of the geophysical modelling, two profiles were established, depicting the lateral and in-depth distribution of rocks and sediments. The limit of the Ocú-Parita fault zone was identified as well. The results of the 2D inversion of the synthetic data, obtained with the established theoretical models, are consistent with the 2D inversion of the observations. Electrical resistivity tomography studies can be useful in establishing groundwater management models, particularly in areas that experience severe water scarcity during the dry season.