BHBenedikt Hauer

Benedikt Hauer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Benedikt Hauer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prediction of oxide coating thickness on moving polymer films using quantum cascade laser spectroscopy and machine learning

    by Friederike Rita Petra Münch, Benedikt Hauer, Yuri Victorovich Flores, Marko Haertelt, Ingo Breunig, Daniel Carl

    Nanometer-accurate inline monitoring of oxide coating thickness on polymer films is essential for quality control in roll-to-roll production. However, measuring coatings in the nanometer range on moving polymer films remains challenging because the measurement samples spatially varying polymer thickness and reflective background conditions along the measurement path, in addition to the low optical contrast between oxide and polymer in the mid-infrared. We present a transflection measurement approach that combines quantum cascade laser (QCL) spectroscopy with data-driven spectral analysis. We apply it to moving oriented polypropylene (OPP) and polyethylene terephthalate (PET) films coated with silicon oxide under laboratory conditions to assess its feasibility for future inline monitoring. In transflection mode, reflected intensity is captured across a spectral range covering the Si–O absorption band, enabling measurements on both transparent and opaque films. Two spectral analysis approaches are proposed and compared. The first combines spectral averaging with linear regression, achieving a mean root mean square error (RMSE) of 7.6 nm for OPP and 15.9 nm for PET. The second combines linear regression and Gaussian process regression (LR-GPR) on blockwise-aggregated spectra. For thickness levels represented in the training data, this approach reduces the RMSE to approximately 4nm for both OPP and PET, corresponding to improvements of approximately 50% for OPP and 75% for PET. While the former approach offers simplicity and interpretability, the latter captures nonlinear spectral relationships. However, generalization of LR-GPR to unseen thickness levels remains the central limitation, with RMSE values of approximately 10 nm to 11 nm. The results show potential for oxide coating thickness estimation, while improved generalization and further validation are needed to establish broader applicability.

  • Open Access

    Bringing Attomolar Detection to the Point‐of‐Care with Nanopatterned DNA Origami Nanoantennas

    by Renukka Yaadav, Kateryna Trofymchuk, Mihir Dass, Vivien Behrendt, Benedikt Hauer, Jan Schütz, Cindy Close, Michael Scheckenbach, Giovanni Ferrari, Leoni Mäurer, et al.

    Creating increasingly sensitive and cost‐effective nucleic acid detection methods is critical for enhancing point‐of‐care (POC) applications. This requires highly specific capture of biomarkers and efficient transduction of capture events. However, the signal from biomarkers present at extremely low amounts often falls below the detection limit of typical fluorescence‐based methods, necessitating molecular amplification. Here, we present single‐molecule detection of a non‐amplified, 151‐nucleotide sequence specific to antibiotics‐resistant Klebsiella pneumoniae down to attomolar concentrations, using Trident NanoAntennas with Cleared HOtSpots (NACHOS). This NACHOS‐diagnostics assay leverages a compact microscope with a large field‐of‐view, including microfluidic flow to enhance capturing efficiency. Fluorescence enhancement is provided by NanoAntennas, arranged using a combination of nanosphere lithography and site‐specific DNA origami placement. This method can detect 200 ± 50 out of 600 molecules in a 100 µL sample volume within an hour. This represents a typical number of pathogens in clinical samples commonly detected by Polymerase Chain Reaction. We achieve similar sensitivity in untreated human plasma, enhancing the practical applicability of the system. This platform can be adapted to detect shorter nucleic acid fragments that are not compatible with traditional amplification‐based technologies. This provides a robust and scalable solution for sensitive nucleic acid detection in diverse clinical settings.


  • Open Access

    Multi-Angle Averaging Approach for Measuring the Coating Thickness on Thin Transparent Polymer Films

    by Friederike Münch, Benedikt Hauer, Ingo Breunig, Daniel Carl

    Polymer films with a thickness in the two-digit micrometer range are coated with nanometer-thin oxide layers in roll-to-roll coating systems. The coating improves the properties of the film, such as gas or water permeation. Maintaining a sufficiently large coating thickness is crucial to ensure its barrier function; thus, inline quality control of the thickness is indispensable. For this purpose, we have developed a sensing principle that addresses specific absorption bands of the coating via a reflection measurement in the infrared spectral range. However, for thin and weakly absorbing polymer substrates, light is reflected not only by the coating and the surface of the polymer. Partly it is also transmitted and reflected by the backside of the film, leading to interference effects that significantly affect the measurement signal. As industrial films vary in thickness by several percent and their exact values are unknown, determining the thickness of an oxide coating is hindered. In this paper, we demonstrate an approach for measuring coating thickness on such varying polymer films by averaging the interferences obtained at multiple angles of incidence. Calculations and measurements on industrial film samples indicate the effectiveness of our approach. It produces results with ± 2 nm precision and ± 5 nm accuracy for a thickness in the range of 5–100 nm. Furthermore, we discuss a possible implementation of this approach in an inline measurement system by fulfilling its requirements, for example, versatility and compactness.