ŁKŁukasz Kołodziej

Łukasz Kołodziej

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Łukasz Kołodziej has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Temporal–Spatial Parameters of Gait After Total Knee Arthroplasty

    by Karina Szczypiór-Piasecka, Paulina Adamczewska, Łukasz Kołodziej, Paweł Ziętek

    Background/Objectives: Gait abnormalities in advanced knee osteoarthritis (KOA) are characterized by decreased stride length, walking speed, and cadence. Total knee arthroplasty (TKA) is intended to improve temporal–spatial gait parameters; however, the extent and timing of functional recovery remain under investigation. To assess changes in stride length, walking speed, and cadence following TKA in short- and long-term perspectives, and to compare outcomes with a non-operated KOA cohort. Methods: A prospective observational study was conducted involving 46 patients with unilateral KOA (grades III–IV, Kellgren–Lawrence scale) who underwent cemented TKA via a medial parapatellar approach. Group I (n = 34) was assessed one day prior to surgery and six weeks postoperatively. Group II (n = 12), a follow-up subset, was reassessed 1.5 years postoperatively. Group III (n = 34) served as a non-operated control group, assessed only preoperatively. Temporal–spatial gait parameters were evaluated under standardized conditions using a two-dimensional video analysis (Kinovea® software version 0.8.27). Stride length (m) and walking speed (m/s) were assessed during continuous walking along a 15 m corridor, with at least three valid gait cycles averaged per trial. Cadence (steps/min) was determined during a one-minute walk and verified frame-by-frame. No structured outpatient physiotherapy was provided; all patients followed a standardized in-hospital rehabilitation protocol. Results: In Group I, the mean stride length increased from 0.40 ± 0.10 m to 0.42 ± 0.10 m (p = 0.247), walking speed improved from 0.41 ± 0.027 m/s to 0.47 ± 0.022 m/s (p = 0.063), and cadence increased significantly from 72.9 ± 7.8 to 77.1 ± 8.6 steps/min (p = 0.044). In Group II, the mean stride length rose from 0.39 ± 0.10 m to 0.52 ± 0.09 m (p < 0.001), walking speed improved from 0.44 ± 0.02 m/s to 0.69 ± 0.01 m/s (p < 0.001), and cadence increased from 73.7 ± 8.8 to 103.6 ± 7.4 steps/min (p < 0.001). Compared to the control group (Group III: stride length 0.42 ± 0.09 m; walking speed 0.41 ± 0.02 m/s; cadence 73.9 ± 7.9 steps/min), Group II demonstrated superior values across all parameters (p < 0.001 for each comparison). No significant correlations were observed between BMI and gait outcomes. Conclusions: Total knee arthroplasty resulted in progressive improvement in temporal–spatial gait parameters. While early postoperative gains were limited, substantial functional restoration was observed at long-term follow-up, emphasizing the importance of extended recovery monitoring in post-TKA evaluation.


  • Open Access

    The Temporal-Spatial Parameters of Gait After Total Knee Arthroplasty

    by Karina Szczypiór-Piasecka, Paulina Adamczewska, Łukasz Kołodziej, Paweł Ziętek

    Introduction: Antalgic gait is characteristic for knee osteoarthritis. It is marked by a shortened swing phase and an extended stance phase, significantly deviating from biomechanical norms and resulting in a reduced step length. We hypothesized that total knee arthroplasty (TKA) would improve the temporal-spatial parameters of gait. Therefore, stride length, walking speed, and the relationship between gait performance changes and selected demographic features of the study group were measured, compared, and analyzed. Material and Methods: A total of 46 consecutive patients (24 women and 22 men) with unilateral knee osteoarthritis who underwent surgical treatment were enrolled in this prospective study. Group I (n=34) was assessed one day before surgery and again six weeks postoperatively. Group II (n=12) was evaluated preoperatively and 1.5 years after surgery. The study included three stages. In the first stage, patients were assigned to their respective groups based on the planned follow-up period. In the second stage, preoperative assessments of step length (m), walking speed (m/s), and cadence (steps/min) were conducted. In the third stage, selected gait parameters were reassessed: six weeks postoperatively in Group I and 1.5 years postoperatively in Group II. During the evaluation of step length and walking speed, gait was digitally recorded to ensure measurement precision. Cadence was assessed during a one-minute walk test. Throughout the study, patients walked naturally, in a manner reflecting their everyday locomotion. Results: In Group I, the mean step length slightly increased from 0.40 m (Min 0.175; Max 0.60) before surgery to 0.42 m (Min 0.21; Max 0.75) postoperatively. The stride length increased by 0.02 m, but this change was not statistically significant. The mean walking speed rose significantly from 0.41 m/s (Min 0.20; Max 0.88) preoperatively to 0.47 m/s (Min 0.23; Max 1.20) six weeks after surgery. Cadence showed a statistically significant increase from 72.9 steps/min (Min 60; Max 92) to 77.06 steps/min (Min 64; Max 92) (p = 0.044). In Group II, the average step length rose significantly from 0.39 m (Min 0.27; Max 0.60) before surgery to 0.52 m (Min 0.42; Max 0.68) at the 1.5-year follow-up. Walking speed also increased significantly from 0.44 m/s (Min 0.29; Max 0.82) preoperatively to 0.69 m/s (Min 0.44; Max 1.46) postoperatively. Cadence significantly improved from a mean of 73.7 steps/min (Min 60; Max 92) to 103.6 steps/min (Min 87; Max 121) at the final follow-up. Statistical analysis revealed a highly significant difference between preoperative and 1.5-year postoperative measurements all p values < 0.001. Conclusion: Total knee arthroplasty improves the temporal-spatial parameters of gait, measured by stride length and walking speed, both six weeks and 1.5 years after surgery.