LGLeilane Glienke

Leilane Glienke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Leilane Glienke has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Timothy L. Hall

    Biomedical Engineering, University of Michigan, Ann Arbor, USA

    3 shared publications
  • William W. Roberts

    Department of Urology, University of Michigan, Ann Arbor, Michigan, USA

    3 shared publications
  • Khurshid R. Ghani

    Department of Urology, University of Michigan, Ann Arbor, Michigan, USA

    2 shared publications
  • Adam J. Matzger

    Department of Chemistry, University of Michigan, Ann Arbor, USA

    1 shared publication
  • Anthony F. Bonzagni

    Department of Urology, University of Michigan, Ann Arbor, Michigan, USA

    1 shared publication
  • John W. Robinson

    Department of Chemistry, University of Michigan, Ann Arbor, USA

    1 shared publication

Latest Publications

  • Improved control of renal pelvis pressure using a prototype fluid management system incorporating ureteroscope pressure feedback

    by Leilane Glienke, Anthony F. Bonzagni, Timothy L. Hall, Khurshid R. Ghani, William W. Roberts

    During ureteroscopy it is desirable to maintain renal pelvis pressure (PRP) below 40 cmH2O - the threshold for pyelovenous backflow - to decrease risk of infectious complications and postoperative pain. We sought to characterize PRP in a silicone kidney ureter model when using a prototype fluid management system (pFMS) that adjusts flowrate based on pressure feedback. These results were compared to conventional pressurized irrigation at five outflow resistance (ROUT) values. A LithoVue™ Elite ureteroscope was inserted into a silicone kidney ureter model with its tip in the renal pelvis. Irrigation was delivered from the pFMS with pressure limiter set to 40 cmH2O or from conventional pressurized irrigation at 50, 75, 100, 125, or 150 cmH2O. With pFMS irrigation, mean PRP remained below 40 cmH2O as ROUT was incremented from 0.9 to 4.9 cmH2O/(ml/min) respectively. With conventional pressurized irrigation, mean PRP increased as irrigation pressure increased and as ROUT increased. For example, when ROUT was 2.0 cmH2O/(ml/min), mean PRP was 37 cmH2O with both 125 cmH2O conventional irrigation pressure and pFMS. However, with higher ROUT values of 2.9, 4.0, and 4.9 cmH2O/(ml/min), mean PRP increased to 47, 57, and 60 cmH2O respectively with 125 cmH2O conventional irrigation pressure but was maintained below 40 cmH2O with the pFMS. Automated adjustment of irrigation based on pressure feedback is an effective way to control PRP and may reduce risk of infectious complications and postoperative pain.


  • Laser lithotripsy of a brushite crystalline aggregate stone model: fragment distribution vs. BegoStone and human stones

    by Leilane Glienke, John W. Robinson, Timothy L. Hall, Khurshid R. Ghani, Adam J. Matzger, William W. Roberts

    Laser research is hampered by a lack of accurate stone models that replicate fragmentation during laser lithotripsy. We sought to assess the distribution of stone fragments from laser ablation of new brushite crystalline powder and brushite crystalline aggregate stone models and compare with human stones and BegoStone. Samples of 15:3 and 15:5 BegoStone, powder, and aggregate model stones were tested alongside human CHPD and COM stone samples. All samples were secured and hydrated before Ho: YAG laser energy was delivered (Lumenis P120H) using a 200-micron D/F/L fiber. Lithotripsy was performed by repeatedly translating the fiber automatically through a predetermined grid of points (MATLAB program) until > 50% of each sample was ablated. Fragments were separated by sieving. For each stone type, 70.2–96.9% of the mass of fragments consisted of particles smaller than 0.25 mm. The percentage by mass of fragments greater than 1 mm in trials with 0.8 J x 10 Hz settings was 0.5%, 0.0%, 1.1% and 5.1% for BegoStone 15:3, BegoStone 15:5, powder model, and aggregate model respectively, compared to 5.5% for CHPD and 16.2% for COM. Only the aggregate model, CHPD and COM samples produced fragments > 2 mm. The new aggregate model stone better replicates the fragment distribution of human stones after laser lithotripsy. The method of producing the aggregate model stone - incorporating crystal and chemical components found in urinary stones - holds promise for developing better stone models needed to address a range of important lithotripsy research questions.


  • Sand clearance vs. flowrate during ureteroscopy: studies in an in-vitro transparent kidney model

    by Leilane Glienke, Timothy L. Hall, William W. Roberts

    Purpose Suction has recently been introduced into the ureteroscopic armamentarium to improve stone fragment and debris clearance. However, the benefits of suction appear to be limited by current irrigation systems. This study aimed to measure the time to clear sand ureteroscopically from a transparent silicone kidney-ureter model at different flowrates and compare with results with conventional pressurized irrigation and intermittent suction. Methods A LithoVue™ Elite ureteroscope was inserted through a Clear Petra 11/13 Fr 46 cm or 12/14 Fr 50 cm FANS device into a transparent silicone kidney model. Irrigation was delivered from a peristaltic pump at rates of 18–90 ml/min with pump assisted outflow or from a pressurized source with suction assisted outflow. Intrarenal pressure (IRP) was maintained between 30–40 cmH2O. Trials were conducted to measure the time required to completely aspirate 0.5 g of sand from the mid and upper calyces. Results Sand was cleared more quickly from the kidney model as flowrate increased up to ~ 70–80 ml/min. Use of continuous flowrate was more efficient at clearing sand than variable flowrate produced by bursts of intermittent suction. Conclusions Flowrate is a primary variable affecting efficiency of sand clearance in in vitro studies. Current clinical methods that utilize intermittent suction during ureteroscopy are likely less efficient than configurations that provide continuous flowrates. Incorporation of IRP feedback into irrigation systems may facilitate high flowrate while maintaining stable low IRP, thereby enhancing efficiency and safety of ureteroscopy.