Sachiko Matsuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sachiko Matsuda has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dulamjav Jamsransuren
Research Center for Global Agromedicine, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada, Obihiro 080-8555, Hokkaido, Japan
2 shared publications - Haruko Ogawa
Department of Veterinary Medicine, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada, Obihiro, Hokkaido 080-8555, Japan
2 shared publications - Yohei Takeda
Department of Veterinary Medicine, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada, Obihiro, Hokkaido 080-8555, Japan
2 shared publications - James Gitau Komu
Graduate School of Animal and Veterinary Sciences and Agriculture, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada, Obihiro 080-8555, Hokkaido, Japan
1 shared publication - Koichi Narita
Faculty of Pharmaceutical Sciences, Tohoku Medical and Pharmaceutical University, 4-4-1 Komatsushima, Aoba-ku, Sendai 981-8558, Japan
1 shared publication - Mayar Yasser Zeinelabideen Mohamed
Department of Veterinary Medicine, Obihiro University of Agriculture and Veterinary Medicine, 2-11 Inada, Obihiro 080-8555, Japan
1 shared publication
Latest Publications
- Open Access
- 16 July 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (14) , 1791
Performance Evaluation of a Fully Automated Molecular Diagnostic System for Multiplex Detection of SARS-CoV-2, Influenza A/B Viruses, and Respiratory Syncytial Virus
Background/Objectives: Concurrent outbreaks of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza A and B viruses (IAV/IBV), and respiratory syncytial virus (RSV) necessitate rapid and precise differential laboratory diagnostic methods. This study aimed to evaluate the multiplex molecular diagnostic performance of the geneLEAD VIII system (Precision System Science Co., Ltd., Matsudo, Japan), a fully automated sample-to-result precision instrument, in conjunction with the VIASURE SARS-CoV-2, Flu & RSV Real Time PCR Detection Kit (CerTest Biotec, S.L., Zaragoza, Spain). Methods: The specific detection capabilities of SARS-CoV-2, IAV/IBV, and RSV genes were evaluated using virus-spiked saliva and nasal swab samples. Using saliva samples, the viral titer detection limits of geneLEAD/VIASURE and manual referent singleplex RT-qPCR assays were compared. The performance of geneLEAD/VIASURE in analyzing single- and multiple-infection models was scrutinized. The concordance between the geneLEAD/VIASURE and the manual assays was assessed. Results: The geneLEAD/VIASURE successfully detected all the virus genes in the saliva and nasal swab samples despite some differences in the Ct values. The viral titer detection limits in the saliva samples for SARS-CoV-2, IAV, IBV, and RSV using geneLEAD/VIASURE were 100, ≤10−2, 100, and 102 TCID50/mL, respectively, compared to ≤10−1, ≤100, ≤100, and ≤104 TCID50/mL, respectively, in the manual assays. geneLEAD/VIASURE yielded similar Ct values in the single- and multiple-infection models, with some exceptions noted in the triple-infection models when low titers of RSV were spiked with high titers of the other viruses. The concordance between geneLEAD/VIASURE and the manual assays was high, with Pearson’s R2 values of 0.90, 0.85, 0.92, and 0.95 for SARS-CoV-2, IAV, IBV, and RSV, respectively. Conclusions: geneLEAD/VIASURE is a reliable diagnostic tool for detecting SARS-CoV-2, IAV/IBV, and RSV in single- and multiple-infection scenarios.
- 16 July 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (14) , 1791
Open AccessPerformance Evaluation of a Fully Automated Molecular Diagnostic System for Multiplex Detection of SARS-CoV-2, Influenza A/B Viruses, and Respiratory Syncytial Virus
Background/Objectives: Concurrent outbreaks of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza A and B viruses (IAV/IBV), and respiratory syncytial virus (RSV) necessitate rapid and precise differential laboratory diagnostic methods. This study aimed to evaluate the multiplex molecular diagnostic performance of the geneLEAD VIII system (Precision System Science Co., Ltd., Matsudo, Japan), a fully automated sample-to-result precision instrument, in conjunction with the VIASURE SARS-CoV-2, Flu & RSV Real Time PCR Detection Kit (CerTest Biotec, S.L., Zaragoza, Spain). Methods: The specific detection capabilities of SARS-CoV-2, IAV/IBV, and RSV genes were evaluated using virus-spiked saliva and nasal swab samples. Using saliva samples, the viral titer detection limits of geneLEAD/VIASURE and manual referent singleplex RT-qPCR assays were compared. The performance of geneLEAD/VIASURE in analyzing single- and multiple-infection models was scrutinized. The concordance between the geneLEAD/VIASURE and the manual assays was assessed. Results: The geneLEAD/VIASURE successfully detected all the virus genes in the saliva and nasal swab samples despite some differences in the Ct values. The viral titer detection limits in the saliva samples for SARS-CoV-2, IAV, IBV, and RSV using geneLEAD/VIASURE were 100, ≤10−2, 100, and 102 TCID50/mL, respectively, compared to ≤10−1, ≤100, ≤100, and ≤104 TCID50/mL, respectively, in the manual assays. geneLEAD/VIASURE yielded similar Ct values in the single- and multiple-infection models, with some exceptions noted in the triple-infection models when low titers of RSV were spiked with high titers of the other viruses. The concordance between geneLEAD/VIASURE and the manual assays was high, with Pearson’s R2 values of 0.90, 0.85, 0.92, and 0.95 for SARS-CoV-2, IAV, IBV, and RSV, respectively. Conclusions: geneLEAD/VIASURE is a reliable diagnostic tool for detecting SARS-CoV-2, IAV/IBV, and RSV in single- and multiple-infection scenarios.
- Open Access
In Vitro Influenza A Virus-Inactivating Activity of HIDROX®, Hydroxytyrosol-Rich Aqueous Olive Pulp Extract
Influenza A virus (IAV) is an important respiratory pathogen. We evaluated the IAV-inactivation activity of hydroxytyrosol (HT)-rich aqueous olive pulp extract (HIDROX®) and its mechanisms. The HIDROX-containing solution and cream showed concentration- and time-dependent virucidal activity. The virucidal activity of HIDROX was higher than pure HT. With Western blotting (WB), the band intensities of multiple viral structural proteins in HIDROX- and HT-treated viruses were weaker than in the control, and high-molecular-mass bands were observed. These results suggest that HIDROX and HT may have induced the structural changes or abnormalities of viral proteins. HIDROX and HT had no or limited impact on hemagglutination and neuraminidase activities, as well as the virus genome. No apparent abnormalities in the viral particles were observed through electron microscopy following treatment with HIDROX and HT. Treatment with HT, but not HIDROX, resulted in the production of high levels of reactive oxygen species (ROS) and/or reactive nitrogen species (RNS). In HT treatment but not HIDROX treatment, the virucidal activity disappeared, and the induction of abnormal band patterns of a viral protein in WB was cancelled by ROS/RNS scavenger activity. These findings showed the possible utility of HIDROX as a naturally derived IAV virucidal component that may contribute to IAV control.
Open AccessIn Vitro Influenza A Virus-Inactivating Activity of HIDROX®, Hydroxytyrosol-Rich Aqueous Olive Pulp Extract
Influenza A virus (IAV) is an important respiratory pathogen. We evaluated the IAV-inactivation activity of hydroxytyrosol (HT)-rich aqueous olive pulp extract (HIDROX®) and its mechanisms. The HIDROX-containing solution and cream showed concentration- and time-dependent virucidal activity. The virucidal activity of HIDROX was higher than pure HT. With Western blotting (WB), the band intensities of multiple viral structural proteins in HIDROX- and HT-treated viruses were weaker than in the control, and high-molecular-mass bands were observed. These results suggest that HIDROX and HT may have induced the structural changes or abnormalities of viral proteins. HIDROX and HT had no or limited impact on hemagglutination and neuraminidase activities, as well as the virus genome. No apparent abnormalities in the viral particles were observed through electron microscopy following treatment with HIDROX and HT. Treatment with HT, but not HIDROX, resulted in the production of high levels of reactive oxygen species (ROS) and/or reactive nitrogen species (RNS). In HT treatment but not HIDROX treatment, the virucidal activity disappeared, and the induction of abnormal band patterns of a viral protein in WB was cancelled by ROS/RNS scavenger activity. These findings showed the possible utility of HIDROX as a naturally derived IAV virucidal component that may contribute to IAV control.