RQRui-Qi Qiao

Rui-Qi Qiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rui-Qi Qiao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The results of anterior cruciate ligament reconstruction with allograft versus autograft: a systematic review and meta-analysis

    by Shilong Zhu, Rongxing Ma, Ruiqi Qiao, Jingyu Zhang, Yongcheng Hu

    Purpose Anterior cruciate ligament (ACL) injury is a common sports-related injury that often requires surgical intervention. The two main types of grafts used in ACL reconstruction are autografts and allografts. Two types of transplants have their own advantages in different aspects, so the choice of graft type is a matter of ongoing debate among orthopedic surgeons. The purpose of this systematic review and meta-analysis is to compare the results of ACL reconstruction using allograft versus autograft. Methods The Embase and PubMed databases were searched for clinical trial literature from January 1, 2000, to July 19, 2023, which met the individual inclusion criteria, for a meta-analysis of objective and subjective outcomes of the knee joint. Using random effects model, risk of bias was assessed using the Cochrane Collaboration’s tools. Results Thirteen studies and total of 1299 patients were included in the analysis. The pooled mean difference (MD) of subjective IKDC score was 2.14 (95% CI:1.43–2.85). The pooled MD of Lysholm score was 0.38 (95% CI:–1.25–2.02). The pooled MD of Tegner score was 0.23 (95% CI:0.03–0.43). The pooled relative risk (RR) of Lachman test was 1.32 (95% CI:0.95–1.82). The pooled RR of pivot shift test was 1.12 (95% CI:1.00–1.25). The pooled RR of objective IKDC was 1.03 (95% CI:1.01–1.05). In general, statistically significant differences in favor of autograft were observed for Subjective International Knee Documentation Committee score, Tegner score, pivot shift test and Objective International Knee Documentation Committee score, as for the Lysholm score and Lachman test there is no statistical differences between the two. Conclusion From a majority of the outcome measures, autografts appear to have a slightly better effect compared to allografts. However, these slight differences in scores may not be reflected in clinical outcomes, indicating that there is not much superiority or inferiority between the two from the perspective of clinical outcomes. Therefore, in other fields such as humanities and economics, they are important factors for doctors to make choices in clinical practice.


  • Open Access

    Design and Practical Application of a Waveform Cryogenic Clamp: Innovation in Low-temperature Control and Tendon Biomechanics

    by Zhi-Tao Xie, Li-Min Wang, Deng-Xing Lun, Hong-Yu Wang, Rui-Qi Qiao, Jing-Yu Zhang, Yong-Cheng Hu

    This study innovatively developed a waveform cryogenic clamp to address issues like insufficient low - temperature maintenance, slippage, and structural damage in connective tissue biomechanical testing. The cooling efficiency of the clamp was comprehensively evaluated by comparing quenching and unilateral cooling methods. The quenching method maintained the average temperature of the clamp jaws at -35.0℃ to -46.0℃ for 5–6 minutes after liquid nitrogen removal, with significant temperature differences between fixed and movable jew plates. The tendon at 1 cm from the upper and lower clamp jaws cooled to -138.3℃ and − 135.8℃, while those 2 cm away reached − 85.7℃ and − 74.0℃, consuming 480 mL of liquid nitrogen per cycle. The unilateral cooling method, with intermittent liquid nitrogen injections into the coolant reservoirs of the upper and lower clamps, maintained the average temperature of the clamp jaws at -35℃ to -40℃ for 5 minutes, with tendons 1 cm away cooling to -1.2℃ and − 1.1℃, and those 2 cm away reaching 13.5℃ and 14.0℃, consuming 600 mL of liquid nitrogen per cycle. The waveform cryogenic clamp showed no tendon slippage and increased rupture frequency and severity, with ruptures predominantly occurring in the central tendon region, achieving an average ultimate load of 2075.900 ± 286.682 N and an average maximum stress of 140.569 ± 25.157 MPa. Despite longer cooling time and higher liquid nitrogen consumption, the unilateral cooling method provided more uniform temperature distribution and reduced tendon damage near the clamp ends. The waveform cryogenic clamp, with its unique waveform structure, low-temperature cooling mechanism, and rotary screw design demonstrated advantages such as superior low-temperature control, high clamping force, low cost, and reliability, adaptable to various experimental scenarios.