Shasha Xu
Research Subjects
Shasha Xu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Wei Li
SINO-SINA Building Materials Co., Ltd., Zhengzhou 452370, China
2 shared publications - Hongke Ma
School of Civil Engineering, Zhengzhou University, Zhengzhou 450001, China
1 shared publication - Hongze Zhang
SINO-SINA Building Materials Co., Ltd., Zhengzhou 452370, China
1 shared publication - Hui Jiang
SINO-SINA Building Materials Co., Ltd., Zhengzhou 452370, China
1 shared publication - Jiahao Hu
Department of Civil Engineering, Zhengzhou University, Zhengzhou 450001, China
1 shared publication - Ju Liu
SINO-SINA Building Materials Co., Ltd., Zhengzhou 452370, China
1 shared publication
Latest Publications
- Open Access
Flexural Capacity Calculation Method for Pre-Damaged RC Beam–Column Joints Strengthened with High-Strength Steel Strand Mesh-Reinforced ECC
Pre-existing damage in reinforced concrete (RC) beam–column joints may induce strain incompatibility between the original member and subsequently applied strengthening layers, limiting the applicability of conventional flexural-capacity models. This study experimentally and analytically investigates pre-damaged RC beam–column joints strengthened with high-strength steel strand wire mesh-reinforced engineered cementitious composite (HSSWM–ECC). Eight specimens were tested to evaluate the effects of pre-damage level, steel strand spacing, and axial compression ratio on beam-end flexural behavior. HSSWM–ECC effectively suppressed crack localization and concrete spalling, and all strengthened specimens ultimately exhibited beam-end flexural failure while the columns and joint cores remained largely intact. Compared with the unstrengthened specimen, the peak load increased by 39.24–63.88%. Reducing the strand spacing from 70 to 30 mm increased the peak load by 8.86%, whereas the higher pre-damage level caused an 11.28% reduction relative to the undamaged strengthened specimen. Within the investigated axial compression ratio range of 0.2–0.4, the difference in peak load remained below 3.64%, whereas increasing axial compression was associated with more pronounced post-peak strength degradation. Based on sectional force equilibrium and the plane-section assumption, an analytical model was developed by incorporating damage-induced strain lag and the contribution of the wrap-around side strengthening layers. The predicted capacities of the seven strengthened specimens agreed well with the experimental results, with deviations within 7%. The proposed model provides a rational approach for evaluating the beam-end flexural capacity of pre-damaged RC beam–column joints strengthened with HSSWM–ECC within the investigated parameter range and flexure-dominated failure mode.
Open AccessFlexural Capacity Calculation Method for Pre-Damaged RC Beam–Column Joints Strengthened with High-Strength Steel Strand Mesh-Reinforced ECC
Pre-existing damage in reinforced concrete (RC) beam–column joints may induce strain incompatibility between the original member and subsequently applied strengthening layers, limiting the applicability of conventional flexural-capacity models. This study experimentally and analytically investigates pre-damaged RC beam–column joints strengthened with high-strength steel strand wire mesh-reinforced engineered cementitious composite (HSSWM–ECC). Eight specimens were tested to evaluate the effects of pre-damage level, steel strand spacing, and axial compression ratio on beam-end flexural behavior. HSSWM–ECC effectively suppressed crack localization and concrete spalling, and all strengthened specimens ultimately exhibited beam-end flexural failure while the columns and joint cores remained largely intact. Compared with the unstrengthened specimen, the peak load increased by 39.24–63.88%. Reducing the strand spacing from 70 to 30 mm increased the peak load by 8.86%, whereas the higher pre-damage level caused an 11.28% reduction relative to the undamaged strengthened specimen. Within the investigated axial compression ratio range of 0.2–0.4, the difference in peak load remained below 3.64%, whereas increasing axial compression was associated with more pronounced post-peak strength degradation. Based on sectional force equilibrium and the plane-section assumption, an analytical model was developed by incorporating damage-induced strain lag and the contribution of the wrap-around side strengthening layers. The predicted capacities of the seven strengthened specimens agreed well with the experimental results, with deviations within 7%. The proposed model provides a rational approach for evaluating the beam-end flexural capacity of pre-damaged RC beam–column joints strengthened with HSSWM–ECC within the investigated parameter range and flexure-dominated failure mode.
- Open Access
The Mechanical Properties and Durability of the PE-BFRP Hybrid-Fiber-Engineered Cementitious Composite (ECC)
This paper investigates the effects of the basalt-fiber-reinforced polymer (BFRP) and polyethylene (PE) hybrid fiber ratio on the mechanical properties and durability of engineered cementitious composites (ECC). First, four different PE-BFRP hybrid fiber ECC mixtures were systematically prepared by controlling the fiber volume ratio of PE and BFRP fibers. The workability and mechanical properties of the hybrid fiber ECC (HFECC) were then evaluated using flowability tests and multi-scale mechanical tests, including compressive strength, flexural strength, bending toughness, and tensile performance. After that, the durability of HFECC with different fiber ratios was comprehensively assessed through freeze–thaw cycle tests and rapid ion migration tests. Finally, the interface morphology of fibers within the matrix was observed using scanning electron microscopy (SEM). The results show that an appropriate hybrid of PE and BFRP fibers can synergistically enhance the crack resistance and toughness of ECC, improving its failure mode. The best performance in terms of flowability and mechanical properties was observed for the HFECC mixture with 1.30% PE fiber volume and 0.30% BFRP fiber volume. With the increase in BFRP fiber content, the freeze–thaw resistance and chloride ion erosion resistance of HFECC were gradually enhanced. This study provides experimental and theoretical support for the design and engineering application of high-performance hybrid fiber ECC materials.
Open AccessThe Mechanical Properties and Durability of the PE-BFRP Hybrid-Fiber-Engineered Cementitious Composite (ECC)
This paper investigates the effects of the basalt-fiber-reinforced polymer (BFRP) and polyethylene (PE) hybrid fiber ratio on the mechanical properties and durability of engineered cementitious composites (ECC). First, four different PE-BFRP hybrid fiber ECC mixtures were systematically prepared by controlling the fiber volume ratio of PE and BFRP fibers. The workability and mechanical properties of the hybrid fiber ECC (HFECC) were then evaluated using flowability tests and multi-scale mechanical tests, including compressive strength, flexural strength, bending toughness, and tensile performance. After that, the durability of HFECC with different fiber ratios was comprehensively assessed through freeze–thaw cycle tests and rapid ion migration tests. Finally, the interface morphology of fibers within the matrix was observed using scanning electron microscopy (SEM). The results show that an appropriate hybrid of PE and BFRP fibers can synergistically enhance the crack resistance and toughness of ECC, improving its failure mode. The best performance in terms of flowability and mechanical properties was observed for the HFECC mixture with 1.30% PE fiber volume and 0.30% BFRP fiber volume. With the increase in BFRP fiber content, the freeze–thaw resistance and chloride ion erosion resistance of HFECC were gradually enhanced. This study provides experimental and theoretical support for the design and engineering application of high-performance hybrid fiber ECC materials.