Rielly Castle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rielly Castle has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Beatriz D. Moreno
Canadian Light Source, Saskatoon, Canada
1 shared publicationChithra Karunakaran
Canadian Light Source, Saskatoon, Canada
1 shared publicationFeizhou He
Canadian Light Source, Saskatoon, Canada
1 shared publicationJian Wang
Canadian Light Source, Saskatoon, Canada
1 shared publicationMark J. Boland
University of Saskatchewan, Saskatoon, Canada
1 shared publicationNarayan Appathurai
Canadian Light Source, Saskatoon, Canada
1 shared publication
Latest Publications
- Open Access
- 25 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Investigating the limits of hard X-ray coherence length measurement employing Young’s double slit experiment
Young’s double slit experiment has been the most explored technique to gauge a system’s coherence properties. The limits of this technique in characterizing spatial coherence properties of high emittance, hard X-ray synchrotron sources have been performed at the BXDS-IVU beamline, Canadian Light Source (CLS). High emittance synchrotron sources have been assumed to possess sub-optimal coherence properties. While this is largely true, it’s important to understand the limits of coherence for these sources. We demonstrate that the Young’s double slit experiment has harsher limits than what is normally expected. We present data obtained at multiple energies in both spatial directions leading to a thorough understanding of the limitations of employing Young’s double slit experiment to characterize low coherence length systems. We propose a numerical technique to estimate the source size directly from the double slit interference patterns. With these results, we have demonstrated that CLS has functional coherent beam properties in the hard X-ray regime with spatial coherence lengths ranging from 5.37 to 17.61 µm in the horizontal direction. The spatial coherence lengths in the vertical direction were at least 3 times larger. Finally, we present theoretical calculations showcasing the limits of Young’s double slit experiment in characterizing diffraction limited sources.
- 25 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessInvestigating the limits of hard X-ray coherence length measurement employing Young’s double slit experiment
Young’s double slit experiment has been the most explored technique to gauge a system’s coherence properties. The limits of this technique in characterizing spatial coherence properties of high emittance, hard X-ray synchrotron sources have been performed at the BXDS-IVU beamline, Canadian Light Source (CLS). High emittance synchrotron sources have been assumed to possess sub-optimal coherence properties. While this is largely true, it’s important to understand the limits of coherence for these sources. We demonstrate that the Young’s double slit experiment has harsher limits than what is normally expected. We present data obtained at multiple energies in both spatial directions leading to a thorough understanding of the limitations of employing Young’s double slit experiment to characterize low coherence length systems. We propose a numerical technique to estimate the source size directly from the double slit interference patterns. With these results, we have demonstrated that CLS has functional coherent beam properties in the hard X-ray regime with spatial coherence lengths ranging from 5.37 to 17.61 µm in the horizontal direction. The spatial coherence lengths in the vertical direction were at least 3 times larger. Finally, we present theoretical calculations showcasing the limits of Young’s double slit experiment in characterizing diffraction limited sources.