MTMarco Torrente

Marco Torrente

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marco Torrente has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative evaluation of 2D RGB and 3D RGB-D imaging for non-contact biomass estimation in lettuce

    by Marco Torrente, Paola Pasta, Paolo Tirelli, Aldo Calcante, Roberto Oberti

    Crop phenotyping refers to the systematic measurements of plant traits, including morphological and structural characteristics, such as plant size, leaf area, flower density, biomass growth, in response to environmental conditions, biotic and abiotic stress, and management treatments. Phenotyping is crucial in modern agriculture for developing improved crop varieties, increasing yield and resource-use efficiency. Traditional phenotyping approaches are highly labour-intensive and time-consuming, especially under field conditions, where manual measurements are difficult and often prone to inconsistencies and inaccuracies. Over the last decades, advances in imaging and sensor technology have progressively shifted research toward non-destructive, high-throughput phenotyping methods, with three-dimensional (3D) imaging recently emerging as a particularly promising tool.In this study, a traditional two-dimensional (2D) RGB imaging workflow was compared with a 3D RGB-D imaging approach, based on a low-cost Microsoft Kinect v2 sensor, for non-contact biomass estimation of lettuce plants measured from a top-view configuration.The objective was to assess whether 3D volumetric descriptors extracted from point-cloud data can provide better estimation accuracy and robustness than conventional 2D projected canopy area, particularly across different growth stages and canopy architectures. This evaluation is essential for developing reliable, low-cost, and scalable phenotyping solutions suitable for greenhouse automation, high-throughput cultivar screening, and digital field monitoring platforms.The 3D approach involved the development and evaluation of two algorithms. The first algorithm performs voxelization of the point cloud corresponding to each individual plant, while the second builds upon this step by incorporating a reconstruction technique to account for plant structures occluded from the top-view perspective, thereby expected to further enhancing the accuracy of biomass estimation. The 2D RGB-based method achieved an R2 of 0.88 (RMSE = 0.27 g; MAPE = 18.3%) in estimating the plant biomass, as determined by destructive harvesting and leaves dry matter weight. In contrast, the 3D approach significantly improved prediction accuracy, reaching an R2 of 0.94 (RMSE = 0.21 g; MAPE = 16.1%) with the voxelization method alone, and an R2 of 0.98 (RMSE = 0.11 g; MAPE = 11.6%) when combined with the reconstruction algorithm. These results demonstrate the superior robustness and reliability of low-cost 3D imaging system for biomass estimation, and highlight the critical role of the dedicated volumetric reconstruction algorithm proposed in this study. The findings confirm that, in addition to advanced sensing technologies, the design of tailored and high-performing algorithms is essential for accurate and reliable biomass assessments, supporting low-cost solutions for precision agriculture and plant breeding applications.

  • Open Access

    Cost-effective IoT hyperspectral prototype for distributed agri-food product monitoring

    by Sara Vignati, Alessio Tugnolo, Marco Torrente, Alessia Pampuri, Riccardo Guidetti, Roberto Beghi, Valentina Giovenzana

    Hyperspectral imaging (HSI) is a non-destructive technique that is employed to assess quality parameters and integrate monitoring across the supply chain in the context of Industry 4.0. Although promising, HSI faces challenges such as high cost and equipment requirements. However, advances in technology and 3D printing are enabling low-cost solutions that still need to be validated in the field. This work presents the development of a low-cost hyperspectral prototype, built using 3D elements and commercially available electronic components, and operating in the spectral range from 400 nm to 1000 nm. Furthermore, two types of gratings have been compared. In the first part of the study, the calibration process using RGB LEDs and a halogen lamp is described in detail. The second part of the study presents the results of a few applications on a food matrix under controlled light conditions, which were conducted to evaluate the performance of the prototype. The extracted spectra were normalised and subsequently pre-processed with either SNV (Standard Normal Variate) transform or the Savitzky–Golay (SG) derivative. Finally, the data were explored with PCA (Principal Component Analysis), which confirmed the ability of the prototype to distinguish samples of different colours (first trial), assess the decay of different apple samples (second trial) and differentiate between healthy and damaged tissues (third trial). The experimental results were consistent with the anticipated outcomes, and both types of grating demonstrated favourable performance.