AWAdi Wijaya

Adi Wijaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adi Wijaya has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diabetic Retinopathy Detection Based on Convolutional Neural Networks with SMOTE and CLAHE Techniques Applied to Fundus Images

    by Sidhiq Mardianta, Affandy Affandy, Catur Supriyanto, Adi Wijaya

    Diabetic retinopathy (DR) is one of the major complications in diabetic patients' eyes, potentially leading to permanent blindness if not detected timely. This study aims to evaluate the accuracy of artificial intelligence (AI) in diagnosing DR. The method employed is the Synthetic Minority Over-sampling Technique (SMOTE) algorithm, applied to identify DR and its severity stages from fundus images using the public dataset "APTOS 2019 Blindness Detection." Literature was reviewed via ScienceDirect, ResearchGate, Google Scholar, and IEEE Xplore. Classification results using Convolutional Neural Network (CNN) showed the best performance for the binary classes normal (0) and DR (1) with an accuracy of 99.55%, precision of 99.54%, recall of 99.54%, and F1-score of 99.54%. For the multiclass classification No_DR (0), Mild (1), Moderate (2), Severe (3), Proliferate_DR (4), the accuracy was 95.26%, precision 95.26%, recall 95.17%, and F1-score 95.23%. Evaluation using the confusion matrix yielded results of 99.68% for binary classification and 96.65% for multiclass. This study highlights the significant potential in enhancing the accuracy of DR diagnosis compared to traditional human analysis


  • Open Access

    Narrow Window Feature Extraction for EEG-Motor Imagery Classification using k-NN and Voting Scheme

    by Adi Wijaya, Teguh Bharata Adji, Noor Akhmad Setiawan

    Achieving consistent accuracy still big challenge in EEG based Motor Imagery classification since the nature of EEG signal is non-stationary, intra-subject and inter-subject dependent. To address this problems, we propose the feature extraction scheme employing statistical measurements in narrow window with channel instantiation approach. In this study, k-Nearest Neighbor is used and a voting scheme as final decision where the most detection in certain class will be a winner. In this channel instantiation scheme, where EEG channel become instance or record, seventeen EEG channels with motor related activity is used to reduce from 118 channels. We investigate five narrow windows combination in the proposed methods, i.e.: one, two, three, four and five windows. BCI competition III Dataset IVa is used to evaluate our proposed methods. Experimental results show that one window with all channel and a combination of five windows with reduced channel outperform all prior research with highest accuracy and lowest standard deviation. This results indicate that our proposed methods achieve consistent accuracy and promising for reliable BCI systems.

  • Open Access

    Narrow Window Feature Extraction for EEG-Motor Imagery Classification using k-NN and Voting Scheme

    by Adi Wijaya, Teguh Bharata Adji, Noor Akhmad Setiawan

    Achieving consistent accuracy still big challenge in EEG based Motor Imagery classification since the nature of EEG signal is non-stationary, intra-subject and inter-subject dependent. To address this problems, we propose the feature extraction scheme employing statistical measurements in narrow window with channel instantiation approach. In this study, k-Nearest Neighbor is used and a voting scheme as final decision where the most detection in certain class will be a winner. In this channel instantiation scheme, where EEG channel become instance or record, seventeen EEG channels with motor related activity is used to reduce from 118 channels. We investigate five narrow windows combination in the proposed methods, i.e.: one, two, three, four and five windows. BCI competition III Dataset IVa is used to evaluate our proposed methods. Experimental results show that one window with all channel and a combination of five windows with reduced channel outperform all prior research with highest accuracy and lowest standard deviation. This results indicate that our proposed methods achieve consistent accuracy and promising for reliable BCI systems.