YYYonggang Yue

Yonggang Yue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yonggang Yue has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surface Potential Decay Characteristics and Trap Regulation Mechanism of Epoxy Glass Fiber Under Low-Temperature Gradient

    by Yongqiang Fan, Shuhan Peng, Jianzhong Yang, Aoqi Jia, Yun Bai, Zhihui Li, Xiaoyun Tian, Yonggang Yue

    Surface charge accumulation and trap distribution are the core factors affecting the surface flashover characteristics of insulating materials. Considering the low-temperature gradient environment of superconducting energy pipeline terminations, this paper systematically studies the surface charge dynamic characteristics and trap distribution law of epoxy glass fiber (GFRP) by using the isothermal surface potential decay (ISPD) method combined with finite element simulation. A temperature-controlled ISPD test platform of −30~20 °C (193~293 K) was built to measure the surface potential decay curves at different temperatures and calculate the trap energy level and density; a charge migration model considering temperature gradient was established to analyze the influence of trapped charges on surface potential and electric field distribution. The results show that low temperature significantly reduces the surface potential decay rate (the residual potential after 5000 s is 92.91% of the initial value at 193 K, and only 3.51% at 293 K); the traps of GFRP at 193 K are dominated by deep traps (central energy level 0.68 eV, density 1.63 × 1020 m−3·eV), while there is a bimodal distribution of shallow traps (0.92 eV) and deep traps (0.98 eV) at 293 K; under temperature gradient, the accumulation of deep trap charges in the low-temperature region leads to a surface electric field distortion rate of 12.60, which is the key microscopic mechanism for the decrease of flashover voltage.


  • Open Access

    Finite-Element Simulations of the Static Behavior and Explosive-Rupture Dynamics of 500 kV SF6 Porcelain Hollow Bushings

    by Yonggang Yue, Jianli Zhao, Lanjun Yang, Zhijian Lu

    We investigate the explosive-rupture behavior of porcelain hollow bushings using a representative 500 kV SF6 incident as the reference case. Finite-element simulations are performed for both the static response and the rupture process. Results show that internal SF6 pressure drives the maximum equivalent (von Mises) stress to the flange, while strain localizes near the bushing mid-span. These findings highlight the cement–grout potting between the porcelain shell and flange, the waterproofing treatment, and the mid-span bonded joint as key manufacturing control points. Dynamic simulations further indicate that comparing the explosive-equivalent energy of the SF6 pressure impulse with the gas expansion (burst) energy enables diagnosis of the failure mode. From the viewpoint of fragment kinetic energy, the analysis indirectly verifies that rupture is initiated by intrinsic porcelain defects and subsequent crack propagation. The simulated fragment morphology and ground dispersion agree with field observations from the actual event, underscoring the critical role of microcracks in brittle fracture. Accordingly, optimizing firing processes to reduce internal cracks and voids—via raw-material control and firing-temperature optimization—is essential for reliability improvement and life extension. The results provide a practical reference for the design and long-term operation of porcelain bushings.


  • Open Access

    Study on the Unipolar Impulse Aging Characteristics of ZnO Varistors and Their Condition Monitoring Methods

    by Yongqiang Fan, Wenkai Meng, Xiaoyun Tian, Yonggang Yue, Zhihui Li, Minxin Xu, Xinyan Xiao, Lanjun Yang

    Metal-oxide surge arresters (MOSAs) are critical devices for overvoltage protection in power systems, and the aging characteristics of their zinc oxide (ZnO) varistors under impulse and power-frequency voltages exhibit significant differences. However, traditional methods for monitoring the aging state of surge arresters suffer from limitations such as insufficient sensitivity and vulnerability to harmonic interference. Therefore, this study conducted accelerated aging experiments on ZnO varistor samples under negative-polarity impulse currents. Key parameters were measured, including the DC reference voltage, the DC leakage current, nonlinear coefficients, and the full current under harmonic-containing power-frequency voltage at a voltage ratio of 0.6. The resistive component was accurately extracted from the full current using a separation method based on the Levenberg–Marquardt (LM) optimization algorithm. Spectral analysis was then performed on both the full current and the extracted resistive current components. The experimental results demonstrate a significant polarity effect in the aging of ZnO varistors under unipolar impulse currents. The LM optimization algorithm enables precise extraction of the resistive current component from the full current. Furthermore, compared to the fundamental and third harmonic components, the amplitude of the DC component within the resistive current exhibits the highest sensitivity to aging, establishing it as a viable aging criterion.


  • Open Access

    Influence of free charges on flashover of silicone rubber surface with droplet covered

    by Yonggang Yue, Bangkai Qian, Bin Cao, Fanghui Yin, Xiaobo Meng, Liming Wang

    Due to the excellent hydrophobicity and transfer property, the flashover performance of silicone rubber composite insulators is considerably higher than that of porcelain and glass insulators. To investigate the flashover process on a water-droplet-covered hydrophobic surface, a water droplet was put on the hydrophobic surface, which was subjected to a uniform AC electric field strength. The dynamics of the micro-water droplet were observed using a high-speed camera. With the increase in the electric field, the state of the water droplet changed from static to a symmetric oscillation. However, with the electric field increased further, free charges were generated by corona discharge. With the presence of free charges, the strong Coulomb force played a critical role in the flashover process on the water-droplet-covered hydrophobic surface. It would not only change the oscillation of water droplets into an asymmetrical pattern but also dramatically elongate the water droplet, which favored the occurrence of flashover. This explains well that flashover normally occurs for a few cycles after the start of asymmetric oscillation.


  • Sensitivity Analysis of Hydrostatic Test for Defect-Elimination in Ultrahigh Voltage and Large-Tonnage Insulators

    by Yonggang Yue, Weiyun Li, Yanxin Tu, Mingzhe Yi, Bin Cao, Liming Wang

    Porcelain insulators are essential for the mechanical and electrical reliability of overhead transmission lines, especially in Ultra High Voltage (UHV) systems. Manufacturing defects such as pores, impurities, and microcracks can threaten their integrity under stress. Hydrostatic test is widely used as a quality control method, but its parameters are often based on experience, with limited understanding of its effectiveness in detecting specific defects. This study quantitatively evaluates the sensitivity of hydrostatic test to typical defect types in large-tonnage porcelain insulators. Finite element simulations were conducted to analyze how defect size, shape, and material properties influence stress distribution. The results provide insights into the defect elimination mechanisms of hydrostatic test and support the development of the more standardized and effective testing procedures.

  • Design of power supply for pollution flashover test under superimposed AC/DC voltage

    by Yonggang Yue, Hongchuan Dong, Liang Li, Yanxin Tu, Bin Cao, Liming Wang

    Insulators are critical components in power systems, and pollution flashover presents a significant threat to their operational safety. Historically, research on pollution flashover has focused on conditions involving a single voltage type. However, with the rapid development and widespread adoption of flexible Direct Current (DC) transmission systems, insulators are increasingly exposed to complex operating conditions involving Alternating Current (AC)–DC composite voltages. This study investigates the flashover behavior of insulators under AC–DC composite voltage conditions. To achieve this, a novel AC–DC superimposed power supply system was developed, capable of generating varying 1:3 and 1:1 ratios of AC and DC components. The system’s dynamic output characteristics were analyzed through theoretical calculations and simulation, with a focus on steady-state and transient-state behaviors. The power supply system was then utilized to conduct artificial pollution flashover tests on insulators. Results indicate that the inclusion of a DC component in the AC voltage significantly lowers the AC voltage required to initiate flashover, with larger DC components resulting in greater reductions. These findings offer valuable insights for the design and selection of insulators operating under AC–DC composite voltage conditions and establish a foundation for further research into insulator performance under mixed voltage environments.


  • Causes Analysis of Burst Fault for 500 kV Porcelain Bushing Based on Explosion Theory

    by Jianli Zhao, Yonggang Yue, Zhuo Liu, Shuhua Yao, Lanjun Yang

  • Open Access

    Insulation Defect Detection of Solid Insulating Material Based on Nanosecond Pulse Voltage

    by Yang Jianzhong, An Shengdongt, Fan Yongqiang, Yin Jianbo, Yue Yonggang

    In this paper, a partial discharge detection platform with repeated frequency nanosecond pulse voltage is built. Its output voltage is 30kV, the pulse front is 100ns, the half-width of the voltage is 120ns, and the maximum repetition frequency is 10 kHz. Under the excitation of nanosecond pulse voltage, the defects in the test sample produce partial discharge, the number of partial discharge is consistent with the number of applied pulses, the repeatability of discharge is good, the discharge quantity and the initial discharge voltage are easy to be counted, the partial discharge parameters are easy to be extracted. Under continuous pulses excitation, the development of defect of the sample can be judged by the change process of the discharge amount. Therefore, the nanosecond pulse voltage can be used to detect the insulation defect of the sample, and it is helpful to study the destruction process and mechanism of the solid insulating material under partial discharge.

  • Open Access

    A Guided Wave Transducer with Sprayed Magnetostrictive Powder Coating for Monitoring of Aluminum Conductor Steel-Reinforced Cables

    by Fuzai Lv, Pengfei Zhang, Zhifeng Tang, Yonggang Yue, Keji Yang

    Aluminum conductor steel-reinforced (ACSR) cables are typically used in overhead transmission lines, requiring stringent non-destructive testing owing to the severe conditions they face. Ultrasonic guided wave inspection provides promising online monitoring of the wire breakage of cables with the advantages of high sensitivity, long-range inspection, and full cross-sectional coverage. It is a very popular method to generate and receive guided waves using magnetostrictive and piezoelectric transducers. However, uniformly coupling the acoustic energy excited by transducers into multi-wire structures is always a challenge in the field application of guided waves. Long-term field application of piezoelectric transducers is limited due to the small coupling surface area, localized excitation, and couplant required. Conventional magnetostrictive transducers for steel strand inspection are based on the magnetostrictive effect of the material itself. Two factors affect the transducing performance of the transducers on ACSR cables. On one hand, there is a non-magnetostrictive effect in aluminum wires. On the other hand, the magnetostriction of the innermost steel wires is too weak to generate guided waves. The bias magnetic field is attenuated by the outer layers of aluminum wires. In this paper, an alternative sprayed magnetostrictive powder coating (SMPC) transducer was developed for guided wave generation and detection in ACSR cables. The Fe83Ga17 alloy powder with large magnetostriction was sprayed uniformly on the surfaces of certain sections of the outermost aluminum wires where the transducer would be installed. Experimental investigations were carried out to generate and receive the most commonly used L(0,1) guided waves for wire breakage detection at frequencies of 50 and 100 kHz. The results demonstrate that the discernable reflected waves of the cable end and an artificial defect of three-wire breakage (5.5% reduction in the cable’s cross-sectional area) were received by the transducer with SMPC, which was impossible for the transducer without SMPC. This method makes long-term and online monitoring of ACSR cables feasible due to the high coupling efficiency and good structural surface adaptability.