Jiwoon Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiwoon Kwon has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hae Dong Park
Ocupational Safety and Health Research Institute, Korea Occupational, Safety and Health Agency, Ulsan 44429, Republic of Korea
1 shared publication - Hyunhee Park
Ocupational Safety and Health Research Institute, Korea Occupational, Safety and Health Agency, Ulsan 44429, Republic of Korea
1 shared publication Inja Choi
Wonjin Institute for Occupational and Environmental Health, 53, Sagajeong-ro 49-gil, Jungnang-gu, Seoul, 02221, Republic of Korea
1 shared publication- Kihyo Jung
School of Industrial Engineering, University of Ulsan, Ulsan 44610, Republic of Korea
1 shared publication - Sungho Kim
Ocupational Safety and Health Research Institute, Korea Occupational, Safety and Health Agency, Ulsan 44429, Republic of Korea
1 shared publication Won Kim
Wonjin Institute for Occupational and Environmental Health, 53, Sagajeong-ro 49-gil, Jungnang-gu, Seoul, 02221, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by Springer Nature in BMC Public Health
Association between perceived organizational prioritization of decontamination and firefighters’ exposure-control practices
- 4 November 2026
- Published by Springer Nature in BMC Public Health
Open AccessAssociation between perceived organizational prioritization of decontamination and firefighters’ exposure-control practices
- Open Access
- 14 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Surface polycyclic aromatic hydrocarbon contamination in fire stations across vehicles and personal protective equipment
This study investigated surface polycyclic aromatic hydrocarbon (PAH) contamination in fire stations using 121 wipe samples collected from indoor spaces, vehicles, and personal protective equipment (PPE) surfaces in three fire stations in South Korea, and identified key exposure sources in vehicles and PPE. Fire station surfaces exhibited significantly higher PAH concentrations than commercial office controls, with median total PAH (Σ17 PAHs) levels 69 times higher in fire vehicles (p < 0.001), 26 times higher in vehicle bays and PPE cabinets (both p = 0.044), and 24 times higher in fire offices (p = 0.003). Among vehicles, fire survey vehicles showed the highest surface Σ17 PAHs contamination, particularly on floors, where concentrations were significantly higher than those on seats (p = 0.021) and ceilings (p = 0.012). PPE contamination was highest on the outer ankle areas of boots, followed by gloves and boot soles. Notably, the inner surfaces of turnout pants and face shields had PAH levels comparable to those on their respective outer surfaces (p > 0.05), suggesting possible contaminant transfer, although inward contaminant infiltration could not be excluded. High-molecular-weight PAHs were more prevalent on vehicle floors and boot surfaces, indicating significant surface-associated exposure potential. These findings support the need for improved contamination control measures, including routine decontamination of vehicles and PPE, enhanced PPE design to minimize pollutant ingress, and targeted policy interventions to safeguard firefighter health.
- 14 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSurface polycyclic aromatic hydrocarbon contamination in fire stations across vehicles and personal protective equipment
This study investigated surface polycyclic aromatic hydrocarbon (PAH) contamination in fire stations using 121 wipe samples collected from indoor spaces, vehicles, and personal protective equipment (PPE) surfaces in three fire stations in South Korea, and identified key exposure sources in vehicles and PPE. Fire station surfaces exhibited significantly higher PAH concentrations than commercial office controls, with median total PAH (Σ17 PAHs) levels 69 times higher in fire vehicles (p < 0.001), 26 times higher in vehicle bays and PPE cabinets (both p = 0.044), and 24 times higher in fire offices (p = 0.003). Among vehicles, fire survey vehicles showed the highest surface Σ17 PAHs contamination, particularly on floors, where concentrations were significantly higher than those on seats (p = 0.021) and ceilings (p = 0.012). PPE contamination was highest on the outer ankle areas of boots, followed by gloves and boot soles. Notably, the inner surfaces of turnout pants and face shields had PAH levels comparable to those on their respective outer surfaces (p > 0.05), suggesting possible contaminant transfer, although inward contaminant infiltration could not be excluded. High-molecular-weight PAHs were more prevalent on vehicle floors and boot surfaces, indicating significant surface-associated exposure potential. These findings support the need for improved contamination control measures, including routine decontamination of vehicles and PPE, enhanced PPE design to minimize pollutant ingress, and targeted policy interventions to safeguard firefighter health.
- Open Access
Personal Noise Exposure Assessment and Noise Level Prediction Through Worst-Case Scenarios for Korean Firefighters
Firefighters experience high noise levels from various sources, such as sirens, alarms, pumps, and emergency vehicles. Unlike industrial workers who experience continuous noise exposure, firefighters are subject to intermittent high-intensity noise, increasing their risk of noise-induced hearing loss (NIHL). Despite global concerns regarding firefighters’ auditory health, research on Korean firefighters remains limited. This study aimed to assess personal noise exposure among Korean firefighters across three primary job roles—fire suppression, rescue, and emergency medical services (EMS)—and to predict worst-case noise exposure scenarios. This study included 115 firefighters from three fire stations (one urban, two suburban). We measured personal noise exposure using dosimeters attached near the ear following the Korean Ministry of Employment and Labor (MOEL) and International Organization for Standardization (ISO) criteria. Measurements included threshold levels of 80 dBA, exchange rates of 5 dB (MOEL) and 3 dB (ISO), and a peak noise criterion of 140 dBC. We categorized firefighters’ activities into routine tasks (shift handovers, equipment checks, training) and emergency responses (fire suppression, rescues, EMS calls). We performed statistical analyses to compare noise levels across job roles, vehicle types, and specific tasks. The worst-case exposure scenarios were estimated using 10th percentile recorded noise levels. The average 8 h time-weighted noise exposure levels varied significantly by job role. Rescue personnel exhibited the highest mean noise exposure (MOEL: 71.4 dBA, ISO: 81.2 dBA; p < 0.05), whereas fire suppression (MOEL: 66.5 dBA, ISO: 74.2 dBA) and EMS personnel (MOEL: 68.6 dBA, ISO: 73.0 dBA) showed no significant difference. Peak noise levels exceeding 140 dBC were most frequently observed in rescue operations (33.3%), followed by fire suppression (30.2%) and EMS (27.2%). Among vehicles, noise exposure was the highest for rescue truck occupants. Additionally, EMS personnel inside ambulances had significantly higher noise levels than drivers (p < 0.05). Certain tasks, including shift handovers, equipment checks, and firefighter training, recorded noise levels exceeding 100 dBA. Worst-case scenario predictions indicated that some work conditions could lead to 8 h average exposures surpassing MOEL (91.4 dBA) and ISO (98.7 dBA) limits. In this study, Korean firefighters exhibited relatively low average noise levels. However, when analyzing specific tasks, exposure was sufficiently high enough to cause hearing loss. Despite NIHL risks, firefighters rarely used hearing protection, particularly during routine tasks. This emphasizes the urgent need for hearing conservation programs, including mandatory hearing protection during high-noise activities, noise exposure education, and the adoption of communication-friendly protective devices. Future research should explore long-term auditory health outcomes and assess the effectiveness of noise control measures.
Open AccessPersonal Noise Exposure Assessment and Noise Level Prediction Through Worst-Case Scenarios for Korean Firefighters
Firefighters experience high noise levels from various sources, such as sirens, alarms, pumps, and emergency vehicles. Unlike industrial workers who experience continuous noise exposure, firefighters are subject to intermittent high-intensity noise, increasing their risk of noise-induced hearing loss (NIHL). Despite global concerns regarding firefighters’ auditory health, research on Korean firefighters remains limited. This study aimed to assess personal noise exposure among Korean firefighters across three primary job roles—fire suppression, rescue, and emergency medical services (EMS)—and to predict worst-case noise exposure scenarios. This study included 115 firefighters from three fire stations (one urban, two suburban). We measured personal noise exposure using dosimeters attached near the ear following the Korean Ministry of Employment and Labor (MOEL) and International Organization for Standardization (ISO) criteria. Measurements included threshold levels of 80 dBA, exchange rates of 5 dB (MOEL) and 3 dB (ISO), and a peak noise criterion of 140 dBC. We categorized firefighters’ activities into routine tasks (shift handovers, equipment checks, training) and emergency responses (fire suppression, rescues, EMS calls). We performed statistical analyses to compare noise levels across job roles, vehicle types, and specific tasks. The worst-case exposure scenarios were estimated using 10th percentile recorded noise levels. The average 8 h time-weighted noise exposure levels varied significantly by job role. Rescue personnel exhibited the highest mean noise exposure (MOEL: 71.4 dBA, ISO: 81.2 dBA; p < 0.05), whereas fire suppression (MOEL: 66.5 dBA, ISO: 74.2 dBA) and EMS personnel (MOEL: 68.6 dBA, ISO: 73.0 dBA) showed no significant difference. Peak noise levels exceeding 140 dBC were most frequently observed in rescue operations (33.3%), followed by fire suppression (30.2%) and EMS (27.2%). Among vehicles, noise exposure was the highest for rescue truck occupants. Additionally, EMS personnel inside ambulances had significantly higher noise levels than drivers (p < 0.05). Certain tasks, including shift handovers, equipment checks, and firefighter training, recorded noise levels exceeding 100 dBA. Worst-case scenario predictions indicated that some work conditions could lead to 8 h average exposures surpassing MOEL (91.4 dBA) and ISO (98.7 dBA) limits. In this study, Korean firefighters exhibited relatively low average noise levels. However, when analyzing specific tasks, exposure was sufficiently high enough to cause hearing loss. Despite NIHL risks, firefighters rarely used hearing protection, particularly during routine tasks. This emphasizes the urgent need for hearing conservation programs, including mandatory hearing protection during high-noise activities, noise exposure education, and the adoption of communication-friendly protective devices. Future research should explore long-term auditory health outcomes and assess the effectiveness of noise control measures.