HSHarlen Sihotang

Harlen Sihotang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harlen Sihotang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ANALISA PAPAN REKLAME NAMA TOKO TERHADAP KUALITAS VISUAL DAN VISIBILITAS

    by Endi Martha Mulia, Harlen Sihotang, Jansen Wijaya, Immanuelly Agustine Putri Limada

    The rapid growth of development and business in Medan City has driven the use of billboards as an effective promotional medium. In the area of Jalan Putri Hijau Merak Jingga to Jalan Perintis Kemerdekaan, store signage billboards appear densely packed and disorganized. This study aims to analyze the visual quality and visibility of billboards in that area in relation to the buildings. The research uses a qualitative method, with data collected directly on-site and analyzed using a research formula consisting of variables such as proportion and scale, color, harmony and contrast, and viewing distance. The results show that the visual quality of the billboards in this area is low and does not align with existing visual aesthetic theories for signage on buildings. However, in terms of visibility (viewing distance), the billboards are considered to comply with existing theory. This study highlights the importance of proper billboard placement aligned with visual aesthetics and functional clarity.

  • Open Access

    METODE PELAKSANAAN PENGUJIAN PONDASI TIANG PANCANG MENGGUNAKAN (PDA TEST) PADA PROYEK PEMBANGUNAN GEDUNG PORTIR DAN AULA LAPAS KELAS I MEDAN

    by Harlen Sihotang, Alfin Panjaitan

    In proving the strength of the finished pile foundation, further testing must be carried out. The Medan Class I Porter Building and Penitentiary Hall Construction Project was carried out by the PDA test (Pile Driving Analyzer) which is a dynamic test used to measure the bearing capacity of piles, ultimate axial compressive resistance of piles, and so on. The aim of this research is to ascertain and ascertain whether the method for carrying out PDA testing carried out in the Medan Class I Prison Building and Prison Hall Construction Project is appropriate or not by referring to SNI 8459:2017 and the guidebook issued by the Regulations regarding base tests in building structure SNI 03-2847-2013[4]. The method used in this research is a qualitative method, where the data in this research is obtained from direct observation and interviews in the field as primary data and from data testing and data specifications of various secondary data. These two regulations will compare in the field according to the standard which refers to foundation tests on building structures, namely SNI 03-2847-2013 and also refers to SNI 8459:2017 concerning the method of testing deep foundations with High-Strain Dynamic Pile (HSDP) which is where the PDA test is included in the HSDP test. This discussion will focus on testing after the foundation has been worked on in the field.