Dean Mikami
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dean Mikami has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Bradley J. Needleman
Center for Minimally Invasive Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio
4 shared publications - Sabrena Noria
The Ohio State University Wexner Medical Center
3 shared publications - Daniel B. Jones
University of Pittsburgh
2 shared publications Alfons Pomp
Department of Surgery, Weil Cornell Medical College, New York, NY
1 shared publication- Amin Madani
Department of Surgery, University of Toronto, Toronto, Canada
1 shared publication - Anahita Jalilvand
Division of Trauma, Critical Care and Burn, Department of Surgery, Wexner Medical Center, The Ohio State University, Columbus. (A.J.),
1 shared publication
Latest Publications
- 1 May 2025
- Published by SAGE Publications in Bariatric Surgical Practice and Patient Care
- Vol. 20 (2) , 43
Letter from the Editor
- 1 May 2025
- Published by SAGE Publications in Bariatric Surgical Practice and Patient Care
- Vol. 20 (2) , 43
Letter from the Editor
- 1 April 2018
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 14 (4) , 453-461
Endoscopic stent placement for treatment of sleeve gastrectomy leak: a single institution experience with fully covered stents
- 1 April 2018
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 14 (4) , 453-461
Endoscopic stent placement for treatment of sleeve gastrectomy leak: a single institution experience with fully covered stents
- 7 December 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 32 (6) , 2583-2602
The SAGES Fundamental Use of Surgical Energy program (FUSE): history, development, and purpose
Adverse events due to energy device use in surgical operating rooms are a daily occurrence. These occur at a rate of approximately 1–2 per 1000 operations. Hundreds of operating room fires occur each year in the United States, some causing severe injury and even mortality. The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) therefore created the first comprehensive educational curriculum on the safe use of surgical energy devices, called Fundamental Use of Surgical Energy (FUSE). This paper describes the history, development, and purpose of this important training program for all members of the operating room team.
- 7 December 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 32 (6) , 2583-2602
The SAGES Fundamental Use of Surgical Energy program (FUSE): history, development, and purpose
Adverse events due to energy device use in surgical operating rooms are a daily occurrence. These occur at a rate of approximately 1–2 per 1000 operations. Hundreds of operating room fires occur each year in the United States, some causing severe injury and even mortality. The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) therefore created the first comprehensive educational curriculum on the safe use of surgical energy devices, called Fundamental Use of Surgical Energy (FUSE). This paper describes the history, development, and purpose of this important training program for all members of the operating room team.
- Open Access
- 1 November 2016
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 12 (9) , 1737-1745
Impact of care coaching on hospital length of stay, readmission rates, postdischarge phone calls, and patient satisfaction after bariatric surgery
- 1 November 2016
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 12 (9) , 1737-1745
Open AccessImpact of care coaching on hospital length of stay, readmission rates, postdischarge phone calls, and patient satisfaction after bariatric surgery
- Open Access
- 1 September 2014
- Published by Elsevier in Gynecologic Oncology
- Vol. 134 (3) , 540-545
Is bariatric surgery an option for women with gynecologic cancer? Examining weight loss counseling practices and training among gynecologic oncology providers
- 1 September 2014
- Published by Elsevier in Gynecologic Oncology
- Vol. 134 (3) , 540-545
Open AccessIs bariatric surgery an option for women with gynecologic cancer? Examining weight loss counseling practices and training among gynecologic oncology providers
- 1 September 2010
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 6 (5) , 477-482
Effect of staple height on gastrojejunostomy during laparoscopic gastric bypass: a multicenter prospective randomized trial
- 1 September 2010
- Published by Elsevier in Surgery for Obesity and Related Diseases
- Vol. 6 (5) , 477-482
Effect of staple height on gastrojejunostomy during laparoscopic gastric bypass: a multicenter prospective randomized trial
- 1 June 2004
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 14 (3) , 121-124
Initial Experience with the Four-Arm Computer-Enhanced Telesurgery Device in Foregut Surgery
The da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA) has been used effectively and with good results. Previously, the surgeon could manipulate three arms on the robot: one camera port and two working ports. This configuration required a second surgeon for most general surgical procedures. Recently, the robotic device has been modified to include a fourth arm, adding another computer-assisted instrument that the surgeon can manipulate. In this report, we describe our experience with the da Vinci robot with a fourth arm modification for the performance of selected surgical procedures. A total of six patients were prospectively enrolled and underwent surgery using the modified da Vinci robot. Their average age was 56 years. Five patients underwent Nissen fundoplication, and one patient underwent Heller myotomy. Operative time, defined as the time from skin incision to completed skin closure, as well as robotic time, defined as the time during which the robot was being used, were recorded. Intra-operative and perioperative complications were also recorded. Average operative and robotic times for Nissen fundoplication were 134 and 80 minutes, respectively. Operative and robotic times for the Heller myotomy were 118 and 70 minutes. All patients tolerated the procedure well and experienced no perioperative complications. The da Vinci robot with the addition of the fourth arm results in a efficient and safe operation and allows the surgeon to perform additional maneuvers without the use of a surgical assistant.
- 1 June 2004
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 14 (3) , 121-124
Initial Experience with the Four-Arm Computer-Enhanced Telesurgery Device in Foregut Surgery
The da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA) has been used effectively and with good results. Previously, the surgeon could manipulate three arms on the robot: one camera port and two working ports. This configuration required a second surgeon for most general surgical procedures. Recently, the robotic device has been modified to include a fourth arm, adding another computer-assisted instrument that the surgeon can manipulate. In this report, we describe our experience with the da Vinci robot with a fourth arm modification for the performance of selected surgical procedures. A total of six patients were prospectively enrolled and underwent surgery using the modified da Vinci robot. Their average age was 56 years. Five patients underwent Nissen fundoplication, and one patient underwent Heller myotomy. Operative time, defined as the time from skin incision to completed skin closure, as well as robotic time, defined as the time during which the robot was being used, were recorded. Intra-operative and perioperative complications were also recorded. Average operative and robotic times for Nissen fundoplication were 134 and 80 minutes, respectively. Operative and robotic times for the Heller myotomy were 118 and 70 minutes. All patients tolerated the procedure well and experienced no perioperative complications. The da Vinci robot with the addition of the fourth arm results in a efficient and safe operation and allows the surgeon to perform additional maneuvers without the use of a surgical assistant.