YZYubin Zhao

Yubin Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yubin Zhao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • He Zhang

    School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, China

    2 shared publications
  • Xiufeng Guo

    College of Atmosphere and Remote Sensing, Wuxi University, Wuxi 214105, China

    2 shared publications
  • Yuhang Zheng

    School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, China

    2 shared publications
  • Zhaoxia Wang

    School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, China

    2 shared publications
  • Bin Wu

    State Key Laboratory of Severe Weather & CMA Key Laboratory of Lightning, Chinese Academy of Meteorological Sciences, Beijing 100081, China

    1 shared publication
  • Nian Zhao

    School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 211544, China

    1 shared publication

Latest Publications

  • Open Access

    Study on the Characteristics of Positive and Negative Corona Discharge of an Independent Lightning Rod Under Different Background Electric Field Amplitude

    by He Zhang, Xiufeng Guo, Zhaoxia Wang, Yubin Zhao, Yuhang Zheng, Shijie Liu

    Corona discharge at the tip of buildings in a thunderstorm environment is an important factor causing changes in the near-ground electric field, but the influence of a quadratic growth law and quantitative research on the parameters is still rare. Therefore, based on the three-dimensional corona discharge model, this paper studies the influence of positive and negative symmetrical triangular wave electric fields with different amplitudes on the corona discharge of an independent lightning rod. Studies have shown that the corona current is synchronized with the peak of the background electric field. Studies have shown that the corona current is synchronized with the peak of the background electric field. When the polarity of the electric field changes from positive to negative, the positive charge accumulated in the positive half-cycle promotes the subsequent negative corona, so the negative corona starts in advance when the polarity reverses. Compared with unipolar discharge, the amplitude of the negative current and the number of negative charges have significantly improved. However, due to the counteraction of neutralization between positive and negative charges, the total corona charge is at a low level, which shows a net negative polarity result. The corona current and the amount of charge increase nonlinearly with an increase in the background electric field amplitude. Under the symmetrical triangular wave electric field, the quantitative fitting relationship between the peak value of the negative corona current in the second half-cycle and the amount of charge is established for the 5 m high independent lightning rod, which is I− = −0.0532 − 0.153 E − 0.0682 E2, Q− = −3.18 × 10−3 + 7.762 × 10−4E − 4.671 × 10−5 E2, respectively. The increase in the background electric field amplitude will aggravate the disturbance of the corona discharge to the near-surface electric field. When the direction of the electric field has reverted to zero, the existence of the space charge will lead to a significant change in the strength and polarity of the ground electric field. When the thunderstorm background electric field changes from positive to negative, the corona effect reverses the polarity of the ground electric field in advance, and the larger the peak value of the background electric field, the larger the advance. The corona interference mechanism revealed by this study can provide an important reference for correcting the electric field monitoring data and improving the accuracy of lightning warnings.


  • Open Access

    The Development and Application of a Three-Dimensional Corona Discharge Numerical Model Considering the Thunderstorm Electric Field Polarity Reversal Process

    by Zhaoxia Wang, Bin Wu, Xiufeng Guo, Nian Zhao, He Zhang, Yubin Zhao, Yuhang Zheng

    The study of the ground tip corona discharge is an important part of the lightning strike mechanism and lightning warning research. Because the characteristics of the corona charge distribution are difficult to observe directly, simulation research is indispensable. However, most of the previous models have been unipolar models, which cannot reflect the characteristics of the tip corona discharge under electric field reversal during real thunderstorms. Therefore, the development of three-dimensional positive and negative corona discharge models is of great significance. In this study, a three-dimensional corona discharge numerical model considering the polarity reversal process of the electric field was developed with or without a wind field and simulated the tip corona discharge characteristics under this reversal. The reliability of the model was verified by comparing the observed results. Compared with the unipolar corona discharge model, this model could effectively evaluate the impact of the first half-cycle corona discharge on the second half-cycle opposite-polarity corona discharge and invert the spatial separation distribution characteristics of different polar corona charges released in both cycles under the influence of wind and the spatial electric field distribution characteristics generated by the corresponding corona charges. Comparing unipolar corona discharges under the same wave pattern and amplitude of the background electric field, it was assumed that the unipolar corona discharge occurred in the half cycle after the polarity reversal of an electric field, and there was also an opposite-polarity corona discharge process before it. Due to the influence of the first half cycle, the background electric field required for a corona discharge was smaller, and the corona current was generated earlier, but the end time was equivalent. At the same time, due to the neutralization effect of positive and negative corona charges, the peak value of the total corona charge in the second half cycle was significantly smaller than that of the unipolar model. At different building heights, the peak difference in the corona current and the peak difference in the corona charge between the two models increased linearly with an increase in height. It could be seen that this model had better simulation results and wider application value.