Solange Travassos de Figueiredo Alves
Research Subjects
Solange Travassos de Figueiredo Alves has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- André Luís Do Nascimento Ferreira1 shared publication
- Carlos Roberto Lyra da Silva
Universidade Federal do Estado do Rio de Janeiro
1 shared publication - Esther Cytrynbaum Young
School of Medicine and Surgery, Federal University of Rio de Janeiro State (UNIRIO), Rio de Janeiro, Brazil
1 shared publication - Mariana de Almeida Pinto Borges1 shared publication
- Monique Souza Furtado1 shared publication
- Nébia Maria Almeida de Figueiredo
Universidade Federal do Estado do Rio de Janeiro
1 shared publication
Latest Publications
- Open Access
- 4 January 2025
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 18 (1) , e14255
Effectiveness of flash monitoring technology in the glycemic control of patients with I Diabetes Mellitus
Objective: to evaluate the effectiveness of the Flash glucose device compared to the Accu Chek glucometer in Type 1 Diabetes Mellitus (T1DM). Methods: thirty patients with T1DM and age over 18 years, treated at a tertiary hospital, were recruited. To verify the effectiveness of the FGM device, the average proportion of blood glucose levels in the target (range 70 to 180 mg/dL), level 2 hyperglycemia (> 250mg/dL) and level 2 hypoglycemia (<54mg/dL) were evaluated separately. Subsequently, the proportion of blood glucose in these ranges was compared between the two devices. Results: the use of the FGM, when compared to the Accu-Chek system, made it possible to increase the proportion of blood glucose levels on Time in Range (70 to 180 mg/dl) by 51% (Libre 65% & Accu-Chek 43%) and the reduction in level 2 hyperglycemia of 90.48% (Libre 2% versus Accu-Check 21%). However, the FGM system was not able to reduce the level 2 hypoglycemia occurrence. Conclusions: the Flash monitoring technology seem an effective tool for glycemic control in patients with T1DM.
- 4 January 2025
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 18 (1) , e14255
Open AccessEffectiveness of flash monitoring technology in the glycemic control of patients with I Diabetes Mellitus
Objective: to evaluate the effectiveness of the Flash glucose device compared to the Accu Chek glucometer in Type 1 Diabetes Mellitus (T1DM). Methods: thirty patients with T1DM and age over 18 years, treated at a tertiary hospital, were recruited. To verify the effectiveness of the FGM device, the average proportion of blood glucose levels in the target (range 70 to 180 mg/dL), level 2 hyperglycemia (> 250mg/dL) and level 2 hypoglycemia (<54mg/dL) were evaluated separately. Subsequently, the proportion of blood glucose in these ranges was compared between the two devices. Results: the use of the FGM, when compared to the Accu-Chek system, made it possible to increase the proportion of blood glucose levels on Time in Range (70 to 180 mg/dl) by 51% (Libre 65% & Accu-Chek 43%) and the reduction in level 2 hyperglycemia of 90.48% (Libre 2% versus Accu-Check 21%). However, the FGM system was not able to reduce the level 2 hypoglycemia occurrence. Conclusions: the Flash monitoring technology seem an effective tool for glycemic control in patients with T1DM.