Carlos Spagnuolo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos Spagnuolo has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Glaeser
Cardiovascular Research Institute Basel (CRIB) and Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland; GREAT Network, Rome, Italy
5 shared publications - Paolo Bima
Department of Medical Sciences, University of Turin , Turin
5 shared publications - Christian Mueller
University Hospital Basel, University of Basel
4 shared publications Michael Christ
Emergency Department, Kantonsspital Luzern, Lucerne, Switzerland
4 shared publicationsArnold von Eckardstein
3 shared publicationsBeata Morawiec
GREAT Network, Roma, Italy; Second Department of Cardiology, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Katowice, Katowice, Poland
3 shared publications
Latest Publications
- Open Access
- 21 April 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (8) , e045517
Alternative Rule‐Out Cutoffs for a Novel High‐Sensitivity Cardiac Troponin I Assay in Patients With Suspected Myocardial Infarction
Background: There is major uncertainty among physicians on how to best use the novel hs‐cTnI (high sensitivity‐cardiac troponin I)‐VITROS assay, as the limit of quantification (2 ng/L), applied by the US Food and Drug Administration and other regulators, is higher than the limit of detection (1 ng/L)‐based rule‐out cutoffs from recent pilot studies for 0/1‐hour and 0/2‐hour algorithms. Methods: This prospective, multicenter study aimed to derive and validate higher limit of quantification‐based assay‐specific cutoffs for safe and efficient rule‐out of myocardial infarction among adult patients presenting with acute chest discomfort to the emergency department. Final diagnoses of myocardial infarction were centrally adjudicated by 2 independent cardiologists, blinded to hs‐cTnI‐VITROS concentrations. Results: Among 2931 eligible patients, 467 (16%) were diagnosed with myocardial infarction. In the derivation cohort (n=1466), a cutoff ≤2 ng/L at presentation in patients with chest pain onset >3 hours (direct rule‐out) and ≤2 ng/L in combination with a 1‐hour absolute change of ≤1 ng/L ruled out 51% of patients, with a sensitivity of 99.1% (96.9%–99.8%). Predefined rule‐in thresholds (0 hour‐value ≥40 ng/L [direct rule‐in] or an absolute change within 1 hour of ≥4 ng/L) identified 16.9% of patients, with a specificity of 95.9% (94.7%–96.9%). Very high sensitivity and specificity were confirmed in the validation cohort (n=1465). Comparable findings were observed for the alternative 0/2‐hour algorithm with ≤2 ng/L as the rule‐out threshold. Conclusions: The alternative 0/1‐hour and 0/2‐hour algorithms using limit of quantification‐based rule‐out cutoffs of ≤2 ng/L with the hs‐cTnI‐VITROS assay demonstrated very high safety and efficacy in suspected myocardial infarction. Registration: URL: https://www.clinicaltrials.gov/ ; Identifier: NCT00470587.
- 21 April 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (8) , e045517
Open AccessAlternative Rule‐Out Cutoffs for a Novel High‐Sensitivity Cardiac Troponin I Assay in Patients With Suspected Myocardial Infarction
Background: There is major uncertainty among physicians on how to best use the novel hs‐cTnI (high sensitivity‐cardiac troponin I)‐VITROS assay, as the limit of quantification (2 ng/L), applied by the US Food and Drug Administration and other regulators, is higher than the limit of detection (1 ng/L)‐based rule‐out cutoffs from recent pilot studies for 0/1‐hour and 0/2‐hour algorithms. Methods: This prospective, multicenter study aimed to derive and validate higher limit of quantification‐based assay‐specific cutoffs for safe and efficient rule‐out of myocardial infarction among adult patients presenting with acute chest discomfort to the emergency department. Final diagnoses of myocardial infarction were centrally adjudicated by 2 independent cardiologists, blinded to hs‐cTnI‐VITROS concentrations. Results: Among 2931 eligible patients, 467 (16%) were diagnosed with myocardial infarction. In the derivation cohort (n=1466), a cutoff ≤2 ng/L at presentation in patients with chest pain onset >3 hours (direct rule‐out) and ≤2 ng/L in combination with a 1‐hour absolute change of ≤1 ng/L ruled out 51% of patients, with a sensitivity of 99.1% (96.9%–99.8%). Predefined rule‐in thresholds (0 hour‐value ≥40 ng/L [direct rule‐in] or an absolute change within 1 hour of ≥4 ng/L) identified 16.9% of patients, with a specificity of 95.9% (94.7%–96.9%). Very high sensitivity and specificity were confirmed in the validation cohort (n=1465). Comparable findings were observed for the alternative 0/2‐hour algorithm with ≤2 ng/L as the rule‐out threshold. Conclusions: The alternative 0/1‐hour and 0/2‐hour algorithms using limit of quantification‐based rule‐out cutoffs of ≤2 ng/L with the hs‐cTnI‐VITROS assay demonstrated very high safety and efficacy in suspected myocardial infarction. Registration: URL: https://www.clinicaltrials.gov/ ; Identifier: NCT00470587.
- Top Cited PapersOpen Access
High-Sensitivity Cardiac Troponin T-gen6 Assay in Suspected Myocardial Infarction
Top Cited PapersOpen AccessHigh-Sensitivity Cardiac Troponin T-gen6 Assay in Suspected Myocardial Infarction
- Open Access
- 20 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (10) , e040468
Possible Misdiagnosis of Myocardial Infarction Using Regulatory‐Approved and Close‐to‐Bioequivalent Upper Limits of Normal for Cardiac Troponin
Background: Possible misdiagnosis of acute myocardial infarction (AMI) may occur due to inappropriate upper limit of normal (ULN) for cardiac troponin and has the potential to harm patients. In this observational international multicenter study, we aimed to assess to what extent the novel hs‐cTn‐assays are affected. Methods: A total of 6646 patients presenting with suspected AMI to the emergency department were enrolled. All level pairs (n=18 732) of 4 widely used high‐sensitivity cardiac troponin T/I (hs‐cTnT/I) assays using (1) the regulatory‐approved uniform and sex‐specific clinical ULN and (2) mathematically derived close‐to‐bioequivalent ULNs were assessed. The primary outcome was the quantification of the incidence of inconsistencies in the diagnosis of AMI. Inconsistency was defined as hs‐cTnT/I concentration above the recommended ULN in one but not the other assay: for example, hs‐cTnT–Elecsys+/hs‐cTnI–Architect– or hs‐cTnT–Elecsys−/hs‐cTnI–Architect+. Results: AMI was the adjudicated diagnosis in 1422 patients (21.4%). When the regulatory‐approved uniform ULN was used, the rate of inconsistent AMI diagnoses was 17.6% (Elecsys/Architect), 18.8% (Elecsys/Centaur), 14.2% (Elecsys/Access), 4.9% (Architect/Centaur), 8.3% (Architect/Access), and 7.4% (Access/Centaur), respectively. Overall, diagnostic mismatches were not decreased, but in fact increased using regulatory‐approved sex‐specific ULNs. In women as compared with men, they were 23.8% versus 17.6% (Elecsys/Architect), 30.1% versus 19.1% (Elecsys/Centaur), 23.2% versus 15% (Elecsys/Access), 7.2% versus 4.5% (Architect/Centaur), 8.3% versus 8.7% (Architect/Access) and 7.8% versus 8.2% (Access/Centaur), respectively. Using close‐to‐bioequivalent ULNs reduced inconsistencies by 15% to 20% ( P <0.001). Findings were confirmed in a sensitivity analysis among all level pairs with final diagnosis of AMI (mismatches in 7.3%–20.5%). Conclusions: Current regulatory‐approved uniform and sex‐specific ULNs for hs‐cTnT/I result in discordances in binary assay results, possibly impacting the diagnosis of AMI. A regulatory process that defines bioequivalent ULNs could reduce inconsistencies significantly. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT00470587.
- 20 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (10) , e040468
Open AccessPossible Misdiagnosis of Myocardial Infarction Using Regulatory‐Approved and Close‐to‐Bioequivalent Upper Limits of Normal for Cardiac Troponin
Background: Possible misdiagnosis of acute myocardial infarction (AMI) may occur due to inappropriate upper limit of normal (ULN) for cardiac troponin and has the potential to harm patients. In this observational international multicenter study, we aimed to assess to what extent the novel hs‐cTn‐assays are affected. Methods: A total of 6646 patients presenting with suspected AMI to the emergency department were enrolled. All level pairs (n=18 732) of 4 widely used high‐sensitivity cardiac troponin T/I (hs‐cTnT/I) assays using (1) the regulatory‐approved uniform and sex‐specific clinical ULN and (2) mathematically derived close‐to‐bioequivalent ULNs were assessed. The primary outcome was the quantification of the incidence of inconsistencies in the diagnosis of AMI. Inconsistency was defined as hs‐cTnT/I concentration above the recommended ULN in one but not the other assay: for example, hs‐cTnT–Elecsys+/hs‐cTnI–Architect– or hs‐cTnT–Elecsys−/hs‐cTnI–Architect+. Results: AMI was the adjudicated diagnosis in 1422 patients (21.4%). When the regulatory‐approved uniform ULN was used, the rate of inconsistent AMI diagnoses was 17.6% (Elecsys/Architect), 18.8% (Elecsys/Centaur), 14.2% (Elecsys/Access), 4.9% (Architect/Centaur), 8.3% (Architect/Access), and 7.4% (Access/Centaur), respectively. Overall, diagnostic mismatches were not decreased, but in fact increased using regulatory‐approved sex‐specific ULNs. In women as compared with men, they were 23.8% versus 17.6% (Elecsys/Architect), 30.1% versus 19.1% (Elecsys/Centaur), 23.2% versus 15% (Elecsys/Access), 7.2% versus 4.5% (Architect/Centaur), 8.3% versus 8.7% (Architect/Access) and 7.8% versus 8.2% (Access/Centaur), respectively. Using close‐to‐bioequivalent ULNs reduced inconsistencies by 15% to 20% ( P <0.001). Findings were confirmed in a sensitivity analysis among all level pairs with final diagnosis of AMI (mismatches in 7.3%–20.5%). Conclusions: Current regulatory‐approved uniform and sex‐specific ULNs for hs‐cTnT/I result in discordances in binary assay results, possibly impacting the diagnosis of AMI. A regulatory process that defines bioequivalent ULNs could reduce inconsistencies significantly. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT00470587.