Vikas Dhull
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vikas Dhull has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Vikas Hooda
Centre for Biotechnology, Maharshi Dayanand University, Rohtak 124001, India
3 shared publications Anjum Gahlaut
Centre for Biotechnology, Maharshi Dayanand University, Rohtak 124001, India
1 shared publicationAshish Gothwal
Centre for Biotechnology, Maharshi Dayanand University, Rohtak 124001, India
1 shared publicationKusum Lata
Centre for Biotechnology, Maharshi Dayanand University, Rohtak, Haryana 124001, India
1 shared publicationNeeraj Dilbaghi
Department of Bio & Nanotechnology, Guru Jambeshwar University of Science & Technology, Hisar 125001, India
1 shared publicationPuneet Beniwal
Centre for Biotechnology, Maharshi Dayanand University, Rohtak 124001, India
1 shared publication
Latest Publications
- Open Access
- 18 January 2016
- Published by Wiley in Biochemistry Research International
- Vol. 2016, 1-11
Fabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
The developed method used three enzymes comprised of cholesterol esterase, cholesterol oxidase, and peroxidase for fabrication of amperometric biosensor in order to determine total cholesterol in serum samples. Gold nanoparticles (AuNPs) and carboxylated multiwall carbon nanotubes (cMWCNTs) were used to design core of working electrode, having covalently immobilized ChO, ChE, and HRP. Polyacrylamide layer was finally coated on working electrode in order to prevent enzyme leaching. Chemically synthesised Au nanoparticles were subjected to transmission electron microscopy (TEM) for analysing the shape and size of the particles. Working electrode was subjected to FTIR and XRD. The combined action of AuNP and c-MWCNT showed enhancement in electrocatalytic activity at a very low potential of 0.27 V. The pH 7, temperature 40°C, and response time of 20 seconds, respectively, were observed. The biosensor shows a broad linear range from 0.5 mg/dL to 250 mg/dL (0.01 mM–5.83 mM) with minimum detection limit being 0.5 mg/dL (0.01 mM). The biosensor showed reusability of more than 45 times and was stable for 60 days. The biosensor was successfully tested for determining total cholesterol in serum samples amperometrically with no significant interference by serum components.
- 18 January 2016
- Published by Wiley in Biochemistry Research International
- Vol. 2016, 1-11
Open AccessFabrication and Optimization of ChE/ChO/HRP-AuNPs/c-MWCNTs Based Silver Electrode for Determining Total Cholesterol in Serum
The developed method used three enzymes comprised of cholesterol esterase, cholesterol oxidase, and peroxidase for fabrication of amperometric biosensor in order to determine total cholesterol in serum samples. Gold nanoparticles (AuNPs) and carboxylated multiwall carbon nanotubes (cMWCNTs) were used to design core of working electrode, having covalently immobilized ChO, ChE, and HRP. Polyacrylamide layer was finally coated on working electrode in order to prevent enzyme leaching. Chemically synthesised Au nanoparticles were subjected to transmission electron microscopy (TEM) for analysing the shape and size of the particles. Working electrode was subjected to FTIR and XRD. The combined action of AuNP and c-MWCNT showed enhancement in electrocatalytic activity at a very low potential of 0.27 V. The pH 7, temperature 40°C, and response time of 20 seconds, respectively, were observed. The biosensor shows a broad linear range from 0.5 mg/dL to 250 mg/dL (0.01 mM–5.83 mM) with minimum detection limit being 0.5 mg/dL (0.01 mM). The biosensor showed reusability of more than 45 times and was stable for 60 days. The biosensor was successfully tested for determining total cholesterol in serum samples amperometrically with no significant interference by serum components.
- Open Access
- 24 December 2014
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2014, 1-8
Preparation of Electrochemical Biosensor for Detection of Organophosphorus Pesticides
Polyvinyl chloride (PVC) can be used to develop reaction beaker which acts as electrochemical cell for the measurement of OP pesticides. Being chemically inert, corrosion resistant, and easy in molding to various shapes and size, PVC can be used for the immobilization of enzyme. Organophosphorus hydrolase was immobilized covalently onto the chemically activated inner surface of PVC beaker by using glutaraldehyde as a coupling agent. The carbon nanotubes paste working electrode was constructed for amperometric measurement at a potential of +0.8 V. The biosensor showed optimum response at pH 8.0 with incubation temperature of 40°C.andfor substrate (methyl parathion) were 322.58 µM and 1.1 µA, respectively. Evaluation study showed a correlation of 0.985, which was in agreement with the standard method. The OPH biosensor lost 50% of its initial activity after its regular use for 25 times over a period of 50 days when stored in 0.1 M sodium phosphate buffer, pH 8.0 at 4°C. No interference was observed by interfering species.- 24 December 2014
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2014, 1-8
Open AccessPreparation of Electrochemical Biosensor for Detection of Organophosphorus Pesticides
Polyvinyl chloride (PVC) can be used to develop reaction beaker which acts as electrochemical cell for the measurement of OP pesticides. Being chemically inert, corrosion resistant, and easy in molding to various shapes and size, PVC can be used for the immobilization of enzyme. Organophosphorus hydrolase was immobilized covalently onto the chemically activated inner surface of PVC beaker by using glutaraldehyde as a coupling agent. The carbon nanotubes paste working electrode was constructed for amperometric measurement at a potential of +0.8 V. The biosensor showed optimum response at pH 8.0 with incubation temperature of 40°C.andfor substrate (methyl parathion) were 322.58 µM and 1.1 µA, respectively. Evaluation study showed a correlation of 0.985, which was in agreement with the standard method. The OPH biosensor lost 50% of its initial activity after its regular use for 25 times over a period of 50 days when stored in 0.1 M sodium phosphate buffer, pH 8.0 at 4°C. No interference was observed by interfering species. - Open Access
- 9 December 2013
- Published by Wiley in Biochemistry Research International
- Vol. 2013, 1-18
Acetylcholinesterase Biosensors for Electrochemical Detection of Organophosphorus Compounds: A Review
The exponentially growing population, with limited resources, has exerted an intense pressure on the agriculture sector. In order to achieve high productivity the use of pesticide has increased up to many folds. These pesticides contain organophosphorus (OP) toxic compounds which interfere with the proper functioning of enzyme acetylcholinesterase (AChE) and finally affect the central nervous system (CNS). So, there is a need for routine, continuous, on spot detection of OP compounds which are the main limitations associated with conventional analytical methods. AChE based enzymatic biosensors have been reported by researchers as the most promising tool for analysis of pesticide level to control toxicity and for environment conservation. The present review summarises AChE based biosensors by discussing their characteristic features in terms of fabrication, detection limit, linearity range, time of incubation, and storage stability. Use of nanoparticles in recently reported fabrication strategies has improved the efficiency of biosensors to a great extent making them more reliable and robust.
- 9 December 2013
- Published by Wiley in Biochemistry Research International
- Vol. 2013, 1-18
Open AccessAcetylcholinesterase Biosensors for Electrochemical Detection of Organophosphorus Compounds: A Review
The exponentially growing population, with limited resources, has exerted an intense pressure on the agriculture sector. In order to achieve high productivity the use of pesticide has increased up to many folds. These pesticides contain organophosphorus (OP) toxic compounds which interfere with the proper functioning of enzyme acetylcholinesterase (AChE) and finally affect the central nervous system (CNS). So, there is a need for routine, continuous, on spot detection of OP compounds which are the main limitations associated with conventional analytical methods. AChE based enzymatic biosensors have been reported by researchers as the most promising tool for analysis of pesticide level to control toxicity and for environment conservation. The present review summarises AChE based biosensors by discussing their characteristic features in terms of fabrication, detection limit, linearity range, time of incubation, and storage stability. Use of nanoparticles in recently reported fabrication strategies has improved the efficiency of biosensors to a great extent making them more reliable and robust.