RLRobin Litten

Robin Litten

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robin Litten has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dorsal bridge plating, volar plating, or both? A retrospective analysis of clinical and radiographic outcomes of intraarticular distal radius fracture fixation techniques

    by Robin Litten, Anthony Wilson, Matthew Yeager, Robert Rutz, Ryan McIlwain, Katie Frith, Jonathan Quade

    Purpose: Optimal fixation for complex AO/OTA 2R3C intraarticular distal radius fractures remains debated, particularly the role of dorsal bridge plating (DBP) alone or in combination with volar plating (VP). This study compared radiographic outcomes and complications across VP, DBP, and combined VP-DBP constructs. Methods: A retrospective cohort study was conducted at a single Level I trauma center (2020–2024). Adults with AO/OTA 2R3C distal radius fractures treated with VP alone, DBP alone, or combined VP-DBP and with ≥ 6 months of follow-up were included. Standard radiographic parameters (volar tilt [VT], radial height [RH], radial inclination [RI], and ulnar variance [UV]) were measured immediately postoperatively and at final follow-up. Wrist range of motion (flexion, extension, pronation, supination) at final follow-up was recorded from clinic documentation. Complications included fracture-related infection (FRI), reoperation to promote bone healing, hardware removal (HWR), and unplanned reoperation. Group comparisons used one-way ANOVA and chi-square/Fisher’s exact tests. Results: A total of 153 patients (mean age: 50 years) were included; 84 (54.9%) underwent VP, 44 (28.8%) DBP, and 25 (16.3%) combined fixation. Immediately postoperatively, DBP achieved greater RI (22.3° versus 19.7° VP versus 18.9° combined) and RH (13.4 mm versus 11.6 mm versus 11.3 mm), while VT was greatest with VP (9.9° versus 8.3° DBP versus 4.5° combined; all p < 0.05). At final follow-up, UV, VT, RI, and RH did not differ significantly between constructs, although all groups demonstrated increased UV over time, greatest in the combined cohort. FRI (0-3.6%) and unplanned reoperation (7.8% overall) rates were similar across groups. HWR was more frequent after DBP and combined fixation, reflecting planned implant removal. At final follow-up, VP demonstrated greater wrist flexion and extension compared with DBP and combined fixation ( p < 0.05), while pronation and supination were similar between groups. Conclusion: Across fixation strategies for intraarticular distal radius fractures, no single construct demonstrated radiographic superiority at final follow-up, although volar plating was associated with greater flexion and extension at final follow-up. These findings underscore the importance of tailoring fixation strategy to fracture pattern and patient-specific factors when managing complex distal radius fractures.

  • Open Access

    Early complications associated with fixation constructs of operatively treated patella fractures: a retrospective study

    by Robin Litten, Anthony Wilson, Doriann Alcaide, Ryan McIlwain, Swapnil Singh, Jonathan Ellis, Joey Johnson, Clay Spitler

    Purpose: Although multiple fixation constructs exist for patella fractures, postoperative complications are common, and optimal construct choice remains unclear. This study evaluated construct-specific complication rates in operatively treated patella fractures. Methods: A retrospective review was conducted of adult patients who underwent surgical fixation of patella fractures (AO/OTA 34) at a Level I trauma center between 2012 and 2022. Patients younger than 18 years, treated with isolated cerclage wiring, or with less than 90 days of follow-up were excluded. Patients were stratified by fixation construct: tension band wiring (TBW), plate, screws, tendon advancement, or multiple constructs. Demographic, injury, and clinical data were obtained from medical records. Primary outcomes included reoperation, fixation failure, nonunion, deep infection, and SIR. Results: A total of 242 patients were included and stratified by construct type: TBW ( n = 106), plate ( n = 18), screws ( n = 39), TA ( n = 60), and multiple constructs ( n = 19). Patients treated with plates were significantly younger (37.1 vs. 45.8 years; p = 0.023) and more likely to have open fractures (50.0%; p = 0.025), comminuted fracture patterns (≥ 4 fragments: 83.3%; p < 0.001), and OTA 34C3 fractures (77.8%; p < 0.001). Plate fixation was associated with a higher rate of SIR compared to other groups (27.8%; p = 0.012), while no significant differences were observed in reoperation ( p = 0.142), nonunion ( p = 0.652), fixation failure ( p = 0.316), or infection ( p = 0.505). In subgroup analysis, suture cerclage augmentation in TBW was associated with significantly higher rates of reoperation (85.7% vs. 19.2%; p < 0.001), nonunion (57.1% vs. 8.1%; p = 0.003), and fixation failure (57.1% vs. 15.2%; p = 0.019). Conclusion: Plate fixation was associated with higher SIR, and suture cerclage in TBW constructs was associated with increased complications in patella fracture fixation.


  • Open Access

    Factors influencing patient-reported outcomes in operatively managed tibial plateau fractures

    by Doriann Alcaide, Robin Litten, Jeffrey Clay Krout, Garrett Hawkins, Alexa Smitherman, Ryan McIlwain, Gerald McGwin, Clay Spitler, Joey Johnson

    Purpose: Tibial plateau fractures are complex injuries with high complication rates, yet their broader impact on patient-reported function and quality of life remains underexplored. This study assessed the impact of demographics, fracture patterns, and treatment characteristics on patient-reported outcomes measurement information system (PROMIS) scores in patients who underwent surgical fixation of tibial plateau fractures. Methods: A retrospective cohort study was conducted at a Level I trauma center (2022–2024) including adults with operatively treated tibial plateau fractures who completed 6-month PROMIS surveys. Exclusions were age < 18 years, non-operative or percutaneous fixation, and inadequate medical record documentation. Primary outcomes were 6-month scores for PROMIS physical function (PF), pain interference (PI), global physical health (GPH), global mental health (GMH), anxiety/depression, brief resilience scale (BRS), and percent of normal function. Outcomes were compared by sex, age, mechanism of injury, fracture pattern, Schatzker type, and external fixation. Results: Of 413 patients, 106 met inclusion criteria. Mean age was 50.4 years and 51.9% were male. Patients < 50 reported higher PI (62.7 vs. 59.3, p = 0.017) and lower GPH (38.8 vs. 42.4, p = 0.023). Among females, those < 50 had higher PI (64.0 vs. 58.5, p = 0.009), lower GPH (37.5 vs. 43.1, p = 0.011), and lower anxiety (60.2 vs. 64.1, p = 0.046). After adjustment, high-energy injuries were associated with worse GPH ( p = 0.014), GMH ( p = 0.011), depression ( p = 0.009), anxiety ( p = 0.015), percent of normal ( p = 0.002), and BRS ( p = 0.004). Conclusion: Early recovery after surgically treated tibial plateau fractures varies by patient and injury characteristics: younger patients, particularly females under 50, reported worse pain and global physical health, while high-energy mechanisms were independently associated with poorer physical and psychological outcomes across multiple domains.


  • Open Access

    Effect of complications and reoperations on PROMIS scores for tibial plateau fractures

    by Alexa A Smitherman, Robin M Litten, Garrett N Hawkins, Doriann M Alcaide, Ryan N McIlwain, Jeffrey Clay Krout, Clay A Spitler, Joey P Johnson

    Purpose: Tibial plateau fractures can result in significant morbidity, and complications following surgical fixation may negatively impact recovery. We aimed to evaluate whether such complications influence patient-reported outcomes at 6 months postoperatively. Methods: We conducted a retrospective cohort study at a single level I trauma center from 2022 to 2024. Adult patients who sustained a tibial plateau fracture (AO/OTA 41) treated with open reduction internal fixation (ORIF) were eligible for inclusion if they had completed Patient-Reported Outcomes Measurement Information System (PROMIS) surveys at 6 months postoperatively and had clinical follow-up confirming radiographic healing. Patients were excluded if they were under 18 years of age, lacked adequate medical record documentation, were managed non-operatively or with closed reduction percutaneous fixation, or did not complete PROMIS surveys at the 6-month time point. The primary outcomes were PROMIS scores assessing physical function (PF), pain interference (PI), global physical health (GPH), global mental health (GMH), anxiety, and depression. Secondary outcomes included percent of normal function and Brief Resilience Scale (BRS) scores. These outcomes were compared between patients who experienced complications and those who did not. Results: A total of 106 patients were included (mean age 50.4 years; mean follow-up 261.5 days). Complications occurred in 25.5% of patients, including fracture-related infection (FRI, 10.4%), DVT/PE (7.5%), and reoperation within 6 months (11.3%). Patients with FRI had significantly lower PROMIS-PF scores at 6 months compared to those without FRI (31.5 vs. 37.4, p = 0.015), exceeding the MCID. Other PROMIS domains were not significantly different. Patients undergoing early reoperation prior to 6 months, or reoperation to promote bone healing at any timepoint, demonstrated lower PF scores, though these differences were not statistically significant. Conclusion: In this cohort of patients with tibial plateau fractures, FRI was associated with significantly worse physical function at 6-months as measured by the PROMIS-PF score. This difference was also clinically significant, exceeding the MCID.


  • Open Access

    Technical note: novel utilization of an H-plate for the treatment of posterior wall components of acetabular fractures

    by Anjali Malhotra, Doriann Alcaide, Robin Litten, Nigel Blackwood, Jared Halstrom, Jonathan Ellis, Clay Spitler, Joey Johnson

    Posterior wall components of acetabular fractures are challenging injuries to treat due to the frequency of comminution, marginal impaction and high contact forces of the femoral head on the posterior wall. A variety of fixation techniques for these components have been utilized including conventional buttress plating and free screws. The objective of this report is to describe the technical application of the DePuy Synthes 2.7mm nonlocking hindfoot and midfoot plate, a 5-hole implant (the “H-plate”) (DePuy Synthes; Raynham, MA), in the surgical treatment of posterior wall fractures and to present early clinical outcomes from its use. We report a series of 95 patients who underwent fixation of posterior wall components of acetabular fractures (AO/OTA 62) with an H-plate construct. At a mean follow-up of 257 days, conversion to total hip arthroplasty occurred in six patients (6.3%), there were no postoperative dislocations, four surgical site infections (4.2%), and no cases required revision open reduction internal fixation. The H-plate’s overall shape may enhance stability due to its width and design, and these early results suggest that the H-plate may represent a viable option for stabilization of posterior wall fractures. Level of evidence: III.


  • Identifying risk factors for systemic complications following fracture-related infection

    by Robin M. Litten, Doriann M. Alcaide, Robert W. Rutz, Elizabeth M. Benson, Karen J. Carter, Evan G. Gross, Ryan N. McIlwain, Alex R. Heatherly, Matthew T. Yeager, Joshua T. Stripling, et al.

    Purpose Fracture-related infection (FRI) is a serious complication of orthopedic trauma that can result in systemic complications affecting multiple organ systems. While diagnostic criteria have become standardized, predictors of systemic complications remain poorly understood. This study aimed to evaluate factors associated with the development of systemic complications following operative FRI management. Methods We conducted a retrospective cohort study at a single Level I trauma center from 2013 to 2021. Adult patients with postoperative FRI requiring hospitalization and surgical treatment were included. Patients required either six months of follow-up or development of a systemic complication before that point. Systemic complications included cerebrovascular accident (CVA), myocardial infarction (MI), acute respiratory distress syndrome (ARDS), deep vein thrombosis/pulmonary embolism (DVT/PE), acute kidney injury (AKI), sepsis, and mortality. Demographics, comorbidities, injury characteristics, lab values, and operative details were compared between patients with and without complications. Results A total of 281 patients with FRI were included, with 70 (24.9%) experiencing systemic complications. The mean age of patients with complications was significantly higher (51.7 years) compared to those without (43.8 years, p < 0.001). Systemic complications included sepsis (11.7%), AKI (8.2%), DVT/PE (5.0%), and mortality (2.5%). Patients with complications had higher body mass index (BMI) (31.6 kg/m2 vs. 29.5 kg/m2, p = 0.054), a greater prevalence of diabetes (30.0% vs. 16.1%, p = 0.011), cardiovascular disease (CVD) (42.9% vs. 23.2%, p = 0.002), chronic obstructive pulmonary disease (COPD) (20.0% vs. 4.7%, p < 0.001), prior CVA (11.4% vs. 1.4%, p < 0.001), chronic kidney disease (CKD) (18.6% vs. 3.3%, p < 0.001), and higher Charlson Comorbidity Index (CCI) (2.2 vs. 1.0, p < 0.001). No significant differences were observed in fracture characteristics, operative details, or preoperative laboratory values (white blood cell [WBC] count, erythrocyte sedimentation rate [ESR], C-reactive protein [CRP], albumin, prealbumin) between the groups. Multivariate analysis identified higher CCI as an independent risk factor for systemic complications (OR 1.83, 95% CI 1.31–2.57; p = 0.001). Conclusion Patient characteristics such as age, diabetes, CVD, COPD, CVA, CKD, and CCI differed significantly in patients with FRI who experienced systemic complications from those without. CCI was an independent risk factor for systemic complications following FRI. Level of Evidence Patient characteristics such as age, diabetes, CVD, COPD, CVA, CKD, and CCI differed significantly in patients with FRI who experienced systemic complications from those without. CCI was an independent risk factor for systemic complications following FRI. III.


  • Open Access

    Retrospective Evaluation of Pelvic and Acetabular Fracture Fixation Using the Stryker PRO Pelvis Next Generation Plating System

    by Robin M. Litten, Doriann M. Alcaide, Ryan N. McIlwain, Clay A Spitler, Joseph P. Johnson

    Introduction Acetabular and pelvic fractures account for roughly 3% of all skeletal injuries and typically result from high-energy trauma. Surgical fixation is often required to restore pelvic stability and joint congruency. These procedures are technically demanding due to complex pelvic anatomy and limited access. Reconstruction plates are commonly used for their versatility in compression, tension, buttress, and antiglide functions. The Stryker Pelvic PRO Next Generation plating system (Stryker, Portage, MI) offers implants for anterior and posterior fixation, designed to accommodate complex bony morphology. This study evaluates clinical and radiographic outcomes in patients treated with this implant system. We hypothesized that its use would yield rates of bone consolidation, nonunion, and adverse events comparable to the current literature. Methods With institutional review board approval, a retrospective review was conducted at a level I trauma center for patients treated with the Stryker PRO system between January and October 2024. Cases were identified using Current Procedural Terminology codes 27226, 27227, and 27228. Demographics, injury characteristics, surgical details, and outcomes were collected. Radiographic bone consolidation was defined as the presence of bridging callus in three out of four cortices with no visible fracture line or the disappearance of fracture lines, while clinical consolidation was defined as the patient achieving full weight-bearing status without pain. Delayed union was defined as the absence of radiographic healing by three months post-operatively, while nonunion was defined as persistent fracture at six months requiring surgical intervention or documented pain with visible fracture line. Descriptive statistics were performed using IBM SPSS Version 29.0.2.0. Results The study included 20 patients (mean age 44.6, 70% male) with pelvic or acetabular fractures. Most injuries resulted from motor vehicle accidents (70%), with common fracture types including AO 62.A1/62.B1 and posterior wall fractures. Radiographic and clinical consolidation were achieved in 80% of cases each, with 95% overall union. Seven adverse events occurred in five (25%) patients, including infection, heterotopic ossification, osteolysis, and avascular necrosis; 16.6% required reoperation. A total of 28 plates were used, most commonly spring plates (50%); 70% of patients required additional fixation. Conclusion The Stryker PRO implant system demonstrated rates of bone consolidation, nonunion, and adverse events comparable to the current literature.