Yazhou Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yazhou Zhao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Guoyang Liu
Shenzhen Research Institute of Shandong University, Shenzhen 518000, China
6 shared publications - Weidong Zhou
Shandong University
6 shared publications - Lan Tian
Shandong University
2 shared publications - Zhuohan Wang
School of Integrated Circuits, Shandong University, Jinan 250101, China
2 shared publications - Chengyang Yan
School of Integrated Circuits, Shandong University, Jinan 250101, China
1 shared publication - Guanghao Jin
Shandong University China
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (15) , 7834
Explainable Artificial Intelligence Technology and Its Applications: Toward Transparent, Human-Centered, and Trustworthy AI
Explainable artificial intelligence (XAI) has become a central methodology for developing transparent, accountable, and human-centered AI systems. As data-driven models are increasingly deployed in high-stakes and socially consequential settings, explanations are expected not only to illuminate model behavior but also to support validation, error analysis, fairness auditing, regulatory compliance, and effective human–AI collaboration. This Editorial introduces the Special Issue “Explainable Artificial Intelligence Technology and Its Applications” and situates its contributions within the broader trajectory of XAI research. We briefly review major methodological families, including intrinsic interpretability, local surrogate and Shapley-value explanations, gradient- and perturbation-based visual attribution, counterfactual and causal explanations, and human-centered evaluation. We then highlight representative contributions in this Special Issue, which demonstrate how XAI is moving from generic explanation visualizations toward domain-sensitive, data-aware, and operationally reliable methods in network security, computer vision, knowledge graphs, and financial decision support. Finally, we discuss future directions, emphasizing faithful and plausible explanations, causal and multimodal reasoning, real-time and hardware-efficient deployment, trustworthy governance, and the emerging role of XAI in education.
- 6 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (15) , 7834
Open AccessExplainable Artificial Intelligence Technology and Its Applications: Toward Transparent, Human-Centered, and Trustworthy AI
Explainable artificial intelligence (XAI) has become a central methodology for developing transparent, accountable, and human-centered AI systems. As data-driven models are increasingly deployed in high-stakes and socially consequential settings, explanations are expected not only to illuminate model behavior but also to support validation, error analysis, fairness auditing, regulatory compliance, and effective human–AI collaboration. This Editorial introduces the Special Issue “Explainable Artificial Intelligence Technology and Its Applications” and situates its contributions within the broader trajectory of XAI research. We briefly review major methodological families, including intrinsic interpretability, local surrogate and Shapley-value explanations, gradient- and perturbation-based visual attribution, counterfactual and causal explanations, and human-centered evaluation. We then highlight representative contributions in this Special Issue, which demonstrate how XAI is moving from generic explanation visualizations toward domain-sensitive, data-aware, and operationally reliable methods in network security, computer vision, knowledge graphs, and financial decision support. Finally, we discuss future directions, emphasizing faithful and plausible explanations, causal and multimodal reasoning, real-time and hardware-efficient deployment, trustworthy governance, and the emerging role of XAI in education.
- Open Access
A Learnable Entropy-Power Scaling Transform with a Radial Basis Function Network for Electroencephalography-Based Familiar and Unfamiliar Face Classification
Familiar and unfamiliar face recognition is an important cognitive process with potential applications in brain-computer interface (BCI) systems and neurocognitive assessment. Classification of familiar and unfamiliar faces based on electroencephalography (EEG) remains challenging because discriminative information is distributed across multiple frequency bands, temporal windows, and scalp channels. This study proposes LEPST-RBFNet, which combines a Learnable Entropy-Power Scaling Transform (LEPST) and a radial basis function (RBF) network for EEG-based familiar and unfamiliar face classification. The model first segments the EEG into multi-scale time-frequency segments and then extracts local standard-deviation features. After that, a learnable entropy-power-inspired scaling transformation is applied using the LEPST module to obtain adaptive local time-frequency EEG entropy features. The transformed features are classified by an RBF prototype module with learnable centers and an adaptive kernel-width parameter. Experiments using a five-fold leave-one-block-out validation protocol show that LEPST-RBFNet achieves a superior average classification accuracy of 73.60%. Ablation and visualization analyses further indicate that the proposed model provides a competitive and interpretable framework for EEG-based familiar and unfamiliar face recognition.
Open AccessA Learnable Entropy-Power Scaling Transform with a Radial Basis Function Network for Electroencephalography-Based Familiar and Unfamiliar Face Classification
Familiar and unfamiliar face recognition is an important cognitive process with potential applications in brain-computer interface (BCI) systems and neurocognitive assessment. Classification of familiar and unfamiliar faces based on electroencephalography (EEG) remains challenging because discriminative information is distributed across multiple frequency bands, temporal windows, and scalp channels. This study proposes LEPST-RBFNet, which combines a Learnable Entropy-Power Scaling Transform (LEPST) and a radial basis function (RBF) network for EEG-based familiar and unfamiliar face classification. The model first segments the EEG into multi-scale time-frequency segments and then extracts local standard-deviation features. After that, a learnable entropy-power-inspired scaling transformation is applied using the LEPST module to obtain adaptive local time-frequency EEG entropy features. The transformed features are classified by an RBF prototype module with learnable centers and an adaptive kernel-width parameter. Experiments using a five-fold leave-one-block-out validation protocol show that LEPST-RBFNet achieves a superior average classification accuracy of 73.60%. Ablation and visualization analyses further indicate that the proposed model provides a competitive and interpretable framework for EEG-based familiar and unfamiliar face recognition.
- Open Access
- 27 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (13) , 2012
Power and Phase Fusion Spectrogram with Three-Dimensional Convolution and Vision Transformer for Seizure Detection
Background/Objectives: Reliable detection of epileptic seizures using electroencephalography (EEG) is crucial for clinical diagnosis and for alleviating clinicians’ workload. However, existing studies still make insufficient use of phase information, and the synergy between local time–frequency pattern extraction and global dependency modeling remains limited. Methods: We propose a seizure detection framework based on the continuous wavelet transform (CWT), a three-dimensional convolutional neural network (3D-CNN), and a vision transformer (ViT). First, multichannel EEG segments are preprocessed, after which CWT is used to generate power spectrograms and phase spectrograms. These representations are then fused along the depth dimension into a unified power-phase volume and fed into a hybrid network composed of a 3D-CNN feature extractor and a single-layer ViT encoder to jointly learn local time–frequency–channel coupling patterns and higher-level global dependencies. Finally, seizure detection is completed by combining moving-average filtering, thresholding, and collar correction. Results: On the public CHB-MIT dataset and the clinical SH-SDU dataset, the proposed method achieved average segment-level sensitivities of 98.68% and 92.05%, specificities of 98.33% and 97.53%, accuracies of 98.49% and 96.37%, and AUC values of 97.26% and 92.89%, respectively. In event-level evaluation, the average sensitivities were 99.13% and 96.08%, with false detection rates of 0.88/h and 0.69/h, respectively. Further multi-stage ablation experiments together with t-SNE and Grad-CAM visualizations provided qualitative and experimental support for the design rationale of the joint power-phase input and the hybrid 3D-CNN-ViT architecture. Conclusions: The proposed framework effectively exploits the complementary discriminative value of power and phase information in epileptic EEG and demonstrates strong detection performance under patient-specific evaluation on both public and clinically collected datasets.
- 27 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (13) , 2012
Open AccessPower and Phase Fusion Spectrogram with Three-Dimensional Convolution and Vision Transformer for Seizure Detection
Background/Objectives: Reliable detection of epileptic seizures using electroencephalography (EEG) is crucial for clinical diagnosis and for alleviating clinicians’ workload. However, existing studies still make insufficient use of phase information, and the synergy between local time–frequency pattern extraction and global dependency modeling remains limited. Methods: We propose a seizure detection framework based on the continuous wavelet transform (CWT), a three-dimensional convolutional neural network (3D-CNN), and a vision transformer (ViT). First, multichannel EEG segments are preprocessed, after which CWT is used to generate power spectrograms and phase spectrograms. These representations are then fused along the depth dimension into a unified power-phase volume and fed into a hybrid network composed of a 3D-CNN feature extractor and a single-layer ViT encoder to jointly learn local time–frequency–channel coupling patterns and higher-level global dependencies. Finally, seizure detection is completed by combining moving-average filtering, thresholding, and collar correction. Results: On the public CHB-MIT dataset and the clinical SH-SDU dataset, the proposed method achieved average segment-level sensitivities of 98.68% and 92.05%, specificities of 98.33% and 97.53%, accuracies of 98.49% and 96.37%, and AUC values of 97.26% and 92.89%, respectively. In event-level evaluation, the average sensitivities were 99.13% and 96.08%, with false detection rates of 0.88/h and 0.69/h, respectively. Further multi-stage ablation experiments together with t-SNE and Grad-CAM visualizations provided qualitative and experimental support for the design rationale of the joint power-phase input and the hybrid 3D-CNN-ViT architecture. Conclusions: The proposed framework effectively exploits the complementary discriminative value of power and phase information in epileptic EEG and demonstrates strong detection performance under patient-specific evaluation on both public and clinically collected datasets.
- Open Access
- 27 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 754
CosFNet: A Lightweight Epileptic EEG Detection Model Based on Cosine Convolution and FNet
Background/Objectives: Epilepsy is a prevalent chronic neurological disorder, and electroencephalography (EEG) remains essential for its diagnosis and long-term monitoring. Although deep learning-based automatic seizure detection has advanced considerably, existing models typically require extensive parameters and computational resources, limiting their deployment on resource-constrained platforms. Methods: In this study, we propose CosFNet, a hybrid lightweight architecture integrating cosine convolution with an FNet encoder, a Fourier-transform-based token-mixing encoder. The cosine convolution frontend parameterizes convolutional kernels with the cosine function to efficiently capture local spatiotemporal features. The FNet backend replaces traditional self-attention with a parameter-free two-dimensional discrete Fourier transform, enabling global mixing across temporal tokens and hidden feature dimensions with fast Fourier transform-based efficiency. With these advances, the model contains only 19,458 learnable parameters. Results: On the publicly available CHB-MIT dataset, CosFNet achieves a mean segment-level sensitivity of 97.60%, a specificity of 97.12%, an event-level sensitivity of 98.59%, a false detection rate (FDR) of 0.82/h, and an area under the receiver operating characteristic curve (AUC) of 97.87%. On our collected SH-SDU dataset, it attains a mean sensitivity of 92.87%, specificity of 94.74%, an event-level sensitivity of 99.41%, and an AUC of 96.29%. Conclusions: CosFNet achieves competitive detection performance with significantly low complexity, offering a viable pathway toward clinical deployment in resource-limited environments.
- 27 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 754
Open AccessCosFNet: A Lightweight Epileptic EEG Detection Model Based on Cosine Convolution and FNet
Background/Objectives: Epilepsy is a prevalent chronic neurological disorder, and electroencephalography (EEG) remains essential for its diagnosis and long-term monitoring. Although deep learning-based automatic seizure detection has advanced considerably, existing models typically require extensive parameters and computational resources, limiting their deployment on resource-constrained platforms. Methods: In this study, we propose CosFNet, a hybrid lightweight architecture integrating cosine convolution with an FNet encoder, a Fourier-transform-based token-mixing encoder. The cosine convolution frontend parameterizes convolutional kernels with the cosine function to efficiently capture local spatiotemporal features. The FNet backend replaces traditional self-attention with a parameter-free two-dimensional discrete Fourier transform, enabling global mixing across temporal tokens and hidden feature dimensions with fast Fourier transform-based efficiency. With these advances, the model contains only 19,458 learnable parameters. Results: On the publicly available CHB-MIT dataset, CosFNet achieves a mean segment-level sensitivity of 97.60%, a specificity of 97.12%, an event-level sensitivity of 98.59%, a false detection rate (FDR) of 0.82/h, and an area under the receiver operating characteristic curve (AUC) of 97.87%. On our collected SH-SDU dataset, it attains a mean sensitivity of 92.87%, specificity of 94.74%, an event-level sensitivity of 99.41%, and an AUC of 96.29%. Conclusions: CosFNet achieves competitive detection performance with significantly low complexity, offering a viable pathway toward clinical deployment in resource-limited environments.
- Open Access
- 30 May 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (6) , 377
PG-MCTFormer: A Prior-Guided Multi-Scale Convolutional Transformer for Interpretable Motor Imagery EEG Classification
Motor imagery brain–computer interfaces (MI-BCIs) have important applications in neurorehabilitation, assistive communication, and non-muscular human–machine interaction. From a bionic neural-interfacing perspective, MI-BCI decoding provides a computational bridge between biological motor intention and external machine control. However, reliable motor imagery electroencephalography (MI-EEG) classification remains challenging due to the highly non-stationary features of MI-EEG and limited interpretability. In this work, we propose PG-MCTFormer, a prior-guided multi-scale convolutional Transformer for MI-EEG classification that integrates rhythm-aware temporal filtering, dual-scale spatial modeling, and contextual decoding within a unified architecture. We evaluated the model on the publicly available BCI Competition IV 2a dataset, achieving 85.08% average accuracy and a Cohen’s kappa of 0.80, with significant performance improvement over the traditional methods. Comprehensive multi-view interpretability analyses in the frequency, temporal, and spatial domains further show that the learned filters remain aligned with canonical MI-related bands, discriminative evidence concentrates in the middle-to-late imagery interval, and the spatial prior is refined into subject-adaptive sensorimotor topographic patterns. These results indicate that explicit neurophysiological priors can improve both the robustness and the interpretability of MI-EEG decoders for biomimetic neural-interface applications.
- 30 May 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (6) , 377
Open AccessPG-MCTFormer: A Prior-Guided Multi-Scale Convolutional Transformer for Interpretable Motor Imagery EEG Classification
Motor imagery brain–computer interfaces (MI-BCIs) have important applications in neurorehabilitation, assistive communication, and non-muscular human–machine interaction. From a bionic neural-interfacing perspective, MI-BCI decoding provides a computational bridge between biological motor intention and external machine control. However, reliable motor imagery electroencephalography (MI-EEG) classification remains challenging due to the highly non-stationary features of MI-EEG and limited interpretability. In this work, we propose PG-MCTFormer, a prior-guided multi-scale convolutional Transformer for MI-EEG classification that integrates rhythm-aware temporal filtering, dual-scale spatial modeling, and contextual decoding within a unified architecture. We evaluated the model on the publicly available BCI Competition IV 2a dataset, achieving 85.08% average accuracy and a Cohen’s kappa of 0.80, with significant performance improvement over the traditional methods. Comprehensive multi-view interpretability analyses in the frequency, temporal, and spatial domains further show that the learned filters remain aligned with canonical MI-related bands, discriminative evidence concentrates in the middle-to-late imagery interval, and the spatial prior is refined into subject-adaptive sensorimotor topographic patterns. These results indicate that explicit neurophysiological priors can improve both the robustness and the interpretability of MI-EEG decoders for biomimetic neural-interface applications.
- Open Access
- 16 May 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (5) , 509
EEG-Based Seizure Detection Using Dual-Branch CNN-ViT Network Integrating Phase and Power Spectrograms
Background/Objectives: Epilepsy is a common neurological disorder with pathological mechanisms closely associated with the spatiotemporal dynamic characteristics of electroencephalogram (EEG) signals. Although significant progress has been made in epileptic seizure detection methods using time–frequency analysis, current research still faces challenges in terms of an insufficient utilization of phase information. Methods: In this study, we propose an effective epileptic seizure detection framework based on continuous wavelet transform (CWT) and a hybrid network consisting of convolutional neural network (CNN) and vision transformer (ViT). First, the raw EEG signals are processed by the CWT. Then, the phase spectrogram and power spectrogram of the EEG are generated, and they are sent into the designed CNN and ViT branches of the network to extract more discriminative EEG features. Finally, the features output from the two branches are fused and fed into the classification network to obtain the detection results. Results: Experimental results on the CHB-MIT public dataset and our SH-SDU clinical dataset show that the proposed framework achieves sensitivities of 98.09% and 89.02%, specificities of 98.21% and 95.46%, and average accuracies of 98.45% and 94.66%, respectively. Furthermore, we compared the spectral characteristics of CWT with other time–frequency transforms within the hybrid architecture, demonstrating the advantages of the CWT-based CNN-ViT architecture. Conclusions: These results highlight the outstanding epileptic seizure detection performance of the proposed framework and its significant clinical feasibility.
- 16 May 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (5) , 509
Open AccessEEG-Based Seizure Detection Using Dual-Branch CNN-ViT Network Integrating Phase and Power Spectrograms
Background/Objectives: Epilepsy is a common neurological disorder with pathological mechanisms closely associated with the spatiotemporal dynamic characteristics of electroencephalogram (EEG) signals. Although significant progress has been made in epileptic seizure detection methods using time–frequency analysis, current research still faces challenges in terms of an insufficient utilization of phase information. Methods: In this study, we propose an effective epileptic seizure detection framework based on continuous wavelet transform (CWT) and a hybrid network consisting of convolutional neural network (CNN) and vision transformer (ViT). First, the raw EEG signals are processed by the CWT. Then, the phase spectrogram and power spectrogram of the EEG are generated, and they are sent into the designed CNN and ViT branches of the network to extract more discriminative EEG features. Finally, the features output from the two branches are fused and fed into the classification network to obtain the detection results. Results: Experimental results on the CHB-MIT public dataset and our SH-SDU clinical dataset show that the proposed framework achieves sensitivities of 98.09% and 89.02%, specificities of 98.21% and 95.46%, and average accuracies of 98.45% and 94.66%, respectively. Furthermore, we compared the spectral characteristics of CWT with other time–frequency transforms within the hybrid architecture, demonstrating the advantages of the CWT-based CNN-ViT architecture. Conclusions: These results highlight the outstanding epileptic seizure detection performance of the proposed framework and its significant clinical feasibility.