ECEni Cahyaningsih

Eni Cahyaningsih

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article



Latest Publications

  • Open Access

    Validasi Metode Deteksi Shigella dalam Tablet Hisap Obat Kuasi

    by Desty Herawati, Eko Aprianto, Eni Cahyaningsih, Nur Miftahurrohmah

    Tablet hisap obat kuasi yang digunakan untuk meredakan sakit tenggorokan harus memenuhi persyaratan keamanan dan mutu sesuai Peraturan Badan POM No. 7 Tahun 2023 tentang kriteria dan tata laksana registrasi obat kuasi, yang menetapkan bahwa sediaan oral obat kuasi harus bebas dari cemaran mikroba Shigella spp. Kontaminasi oleh bakteri Shigella dapat menyebabkan penyakit seperti shigellosis yang ditandai dengan gejala seperti diare, muntah, dan demam. Penelitian ini bertujuan untuk memvalidasi metode deteksi Shigella spp. pada tablet hisap obat kuasi menggunakan metode acuan WHO (Quality Control Methods for Herbal Materials). Validasi dilakukan untuk memastikan metode ini dapat digunakan untuk analisis rutin di laboratorium BPOM. Pedoman yang digunakan untuk memvalidasi metode mikrobiologi adalah Singapore Accreditation Council (SAC) Guidance Notes C&B AND ENV 002 Tahun 2019 serta farmakope. Hasil penelitian menunjukkan bahwa metode WHO (Quality Control Methods for Herbal Materials) dalam mendeteksi Shigella sp. memiliki sensitivitas dan spesifisitas sebesar 100%, dengan tingkat positif palsu dan negatif palsu masing-masing 0%. Limit deteksi yang diperoleh adalah 3 cfu/g, yang memenuhi persyaratan (di bawah 10 cfu/g). Dari uji kesesuaian metode (optimasi) yang dilakukan menunjukkan bahwa pelarut awal yang digunakan untuk homogenisasi sampel pada deteksi Shigella cukup menggunakan Tryptone Soya Broth (1:10) tanpa perlu prosedur penetralan atau modifikasi tambahan pada tahapan homogenisasi sampel. Berdasarkan hasil ini, metode deteksi Shigella spp. menggunakan metode acuan WHO (Quality Control Methods for Herbal Materials) dinyatakan akurat dan dapat diterapkan untuk analisis rutin pengujian cemaran mikroba di laboratorium-laboratorium Badan Pengawas Obat dan Makanan.


  • Open Access

    Performance Characteristics of the Quantitative Method for Staphylococcus aureus in Food Products Correspond to ISO 16140-3: 2021

    by Fannisa Putri, Sri Surati, Aditya Anugerah Marusaha Sitorus, Kemala Suardi Nagur, Eni Cahyaningsih, Yulin Wilasti, Maria Arieni Eka Devina Sihotang

    Staphylococcus aureus is a pathogenic bacterium that poses significant health risks when present in food products. High levels of Staphylococcus aureus in food can indicate poor hygiene and handling practices during food production, processing, or storage. In order to maintain food safety and quality, verification of the quantitative method of Staphylococcus aureus is very important. Method verification represents a crucial stage in guaranteeing that all employed procedures conform to the necessary criteria for dependable and precise data. Following the guidelines established in ISO 16140-3:2021, method verification is accomplished through the calculation of the Intralaboratory Reproducibility Standard Deviation (SIR) for implementation validation and the eBias value for verifying the suitability of the method for assessing specific food items. This research was conducted with the objective of confirming the ISO 6888-1:2021 as the designated reference method for quantifying Staphylococcus aureus in food products. For the purpose of confirming the implementation of the method, Cheese was utilized as the test food item. In the context of verifying the method's applicability to different food products, a range of items including condensed milk, margarine, baby porridge, cassava chips and ready-to-eat sausage were examined as challenging foods. Every chosen food item was artificially contaminated with Staphylococcus aureus WDCM 00034. The SIR value obtained was 0.04 ≤ 2× 0.11 (the lowest mean of SR value from ISO 6888-1:2021) which indicated that the National Quality Control Laboratory of Drug and Food (NQCLDF), Indonesian FDA was able to implement the method very well. In addition, the eBias value for all types of food tested was below 0.5log10, which showed that the quantitative method for coagulase-positive Staphylococci (Staphylococcus aureus and other types) could be applied in the NQCLDF laboratory for the extensive scope of food.