Xie Cherng Miow
Xie Cherng Miow has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dylon Hao Cheng Lam
Department of Renewable Energy, PETRONAS Research Sdn Bhd, Kajang, Selangor, Malaysia
1 shared publication Hamzah B. Adlan
Department of Renewable Energy, PETRONAS Research Sdn Bhd, Kajang, Selangor, Malaysia
1 shared publication- Jianhui Wong
Universiti Tunku Abdul Rahman
1 shared publication - Lee Cheun Hau
Electrical and Electronic Engineering Department, Universiti Tunku Abdul Rahman, Kajang, Selangor, Malaysia
1 shared publication - Mahmudul Hasan
Electrical and Electronic Engineering Department, Universiti Tunku Abdul Rahman, Kajang, Selangor, Malaysia
1 shared publication Nor Shahida Hasan
Department of Renewable Energy, PETRONAS Research Sdn Bhd, Kajang, Selangor, Malaysia
1 shared publication
Latest Publications
- Open Access
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 87582-87599
An Innovative Adaptive Threshold-Based BESS Controller Utilizing Deep Learning Forecast for Peak Demand Reductions
Battery-based energy storage systems (BESS) can be installed and controlled by a control strategy to reduce daily peak demands. Majority of the existing controllers for BESS is developed and studied on a simulation platform. Hence, an innovative adaptive threshold-based controller is developed and implemented on a real 200 kWh BESS installed on a university campus in Malaysia to reduce daily peak demands. This controller is developed on the free, open-source Node-RED platform using a deep learning-based one-dimensional convolution neural network (1D-CNN) to forecast the load profile for one day ahead. The controller uses the forecasted load profile to define a threshold or specific power demand level above which the BESS will start discharging power to meet the demand. The threshold is actively adjusted according to the actual and forecasted power demand of the customer as well as preceding peak of the grid power. The performance of the controller is initially assessed through six months of comprehensive simulations, where its daily peak reduction factor (Kpdr) and monthly peak reduction failure rate (ηfailure) are compared with that of two fixed-threshold controllers, namely forecasted threshold and historical threshold-based controllers, and another two advanced controllers, namely active and fuzzy controllers. The adaptive threshold-based controller achieves an average Kpdr of 41.62% and ηfailure of just 16.55%, which are better than that of other four controllers. The controller is implemented to BESS in a university building to evaluate its practical performance over 21 days under a real operating condition. The controller achieves an average Kpdr of 49.45% with a ηfailure of just 4.76%, which are better than the simulation results.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 87582-87599
Open AccessAn Innovative Adaptive Threshold-Based BESS Controller Utilizing Deep Learning Forecast for Peak Demand Reductions
Battery-based energy storage systems (BESS) can be installed and controlled by a control strategy to reduce daily peak demands. Majority of the existing controllers for BESS is developed and studied on a simulation platform. Hence, an innovative adaptive threshold-based controller is developed and implemented on a real 200 kWh BESS installed on a university campus in Malaysia to reduce daily peak demands. This controller is developed on the free, open-source Node-RED platform using a deep learning-based one-dimensional convolution neural network (1D-CNN) to forecast the load profile for one day ahead. The controller uses the forecasted load profile to define a threshold or specific power demand level above which the BESS will start discharging power to meet the demand. The threshold is actively adjusted according to the actual and forecasted power demand of the customer as well as preceding peak of the grid power. The performance of the controller is initially assessed through six months of comprehensive simulations, where its daily peak reduction factor (Kpdr) and monthly peak reduction failure rate (ηfailure) are compared with that of two fixed-threshold controllers, namely forecasted threshold and historical threshold-based controllers, and another two advanced controllers, namely active and fuzzy controllers. The adaptive threshold-based controller achieves an average Kpdr of 41.62% and ηfailure of just 16.55%, which are better than that of other four controllers. The controller is implemented to BESS in a university building to evaluate its practical performance over 21 days under a real operating condition. The controller achieves an average Kpdr of 49.45% with a ηfailure of just 4.76%, which are better than the simulation results.