Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Valentin Totev has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Vultchan Gueorgiev

    Technical University of Sofia,Faculty of Electrical Engineering,Sofia,Bulgaria

    17 shared publications
  • Plamen Rizov

    Technical University - Sofia,Faculty of Electrical Engineering,Sofia,Bulgaria

    4 shared publications
  • Dzhengiz Ibram

    Technical University Sofia,Faculty of Electrical Engineering,Sofia,Bulgaria

    2 shared publications
  • Hristo Vasilev

    Technical University of Sofia,Faculty of Electrical Engineering,Sofia,Bulgaria

    2 shared publications
  • Vultchan Gueorgiev

    Department of Electrical Supply, Electrical Equipment and Electrical Transport, Faculty of Electrical Engineering, Technical University of Sofia, 1000 Sofia, Bulgaria

    2 shared publications
  • Dilyan Ivanov

    Department of Electrical Supply, Electrical Equipment and Electrical Transport, Faculty of Electrical Engineering, Technical University of Sofia, 1000 Sofia, Bulgaria

    1 shared publication

Latest Publications

  • Open Access

    Integrated Transcritical CO2 Heat Pump for a Two-Stage Heat Recovery System

    by Vultchan Gueorgiev, Svetoslav Vlashki, Valentin Totev, Ivan Dimchev, Dilyan Ivanov

    Carbon dioxide (CO2/R744) is a natural refrigerant that has been widely studied as a replacement for conventional hydrofluorocarbon-based refrigerants in HVAC&R systems. However, the performance of CO2 heat pumps depends strongly on the system architecture, component parameters, operating conditions, and pressure control. This study examines a CO2-based heat pump integrated into an AHU with two-stage heat recovery. Heat recovery from the exhaust air is initially performed using a regenerative sorption wheel and then in an R744 heat pump with fin-and-tube heat exchangers located directly in the airflows. The operating performance of the heat pump was evaluated through system-level simulation based on commercially available component data and iterative balancing of the refrigeration cycle and air-side processes. For the investigated configuration and selected components, the proposed R744 system is compared with a conventional R410A-based reference system under the same air-side boundary conditions. Therefore, this comparison is interpreted as a system-level benchmark rather than an isolated effect of the refrigerant itself, since performance depends on the refrigerant’s properties, compressor performance, heat exchanger configuration, system architecture, and the operating limitations of the components. Simulations are performed for both heating and cooling modes, while preliminary experimental measurements from a physical prototype are presented for qualitative comparison with the simulated heating-mode trend.

  • An Analysis of the Feasibility of Renewable Energy Sources to Supply Thermal Loads

    by Valentin Totev, Vultchan Gueorgiev, Hristo Vasilev

    An analysis of the feasibility of renewable energy sources (RES) to supply thermal loads is performed in this paper. Additionally, the possibility to return hot water in district heating (DH) system is explored. The object of the analysis is a large swimming pool and considered RES are solar collectors (SCs), photovoltaics (PVs) and photovoltaic thermal (PVTs). Based on a techno-economic assessment the following conclusions can be drawn - PVs have the lowest payback period, SCs exhibit the best efficiency to capital cost ratio. However, with current state of PVs, their low price can easily push oneself towards investing in increasing the overall PV capacity and also in battery storage systems. PVTs are an emerging technology that has yet to prove itself. Unfortunately, it is inexpedient to return hot water in the DH system, as this is bound to increase water losses drastically.

  • Open Access

    Evaluating Cybersecurity Risks of Bulgaria’s Energy Sector: Focus on PV and HVAC-R

    by Vultchan Gueorgiev, Valentin Totev, Plamen Tsankov, Stoyan Stoyanov

    Photovoltaics with energy storage are the current trend in solar energy. Hybrid inverters are the backbone of low-power installations of this type. If a single installation is compromised, there are no significant security concerns. However, multiple devices can be targeted simultaneously. Taking into account their increasing share in the energy mix, distributed cyber-attacks against these devices can threaten grid stability. The Bulgarian electric power system has been analyzed in order to determine its development which is in line with EU-wide trends. It can be concluded that hybrid inverters are expected to grow rapidly in number and in installed power. The vulnerability of hybrid inverters to cyber-attacks has been analyzed, and the possible consequences for the energy system have been identified. The technology allows it to be used as a hybrid means of influence, and this aspect is poorly addressed in existing cybersecurity regulations. A risk assessment has been made, based on which measures to improve security have been proposed.

  • Modelling of Supercapacitors in EVs

    by Valentin Totev

    Supercapacitors (SCs) are still considered as emerging storage devices. However, the combined operation of $SC s$ and Li-ion batteries, forming hybrid energy storage systems (HESS), has shown real world feasibility, especially in electrified transportation. Thus, this paper is purposed to propose a simple small-scale model of a $SC$ in $EV$ 's drivetrain system. Two scenarios are considered - $SC$ replacing Li-ion battery as the first scenario and the second scenario consisting of including $SC$ in tandem with Li-ion battery (HESS). Obtained results are as expected, i.e. $SC_{S}$ being less inert than batteries react faster to the transients whenever regenerative braking occurs.

  • Phase Failures During Starting of High Power In-House Loads

    by Valentin Totev, Vultchan Gueorgiev

    The operation of sections of in-house loads and auxiliary equipment of a Bulgarian power station in fault conditions during starting procedures that take place after completion of planned annual repairment is studied. The considered fault conditions are single-phase open circuit, double-phase open circuit and single-phase open circuit with earth fault. During starting procedures sections are not fully loaded. Based on results it can be seen that imbalances caused by phase failures and open circuit faults during starting are practically similar as whenever they are fully loaded. Thus, the respective protection devices trip accordingly.

  • High Voltage Faults Conditions of In-House Loads of a Power Station

    by Valentin Totev, Plamen Rizov, Vultchan Gueorgiev

    Open circuit conditions which are not trivial to accurately locate can be detrimental to the operation of auxiliary equipment and in-house loads of a power station. Previously, the behaviour of the sections of auxiliary equipment and in-house loads, supplied through main and backup transformers, under influence of such faults on buses 220, 24 and 6 kV was studied. Thus, the purpose of this paper is to study these faults on 400 kV. Albeit the observed voltages' and currents' deformations and imbalances, selectivity of protection devices is not violated.

  • Modelling of Own Needs' Equipment During Faults

    by Valentin Totev, Dzhengiz Ibram, Plamen Rizov, Vultchan Gueorgiev

    The behaviour of a power station's own needs' power equipment during open circuit fault conditions is modelled and presented in this paper. The considered situation is with reduced loads on own needs' sections. Based on obtained results it can be concluded that albeit the caused significant imbalances, there is always at least one faulty phase current of own needs' power equipment that trips protection accordingly.


  • A Study on the Operation of Own Needs' Equipment Under Fault Conditions

    by Valentin Totev, Dzhengiz Ibram, Plamen Rizov, Vultchan Gueorgiev

    A study on the operating regimes of own needs' power equipment under fault conditions has been performed. The purpose of the study is to investigate the operation of own needs' power equipment on medium voltage 6 kV (motors and transformers) under fault conditions. The following fault conditions are studied - single-phase open circuit, double-phase open circuit and single-phase open circuit with earth fault. Based on obtained results only own needs' transformers (6/0.4 kV) operate with asymmetrical currents which values do not exceed their respective protection thresholds. With regards to own needs' motors there is always at least one current value that exceeds set protection threshold.


  • Hybrid Energy Storage System To Increase Energy Efficiency During Regenerative Braking Of Urban Electrical Transport

    by Valentin Totev, Hristo Vasilev, Vultchan Gueorgiev, Ivan Angelov

    A case study on the possibilities to increase energy efficiency during regenerative braking of public urban electrical transport (PUET) of Sofia by utilization of hybrid energy storage system (HESS), comprised primarily of supercapacitors, is presented in this paper. A HESS can be applied to increase energy savings and efficiency, and improve power quality. With the utilization of HESS during regenerative braking the energy can be stored and to be extracted afterwards back into the overhead catenary to supply travelling PUET vehicles. The utilization of supercapacitors as on-board storage devices has been proven on electrical buses. However, in the case of trolleybuses and trams it is not the case which presents the question of installing HESS in substations. In addition, the potential of utilizing photovoltaic (PV) installations to further reduce costs is explored. Based on obtained results regenerative braking is primarily occurring during a full stop and less whenever descending. Thus, the estimated energy capacity that is meaningful to be stored in HESS is rather small. Furthermore, estimated utilization of PV's can reduce energy costs by up to 13 %. Nevertheless, increasing efficiency of public transport is beneficial to society itself and cannot be compared to an economic profit.