Navdeep Tangri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Navdeep Tangri has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Danielle Jeddah
Department of Clinical Development, Healthy.io , Boston, MA
1 shared publication - Matan Ronen
Healthy.io
1 shared publication Nicholas B Bevins
BirdRock Laboratories
1 shared publication
Latest Publications
- Open Access
Diagnostic Accuracy of a Smartphone-Enabled Urinary Albumin-to-Creatinine Ratio Test for Detecting Chronic Kidney Disease Among At-Risk Populations
Objective To evaluate the diagnostic accuracy of the FDA-cleared Minuteful Kidney Test (MKT), a home-based semi-quantitative urine albumin-to-creatinine ratio (uACR) test, compared to the Beckman Coulter AU 480 analyzer, a standard laboratory quantitative method, for detecting albuminuria in individuals with or at risk for chronic kidney disease (CKD). Methods Urine samples were obtained from individuals with risk factors for kidney damage. Each sample was analyzed for uACR using both the MKT and the laboratory standard method. Albuminuria was classified according to KDIGO guidelines: A1 (uACR ≤30 mg/g, “Normal to mildly increased”), A2 (uACR 30-300 mg/g, “Moderately increased”), and A3 (uACR ≥300 mg/g, “Severely increased”). Sensitivity, specificity, PPV, and NPV of MKT were calculated against the laboratory standard. Results Out of 615 collected urine samples, 555 met inclusion criteria. Albuminuria (uACR ≥30 mg/g) was detected in 24.9% of samples using the laboratory method (95% CI, 21.3–28.5%). The MKT demonstrated a sensitivity of 96.4%, specificity of 84.2%, NPV of 98.6%, and PPV of 66.8%. The test accurately categorized 85.6% of samples into the KDIGO albuminuria categories A1, A2, and A3, accurately identifying 100% of laboratory-confirmed A3 samples as abnormal. Conclusions The Minuteful Kidney Test shows high sensitivity, exceeding the guideline-required threshold (>85%, P<0.001), and robust specificity for detecting albuminuria in high-risk populations. This device offers potential to improve CKD screening and management and facilitate early intervention in primary care and community settings, where accurate rule-out capabilities are essential.
Open AccessDiagnostic Accuracy of a Smartphone-Enabled Urinary Albumin-to-Creatinine Ratio Test for Detecting Chronic Kidney Disease Among At-Risk Populations
Objective To evaluate the diagnostic accuracy of the FDA-cleared Minuteful Kidney Test (MKT), a home-based semi-quantitative urine albumin-to-creatinine ratio (uACR) test, compared to the Beckman Coulter AU 480 analyzer, a standard laboratory quantitative method, for detecting albuminuria in individuals with or at risk for chronic kidney disease (CKD). Methods Urine samples were obtained from individuals with risk factors for kidney damage. Each sample was analyzed for uACR using both the MKT and the laboratory standard method. Albuminuria was classified according to KDIGO guidelines: A1 (uACR ≤30 mg/g, “Normal to mildly increased”), A2 (uACR 30-300 mg/g, “Moderately increased”), and A3 (uACR ≥300 mg/g, “Severely increased”). Sensitivity, specificity, PPV, and NPV of MKT were calculated against the laboratory standard. Results Out of 615 collected urine samples, 555 met inclusion criteria. Albuminuria (uACR ≥30 mg/g) was detected in 24.9% of samples using the laboratory method (95% CI, 21.3–28.5%). The MKT demonstrated a sensitivity of 96.4%, specificity of 84.2%, NPV of 98.6%, and PPV of 66.8%. The test accurately categorized 85.6% of samples into the KDIGO albuminuria categories A1, A2, and A3, accurately identifying 100% of laboratory-confirmed A3 samples as abnormal. Conclusions The Minuteful Kidney Test shows high sensitivity, exceeding the guideline-required threshold (>85%, P<0.001), and robust specificity for detecting albuminuria in high-risk populations. This device offers potential to improve CKD screening and management and facilitate early intervention in primary care and community settings, where accurate rule-out capabilities are essential.