Jin Ho Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jin Ho Cho has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dong Ho Shin
Institute of Biomedical Engineering Research, Kyungpook National University, Daegu, 41944, Korea
1 shared publication - Jyung Hyun Lee
Department of Biomedical Engineering, School of Medicine, Kyungpook National University, 680 Gukchaebosang-ro, Jung-gu, Daegu 41944, Republic of Korea
1 shared publication - Ki Woong Seong
Department of Biomedical Engineering, Kyungpook National University Hospital, 130 Dongdeok-ro, Jung-gu, Daegu 41944, Republic of Korea
1 shared publication - Myoung Nam Kim
Department of Biomedical Engineering, School of Medicine, Kyungpook National University, 680 Gukchaebosang-ro, Jung-gu, Daegu 41944, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 19 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5679
Implementation of a Parametric Ultrasonic Receiver Using Multilayer Lead Zirconate Titanate for a Feasibility Study of an Ultrasonic-Beam-Focused Hearing Aid
We demonstrated that focusing an ultrasonic beam on the eardrum can overcome the high-frequency sensitivity limitations and acoustic distortion of conventional hearing aid receivers. Multilayer PZT was used for an ultrasonic receiver that operates at low voltage and enters the external auditory canal, and a 3 mm radius radiator was designed to radiate the focused parametric acoustic signal to the center of the eardrum based on an acoustic analysis according to the frequency. To this end, an ultrasonic earphone consisting of a radiator attached to multilayer PZT and a 130 kHz parametric ultrasonic modulator was implemented; vibration and sound pressure were measured using a laser vibrometer and a tube-type microphone. The proposed parametric ultrasonic receiver generates an average sound pressure of 70 dB SPL at a frequency of 1~10 kHz with a 10 Vpeak applied voltage; this was implemented to provide a higher output in the range of 5 kHz and above, which is difficult to cover with existing receivers.
- 19 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5679
Open AccessImplementation of a Parametric Ultrasonic Receiver Using Multilayer Lead Zirconate Titanate for a Feasibility Study of an Ultrasonic-Beam-Focused Hearing Aid
We demonstrated that focusing an ultrasonic beam on the eardrum can overcome the high-frequency sensitivity limitations and acoustic distortion of conventional hearing aid receivers. Multilayer PZT was used for an ultrasonic receiver that operates at low voltage and enters the external auditory canal, and a 3 mm radius radiator was designed to radiate the focused parametric acoustic signal to the center of the eardrum based on an acoustic analysis according to the frequency. To this end, an ultrasonic earphone consisting of a radiator attached to multilayer PZT and a 130 kHz parametric ultrasonic modulator was implemented; vibration and sound pressure were measured using a laser vibrometer and a tube-type microphone. The proposed parametric ultrasonic receiver generates an average sound pressure of 70 dB SPL at a frequency of 1~10 kHz with a 10 Vpeak applied voltage; this was implemented to provide a higher output in the range of 5 kHz and above, which is difficult to cover with existing receivers.