Ang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ang Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Anning Hu
Shanghai Key Laboratory of Navigation and Location-based Service, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Danping Zou
Shanghai Jiao Tong University
1 shared publication Dexin Zuo
Shanghai Key Laboratory of Navigation and Location-based Service, Shanghai Jiao Tong University, Shanghai, China
1 shared publication- Guohua Cheng
School of Pharmacy, Jinan University, Guangzhou, China
1 shared publication - Jianshe Tang
Department of Environmental and Energy Engineering, Anhui Jianzhu University, Hefei, People’s Republic of China
1 shared publication - Min Zhang
Department of Forestry College of Forestry, Northwest A & F University Yangling PR China
1 shared publication
Latest Publications
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (10) , 9748-9762
Sparse-to-Dense Hint Guided Stereo-LiDAR Fusion
One challenge in stereo-LiDAR fusion arises from the sparsity and non-uniform distribution of LiDAR data. Existing methods expand sparse LiDAR data to produce semi-dense hints as guidance for fusion. However, the absence of depth cues beyond the expanded areas may still limit performance. To address this challenge, we propose a novel sparse-to-dense hint guided stereo-LiDAR fusion method. The key idea is to use a dense hint map generated by a lightweight network as guidance, with sparse LiDAR points and a monocular image as inputs. The dense hints are then employed to construct and explicitly regularize a multi-modal cost volume via integrating the geometric cues from the hints and the visual information from the images to produce better stereo prediction. The construction and aggregation of cost volume follow a well-designed coarse-to-fine strategy along with a pixel-wise search range adjustment module, facilitating fast computation while preserving fine details. Finally, a confidence-based fusion module is performed to adaptively produce the ultimate prediction based on the monocular and stereo estimations. The experimental results show that our method significantly outperforms existing methods with high inference efficiency across multiple benchmark datasets. To contribute to the community, we will release the code at: https://github.com/LiAngLA66/DG-Fusion.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (10) , 9748-9762
Sparse-to-Dense Hint Guided Stereo-LiDAR Fusion
One challenge in stereo-LiDAR fusion arises from the sparsity and non-uniform distribution of LiDAR data. Existing methods expand sparse LiDAR data to produce semi-dense hints as guidance for fusion. However, the absence of depth cues beyond the expanded areas may still limit performance. To address this challenge, we propose a novel sparse-to-dense hint guided stereo-LiDAR fusion method. The key idea is to use a dense hint map generated by a lightweight network as guidance, with sparse LiDAR points and a monocular image as inputs. The dense hints are then employed to construct and explicitly regularize a multi-modal cost volume via integrating the geometric cues from the hints and the visual information from the images to produce better stereo prediction. The construction and aggregation of cost volume follow a well-designed coarse-to-fine strategy along with a pixel-wise search range adjustment module, facilitating fast computation while preserving fine details. Finally, a confidence-based fusion module is performed to adaptively produce the ultimate prediction based on the monocular and stereo estimations. The experimental results show that our method significantly outperforms existing methods with high inference efficiency across multiple benchmark datasets. To contribute to the community, we will release the code at: https://github.com/LiAngLA66/DG-Fusion.
- 31 October 2008
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 43 (8) , 707-712
Development of IC-ELISA for detection of organophosphorus pesticides in water
Diethyl (carboxymethyl) phosphonate (DECP) was used as the hapten to develop an indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) for detecting organophosphorus pesticides (OPs). Conjugator of DECP with bovin serum albumin (BSA) was used as the immunogen for producing the polyclonal antibodies (PcAbs). Three antisera were obtained after the immune procedure. Characterization studies of the PcAbs indicated that the titer of antiserum-1 was highest in 3 antisera, and antiserum-1 had high affinity and specificity to the parathion, dichlorvos and pirimiphos. The IC-ELISA showed an IC50 of 0.428 micro g/mL with a detection limit of 0.0125 micro g/mL to parathion. The assay also indicated that the IC50 values of pirimiphos and dichlorvos were 0.331 micro g/mL and 1.25 micro g/mL respectively, and the detection limits of pirimiphos and dichlorvos were 0.0116 micro g/mL and 0.048 micro g/mL respectively. Recoveries of parathion, pirimiphos and dichlorvos spiked into water samples ranged from 90% to 160%. The results indicated that the ELISA could be a convenient and supplemental analytical tool for monitoring OPs residues in environmental water samples.
- 31 October 2008
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 43 (8) , 707-712
Development of IC-ELISA for detection of organophosphorus pesticides in water
Diethyl (carboxymethyl) phosphonate (DECP) was used as the hapten to develop an indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) for detecting organophosphorus pesticides (OPs). Conjugator of DECP with bovin serum albumin (BSA) was used as the immunogen for producing the polyclonal antibodies (PcAbs). Three antisera were obtained after the immune procedure. Characterization studies of the PcAbs indicated that the titer of antiserum-1 was highest in 3 antisera, and antiserum-1 had high affinity and specificity to the parathion, dichlorvos and pirimiphos. The IC-ELISA showed an IC50 of 0.428 micro g/mL with a detection limit of 0.0125 micro g/mL to parathion. The assay also indicated that the IC50 values of pirimiphos and dichlorvos were 0.331 micro g/mL and 1.25 micro g/mL respectively, and the detection limits of pirimiphos and dichlorvos were 0.0116 micro g/mL and 0.048 micro g/mL respectively. Recoveries of parathion, pirimiphos and dichlorvos spiked into water samples ranged from 90% to 160%. The results indicated that the ELISA could be a convenient and supplemental analytical tool for monitoring OPs residues in environmental water samples.