VRViktoria Rubel

Viktoria Rubel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Viktoria Rubel has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of the dependence of the filtration properties of a biopolymer system on pressure, temperature and concentration of components

    by Viktoria Rubel, Roman Slichenko

    The object of study is the biopolymer system “X”, which is used as a clay-free drilling fluid for development of productive horizons. Biopolymer system “X” is a clay-free drilling fluid for drilling directional and horizontal wells, development of productive horizons under high pressures and temperatures. A distinctive feature of the biopolymer system is a high level of mineralization, increased heat resistance and high density, which significantly expands the scope of clay-free muds. At the same time, this system has a number of significant advantages: – high level of mineralization; – increased heat resistance (operable up to 150 °C); – high density, which expands the scope of application; – provides a higher coefficient of recovery of reservoir permeability compared to traditional weighted solutions; – low content of colloidal particles, which reduces the risk of deterioration of reservoir performance; – ability to control filtration properties at high temperatures and pressures. The following disadvantages can be identified based on the research: Significant increase in the filtration rate with increasing temperature (nonlinear dependence with a correlation coefficient of 0.773). 2. The need to maintain a constant concentration of potassium chloride (~3 %) to ensure the development quality of productive formations. Difficulty in controlling the properties due to the need to accurately select the concentrations of various components (sodium chloride and organomineral colmatant). The optimal ratio of components to ensure the stability of the system at temperatures up to 150 °C was obtained: sodium chloride concentration 15–20 %, stabilizer 0.75–1 %. This is due to the fact that the proposed composition has a number of features of synergistic interaction of the components, in particular the formation of stable complexes between biopolymers and sodium ions, which prevents the thermal destruction of polymer chains at high temperatures. At the same time, the stabilizer forms an additional protective layer around the polymer molecules, ensuring their resistance to oxidation and hydrolysis under high pressure of up to 7 MPa. The obtained research results indicate the possibility of effective use of the biopolymer system at high temperatures and pressures due to the thermostabilizing effect of sodium chloride and organo-mineral colmatant.

  • Open Access

    Selection of the optimal formulation of the biopolymer system for the stimulation of productive formations

    by Viktoria Rubel, Roman Slichenko

    The object of study in this paper is the biopolymer system «X» – a complex composition that includes a biopolymer, salts and a thermal stabiliser intended for use in drilling fluids at high temperatures. The components of the formulation include complex reagent «X» for regulating structural, mechanical, rheological and filtration properties, as well as inhibitors (sodium and potassium chloride) and filler. Components of the biopolymer system (sodium chloride, organo-mineral colmatant thermal stabiliser) increase its thermal stability. One of the most problematic areas is the mechanism of sodium chloride's thermal stabilising effect. It is associated with an increase in the overall mineralisation of the drilling mud, which leads to a certain conformation of biopolymer molecules, accelerates gelation processes and counteracts the temperature dilution of the system. The results obtained can be explained as follows: – an increase in the concentration of sodium chloride leads to an increase in the ionic strength of the solution, which contributes to a change in the conformation of biopolymer molecules, enhancing intermolecular interactions and, as a result, increasing the viscosity and stability of the system; – the organo-mineral colmatant heat stabiliser promotes the formation of a filtration crust on the well walls, which prevents fluid loss and reduces rock permeability; – all components of the system interact with each other, affecting the properties of the solution. The optimum ratio of components allows achieving the required rheological characteristics and ensuring the stability of the system at high temperatures. As a result of processing the information on technologies for tapping productive horizons, the disadvantages and advantages of each of them were noted. The existing drilling fluid systems used to tap productive horizons at high temperatures were considered. However, more attention was paid to the selection of a new optimal formulation of the biopolymer system, in accordance with the specified rheological and structural and mechanical properties for further implementation in practice. This ensures the possibility of obtaining predictive parameters of the drilling mud. The proposed system has a number of advantages over similar ones, namely: – the system retains its properties at high temperatures; – the system provides the required values of viscosity, filtration and static shear stress; – due to the use of an optimal formulation, high efficiency is achieved at a relatively low cost.


  • Open Access

    Development of a mathematical model of the operation of the swab generator valve

    by Viktoria Rubel, Vyacheslav Rubel, Jan Ziaja, Roman Yaremiychuk

    The object of research in the work is a mathematical model of the operation of a hydrodynamic well generator of the spring-valve type. The existing problem lies in the fact that vibrating wave swabbing differs from known methods of vibrating wave influence on the near-breakout zone of the formation in its ease of execution and, as a result, a much smaller range of equipment. At the same time, its effectiveness should not be inferior to known methods because the treatment of the formation is carried out by elastic low-frequency pressure fluctuations against the background of depression on the formation. Since the swab generator valve is, in fact, a hydrodynamic well generator (HWG) of the spring-valve type, the processes of pressure fluctuations in the considered devices will be similar. However, because of the review of HWG designs, the presence of a mathematical model describing the operation of rotor-type devices, and not valve type, was revealed. Despite the fact that the mathematical model takes into account all the main factors that determine the process of the HWG piston movement, this model cannot be used to describe the operation process of the swab generator valve. Due to the absence of a pulsating flow created at the wellhead by pumping units. Taking this fact into account, as well as taking into account the compressibility of the liquid passing through the valve, a new mathematical model was developed. It describes both the process of operation of a spring-valve type HWG operating in a well on pump-compressor pipes, and the operation of a swab generator valve that is lowered into a well on a rope. Thanks to this, it is possible to obtain the parameters of the oscillating system: geometric dimensions, inertial mass of moving parts, stiffness of the spring, coefficient of viscous friction between the piston and the valve body, as well as parameters of the working fluid: pressure, flow and its rheological properties. In comparison with the similarly known technology of vibration wave impact on a formation with known HWG, it provides such advantages as a higher speed of movement and frequency of oscillations of the moving end of the spring from the identified essential parameters of the oscillating system and the working fluid of the spring (100–1000 N/mm), consumption of working liquid (10–130 m3/h), valve opening pressure (1–7 MPa). This will make it possible to calculate a helical cylindrical compression spring made of round steel for its operation in the valve of the swab generator without collision of turns.