Guillaume A. Padmos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guillaume A. Padmos has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alida A. Postma
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands
1 shared publication - Alieske Kleeven
Department of Plastic, Reconstructive and Hand Surgery Maastricht University Medical Center Maastricht The Netherlands
1 shared publication Barbora Horehledova
Department of Clinical Imaging, Zuyderland Medical Center, Sittard-Geleen, the Netherlands
1 shared publication- Bianca M. Dijkstra
Department of Neurosurgery, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands
1 shared publication - Danielle B. P. Eekers
Department of Radiation Oncology (MAASTRO), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre , Maastricht
1 shared publication Eleftheria Karavolia
Department of Plastic, Reconstructive, and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
1 shared publication
Latest Publications
- Open Access
Non-Contrast MR T2-Weighted Imaging Is as Accurate as Contrast-Enhanced T1-Weighted Imaging in the Detection of Meningioma Growth
Background/Objectives: Asymptomatic meningiomas require frequent follow-up using MR imaging, with the standard of care being contrast-enhanced T1-weighted imaging (CE-T1WI) with Gadolinium-Based Contrast Agents (GBCAs). Limiting GBCA exposure reduces the environmental impact and limits possible gadolinium deposition in the brain. Therefore, the research objective was investigating the diagnostic accuracy of T2WI for evaluating significant meningioma growth (≥10% per year), using the CE-T1WI as reference standard. Methods: A total of 99 asymptomatic patients with the radiological diagnosis of meningioma and a minimum follow-up period of 11 months were retrospectively identified. Patients were scanned with various scanners in multiple hospitals. The maximum tumor diameter was measured in the transverse plane. Tumor growth was calculated in changes in millimeters and converted to percentages in the longest tumor diameter in the transverse plane. A paired-sample t-test was used to compare tumor growth on T2WI to CE-T1WI. The diagnostic accuracy of T2WI was determined by calculation of sensitivity, specificity, and positive and negative predictive values. Results: Mean follow-up time was 1.9 years. Significant tumor growth was found in 16 patients using T2WI, compared to 10 patients using CE-T1WI, which was not statistically significant. T2WI had a sensitivity of 80%, specificity of 90%, a positive predictive value of 47%, and negative predictive value of 98% for prediction of significant meningioma growth. Conclusions: T2WI was not inferior to CE-T1WI in the detection of significant tumor growth in asymptomatic meningioma and therefore can be used in follow-up to reduce gadolinium exposure.
Open AccessNon-Contrast MR T2-Weighted Imaging Is as Accurate as Contrast-Enhanced T1-Weighted Imaging in the Detection of Meningioma Growth
Background/Objectives: Asymptomatic meningiomas require frequent follow-up using MR imaging, with the standard of care being contrast-enhanced T1-weighted imaging (CE-T1WI) with Gadolinium-Based Contrast Agents (GBCAs). Limiting GBCA exposure reduces the environmental impact and limits possible gadolinium deposition in the brain. Therefore, the research objective was investigating the diagnostic accuracy of T2WI for evaluating significant meningioma growth (≥10% per year), using the CE-T1WI as reference standard. Methods: A total of 99 asymptomatic patients with the radiological diagnosis of meningioma and a minimum follow-up period of 11 months were retrospectively identified. Patients were scanned with various scanners in multiple hospitals. The maximum tumor diameter was measured in the transverse plane. Tumor growth was calculated in changes in millimeters and converted to percentages in the longest tumor diameter in the transverse plane. A paired-sample t-test was used to compare tumor growth on T2WI to CE-T1WI. The diagnostic accuracy of T2WI was determined by calculation of sensitivity, specificity, and positive and negative predictive values. Results: Mean follow-up time was 1.9 years. Significant tumor growth was found in 16 patients using T2WI, compared to 10 patients using CE-T1WI, which was not statistically significant. T2WI had a sensitivity of 80%, specificity of 90%, a positive predictive value of 47%, and negative predictive value of 98% for prediction of significant meningioma growth. Conclusions: T2WI was not inferior to CE-T1WI in the detection of significant tumor growth in asymptomatic meningioma and therefore can be used in follow-up to reduce gadolinium exposure.
- Open Access
- 16 April 2025
- Published by Elsevier in JPRAS Open
- Vol. 44, 511-523
Feasibility and safety of the Lymphatic Superficial Iliac Artery Perforator (L-SCIP) flap following inguinal lymph node dissection in reducing postoperative complications in patients with cancer
- 16 April 2025
- Published by Elsevier in JPRAS Open
- Vol. 44, 511-523
Open AccessFeasibility and safety of the Lymphatic Superficial Iliac Artery Perforator (L-SCIP) flap following inguinal lymph node dissection in reducing postoperative complications in patients with cancer