Liqun Guan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liqun Guan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mark Dewsbury
School of Architecture and Design, University of Tasmania, Launceston, TAS 7250, Australia
9 shared publications - Hartwig Künzel
Fraunhofer Institute for Building Physics IBP, 83626 Valley, Germany
7 shared publications - Louise Wallis
School of Architecture and Design, University of Tasmania, Launceston, TAS 7250, Australia
6 shared publications Mark Dewsbury
4 shared publicationsFreya Su
3 shared publicationsLouise Wallis
3 shared publications
Latest Publications
- Open Access
- 5 May 2026
- Published by Elsevier in Building and Environment
- Vol. 299
An evaluation of hygrothermal risks associated with intermittent conditioning in energy-efficient Australian homes
- 5 May 2026
- Published by Elsevier in Building and Environment
- Vol. 299
Open AccessAn evaluation of hygrothermal risks associated with intermittent conditioning in energy-efficient Australian homes
- Open Access
- 28 March 2026
- Published by Elsevier in Energy and Buildings
- Vol. 360
Investigating the effects of intermittent indoor temperature control on hygrothermal risks in energy-efficient homes
- 28 March 2026
- Published by Elsevier in Energy and Buildings
- Vol. 360
Open AccessInvestigating the effects of intermittent indoor temperature control on hygrothermal risks in energy-efficient homes
- Open Access
- 23 January 2026
- Published by UCL Press in UCL Open Environment
- Vol. 8 (1)
Relative humidity in intermittently conditioned energy‑efficient homes: a preliminary hygrothermal assessment of indoor condensation and mould risk
Rising global temperatures and increasing energy demand have led to more stringent energy efficiency requirements in buildings. While these measures reduce energy use, they may unintentionally increase the risk of indoor and interstitial moisture accumulation and mould growth. Highly insulated and airtight dwellings, combined with occupant-controlled ventilation and intermittent space conditioning without relative humidity regulation, can create environments conducive to mould, threatening indoor air quality, occupant health and building durability. In Australia, the 2022 National Construction Code mandates a minimum 7-star building envelope focused energy rating for new residential dwellings. Unlike international standards, Australian regulations include intermittent conditioning without specifying indoor relative humidity limits, potentially increasing moisture-related risks. This study examines the effects of intermittently conditioned indoor climate on interstitial moisture accumulation and mould growth in two of the most common low-rise timber-framed wall systems: clay masonry veneer and compressed fibre cement sheet cladding within temperate Australian climate zones. Ten-year transient hygrothermal simulations were conducted to quantify moisture and mould risks. Results show, without relative humidity control, indoor conditions frequently exceed the internationally recommended 70% relative humidity threshold, significantly increasing interstitial mould risk, particularly in bedrooms and open-plan living space. Comparisons with continuous conditioning, per the American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 160, indicate lower risks under continuous conditions. Mitigation strategies, including ventilated cavities and internal vapour control layer, were effective under continuous conditioning but exhibited inconsistent performance under conditions of unregulated relative humidity in intermittent conditioning. The findings reveal the limitations of continuous conditioning assumptions for moisture control design and underscore the problem of underestimating moisture risks in buildings.
- 23 January 2026
- Published by UCL Press in UCL Open Environment
- Vol. 8 (1)
Open AccessRelative humidity in intermittently conditioned energy‑efficient homes: a preliminary hygrothermal assessment of indoor condensation and mould risk
Rising global temperatures and increasing energy demand have led to more stringent energy efficiency requirements in buildings. While these measures reduce energy use, they may unintentionally increase the risk of indoor and interstitial moisture accumulation and mould growth. Highly insulated and airtight dwellings, combined with occupant-controlled ventilation and intermittent space conditioning without relative humidity regulation, can create environments conducive to mould, threatening indoor air quality, occupant health and building durability. In Australia, the 2022 National Construction Code mandates a minimum 7-star building envelope focused energy rating for new residential dwellings. Unlike international standards, Australian regulations include intermittent conditioning without specifying indoor relative humidity limits, potentially increasing moisture-related risks. This study examines the effects of intermittently conditioned indoor climate on interstitial moisture accumulation and mould growth in two of the most common low-rise timber-framed wall systems: clay masonry veneer and compressed fibre cement sheet cladding within temperate Australian climate zones. Ten-year transient hygrothermal simulations were conducted to quantify moisture and mould risks. Results show, without relative humidity control, indoor conditions frequently exceed the internationally recommended 70% relative humidity threshold, significantly increasing interstitial mould risk, particularly in bedrooms and open-plan living space. Comparisons with continuous conditioning, per the American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 160, indicate lower risks under continuous conditions. Mitigation strategies, including ventilated cavities and internal vapour control layer, were effective under continuous conditioning but exhibited inconsistent performance under conditions of unregulated relative humidity in intermittent conditioning. The findings reveal the limitations of continuous conditioning assumptions for moisture control design and underscore the problem of underestimating moisture risks in buildings.
- 3 December 2025
- Published by Architectural Science Association
Assessing Indoor Climate and Mould Risks in Energy-Efficient Australian New Homes: A Comparison of AIRAH DA07 Continuous and Intermittent Conditioning Approaches
Https://doi.org/10.65388/HRVP8201 Energy-efficient building design has emerged as a key strategy in addressing the global climate crisis. However, growing evidence suggests that such buildings can reduce indoor climate resilience, particularly due to interstitial moisture accumulation and mould growth. Transient hygrothermal and bio-hygrothermal simulations can inform building envelope design to mitigate moisture and mould related risks....
- 3 December 2025
- Published by Architectural Science Association
Assessing Indoor Climate and Mould Risks in Energy-Efficient Australian New Homes: A Comparison of AIRAH DA07 Continuous and Intermittent Conditioning Approaches
Https://doi.org/10.65388/HRVP8201 Energy-efficient building design has emerged as a key strategy in addressing the global climate crisis. However, growing evidence suggests that such buildings can reduce indoor climate resilience, particularly due to interstitial moisture accumulation and mould growth. Transient hygrothermal and bio-hygrothermal simulations can inform building envelope design to mitigate moisture and mould related risks....
- 23 October 2025
- Published by Springer Nature
- p. 342-355
Moisture and Mould Challenges Within Low-Rise Timber-Framed Residential Wall Systems in Temperate Climates
- 23 October 2025
- Published by Springer Nature
- p. 342-355
Moisture and Mould Challenges Within Low-Rise Timber-Framed Residential Wall Systems in Temperate Climates
- 23 October 2025
- Published by Springer Nature
- p. 170-185
The Impact of Uncontrolled Relative Humidity on Mould Growth Within Timber-Framed Low-Rise External Wall Systems in Temperate Climates
- 23 October 2025
- Published by Springer Nature
- p. 170-185
The Impact of Uncontrolled Relative Humidity on Mould Growth Within Timber-Framed Low-Rise External Wall Systems in Temperate Climates
- Open Access
Navigating Energy Efficiency and Mould Risk in Australian Low-Rise Homes: A Comparative Analysis of Nine External Wall Systems in Southeast Australia
As energy-efficient buildings become central to climate change mitigation, the opportunity for interior and interstitial moisture accumulation and mould growth can increase. This study investigated the potential simulation-based mould growth risks associated with the current generation of insulated low-rise timber framed external wall systems within southeastern Australia. More than 8000 hygrothermal and bio-hygrothermal simulations were completed to evaluate seasonal moisture patterns and calculate mould growth potential for nine typical external wall systems. Results reveal that the combination of increased thermal insulation and air-tightness measures between the 2010 and 2022 specified building envelope energy efficiency regulations further increased predicted Mould Index values, particularly in cool-temperate climates. This was in part due to insufficient moisture management requirements, like an air space between the cladding and the weather resistive layer and/or the low-water vapour permeability of exterior weather resistive pliable membranes. By contrast, warmer temperate climates and drier cool-temperate climates exhibit consistently lower calculated Mould Index values. Despite the 2022 requirement for a greater water vapour-permeance of exterior pliable membranes, the external walls systems explored in this research had a higher calculated Mould Index than the 2010 regulatory compliant external wall systems. Lower air change rates significantly increased calculated interstitial mould growth risk, while the use of interior vapour control membranes proved effective in its mitigation for most external wall systems. The addition of ventilated cavity in combination with either or both an interior vapour control membrane and a highly vapour-permeable exterior pliable membranes further reduced risk. The findings underscore the need for tailored, climate-responsive design interventions to minimise surface and interstitial mould growth risk and building durability, whilst achieving high performance external wall systems.
Open AccessNavigating Energy Efficiency and Mould Risk in Australian Low-Rise Homes: A Comparative Analysis of Nine External Wall Systems in Southeast Australia
As energy-efficient buildings become central to climate change mitigation, the opportunity for interior and interstitial moisture accumulation and mould growth can increase. This study investigated the potential simulation-based mould growth risks associated with the current generation of insulated low-rise timber framed external wall systems within southeastern Australia. More than 8000 hygrothermal and bio-hygrothermal simulations were completed to evaluate seasonal moisture patterns and calculate mould growth potential for nine typical external wall systems. Results reveal that the combination of increased thermal insulation and air-tightness measures between the 2010 and 2022 specified building envelope energy efficiency regulations further increased predicted Mould Index values, particularly in cool-temperate climates. This was in part due to insufficient moisture management requirements, like an air space between the cladding and the weather resistive layer and/or the low-water vapour permeability of exterior weather resistive pliable membranes. By contrast, warmer temperate climates and drier cool-temperate climates exhibit consistently lower calculated Mould Index values. Despite the 2022 requirement for a greater water vapour-permeance of exterior pliable membranes, the external walls systems explored in this research had a higher calculated Mould Index than the 2010 regulatory compliant external wall systems. Lower air change rates significantly increased calculated interstitial mould growth risk, while the use of interior vapour control membranes proved effective in its mitigation for most external wall systems. The addition of ventilated cavity in combination with either or both an interior vapour control membrane and a highly vapour-permeable exterior pliable membranes further reduced risk. The findings underscore the need for tailored, climate-responsive design interventions to minimise surface and interstitial mould growth risk and building durability, whilst achieving high performance external wall systems.