Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ayub Alam has a total of 67 co-authors. Here are the top co-authors by number of shared publications:

  • Batool Fatima

    Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan

    6 shared publications
  • Dilshad Hussain

    HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi, Karachi, 75270, Pakistan

    6 shared publications
  • Muhammad Najam-Ul-Haq

    Institute of Chemical Sciences, Bahauddin Zakariya University, Multan, 60800, Pakistan

    5 shared publications
  • Iqra Iqbal

    Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan

    4 shared publications
  • Faiqa Gull

    Department of Biochemistry Bahauddin Zakariya University Multan Pakistan

    3 shared publications
  • Sana Younis

    The Institute of Chemistry University of Graz Graz Austria

    3 shared publications

Latest Publications

  • Open Access

    Wearable Organic Electrochemical Transistor Biosensor for Real-Time Measurement of Sweat Salinity and Saturation

    by Francesco Gentile, Edmondo Battista, Daniela Cardone, David Perpetuini, Teresa Paolucci, Mirko Pesce, Ayub Alam, Valentina Vit, Luigi Bruno, Arcangelo Merla, et al.

    Wearable sweat sensing offers a noninvasive strategy for continuous monitoring of hydration, electrolyte balance, and physiological stress. Here, we demonstrate a flexible textile-based organic electrochemical transistor (OECT) biosensor for real-time quantification of sweat salinity and saturation during physical activity. The device consists of cotton fibers functionalized with the conductive polymer PEDOT:PSS, configured as channel and gate electrodes within a biocompatible patch. The gate and drain currents measured by the device in response to sweat are decoded using a mathematical model that estimates both the total salt concentration and the sweat saturation level. Unlike conventional enzymatic or membrane-based sensors, the platform operates without selective coatings, improving robustness, reproducibility, and mechanical stability. In in vitro tests, the device exhibited a linear response in the 10–4 M–1 M concentration range, a limit of detection as low as 10-5 M, and a response time below 40 s. Moreover, the sensor device was validated in three participants during treadmill running sessions lasting up to 1 h. The saturation profiles derived from the sensor showed a very high correlation with facial skin temperature measured by infrared thermography in all participants (up to 0.90), and with heart rate variability (HRV) derived from ECG recordings in two of the three participants (up to 0.86). Cross-correlation analysis revealed that the time lag between the onset of the exercise-induced increase in body temperature and the onset of sweating ranges from 600 to 740 s, in line with values predicted by the literature. These results demonstrate accurate, sensitive, and continuous tracking of sweat dynamics in real time. The proposed wearable OECT platform establishes a robust foundation for biomedical applications including monitoring of hydration disorders, electrolyte imbalance, metabolic dysfunction, and autonomic dysregulation.

  • Open Access

    Flexible Insole with Soft, Integrated, Polymeric Pressure Sensors to Discriminate Different Types of Gaits Using Machine Learning Techniques

    by Valentina Vit, Luca Liparulo, Ayub Alam, Riccardo Pecori, Nicola Coppedè

    Wearable sensors offer promising solutions for continuous gait monitoring in healthcare, rehabilitation, and sports. In this paper, a novel, soft, flexible, and easily made wearable sensor to detect the pressure generated by human gait was developed. The sensor consists of a soft polyurethane foam functionalized with a PEDOT:PSS aqueous solution designed to integrate the active material and develop a piezoresistive device. Eight soft sensors have been integrated into an insole, with dedicated readout electronic circuitry, including an accelerometer, a gyroscope, and a Bluetooth communication tag. Seven participants’ gaits were analyzed, and for each one, three types of walks were recorded: normal, prone, and supine. The data were analyzed with Machine Learning (ML) techniques, combining plantar pressure, accelerometer, and gyroscope features, to validate the device in discriminating among the three types of gaits. Ten supervised classifiers were assessed, such as Random Forest (RF), Support Vector Machine (SVM), Multi-layer Perceptron (MLP), K-Nearest Neighbors, and Gradient Boosting, using a sliding-window feature extraction pipeline and a chronological, per-recording train-test split designed to avoid information leakage between overlapping windows. Hyperparameter optimization was carried out via Randomized Search with a stratified 5-fold cross-validation protocol. The device has turned out to be suitable for detecting the three types of gaits thanks to the good results obtained by leveraging ML algorithms, reaching a classification accuracy of 90.38% on held-out data in a user-specific (subject-dependent) setting. In a stricter Leave-One-Subject-Out evaluation on participants never seen during training, accuracy reached 67.66%, about twice the chance level, without any labeled data from the new user. These results demonstrate the proposed flexible pressure system’s capability for continuous gait monitoring and support its use in healthcare diagnostics, rehabilitation evaluation, and sports biomechanics.

  • Open Access

    Cellulose-Based Nanosponges with PEDOT:PSS as Pressure Sensors with Tunable Elasticity: A Study on Modulation of Mechanical Properties and Pressure Response

    by V. Vit, L. Riva, V. Sinisi, A. Fiorati, A. Alam, A. B. Alabi, C. Punta, N. Coppedè

    This study investigates the suitability of sustainable, highly porous nanosponges, composed of TEMPO-oxidized cellulose nanofibers (TOCNF) and branched polyethylenimine (bPEI, cross-linker), as scaffolds for PEDOT:PSS poly(3,4-ethylenedioxythiophene):polystyrenesulfonate dip coating to design piezoresistive pressure sensors. The mechanical properties of the nanosponges were tuned by introducing citric acid (CA) as a co-cross-linker, varying its content from 0% to 18% relative to the moles of primary amines of bPEI. The resulting devices functioned effectively as pressure sensors, with the best performance achieved at 3% CA. This configuration operated reliably up to 200 kPa and reached a sensitivity of 1.96 × 10–3 mA·kPa–1. These findings confirm the promising performance of cellulose-based nanosponges and pave the way for their integration into lightweight and environmentally friendly pressure sensors.

  • Tumor microenvironment responsive CuV/DTPA@Catalase/5-fluorouracil nanodrug for reactive oxygen species modulation and breast cancer imaging

    by Iqra Iqbal, Ummama Saeed, Batool Fatima, Muhammad Imran, Dilshad Hussain, Ayub Alam, Rubaida Mahmood, Muhammad Najam-Ul-Haq

  • Open Access

    Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions

    by Ayub Alam, Faiqa Gull, Muzammal Hameed, Iqra Iqbal, Saira Naz, Hadia Noor, Ammara Aslam, Sana Younis, Valentina Vit, Muhammad Aqib Mehmood, et al.

    Non‐invasive biosensing has expanded blood‐based diagnostics into a growing set of accessible peripheral biofluids, yet most existing reviews remain confined to sweat, tears, saliva and urine, and treat the underlying literature descriptively rather than critically. Here, we present a review that extends this scope to include interstitial fluid and breath/exhaled breath condensate, two increasingly important non‐invasive matrices that have been largely absent from prior synthesis, and that explicitly distinguishes sensing strategies for small‐molecule metabolites from those for proteins and hormones, clarifying why the field has historically favoured the former and what emerging affinity‐based approaches (aptamers, molecularly imprinted polymers) are doing to close that gap. Beyond the electrochemical and optical platforms typically covered elsewhere, we introduce electrical, non‐faradaic transduction, including field‐effect transistor‐ and impedance‐based sensors, as a third major modality underpinning much of the current wearable sensor landscape. Rather than cataloguing individual devices, we critically compare reported sensitivity, selectivity and validation standards across studies within each biofluid class, highlighting where evidence is inconsistent or incomplete. Finally, we extend the discussion beyond device‐level advances to the translation barriers that determine real‐world deployment: the gap between laboratory demonstration and commercial product, regulatory pathways across major markets, patch‐to‐patch and device‐to‐device reproducibility and unresolved sensitivity/selectivity hurdles under real interferent conditions. Together, these additions position this review as a broader and more critically grounded synthesis of the painless biosensing landscape than currently available in the literature.


  • Open Access

    Electrochemical monitoring of PFOA in water using a Cu@rGO/Nb2O5 Nanohybrid sensor platform

    by Ayub Alam, Faiqa Gull, Saqib Shabbir, Sana Younis, Kiran Batool, Iqra Iqbal, Fatima Javed, Noreen Fatima


  • Retracted
    Open Access

    RETRACTED: Correlation of exchange coupling and dipolar interactions with magnetization reversal in strontium ferrite/nickel-doped cobalt ferrite composites

    by Saqib Shabbir, Ayub Alam, Muhammad Tayyab Iqbal, Aneeb Ullah, Gul Wali Khan, Muhammad Aqib, Sania Shabbir

  • Open Access

    Recent developments in electrochemical sensors for anticancer drugs analysis: Nanostructured innovations

    by Ayub Alam, Saqib Shabbir, Sania Shabbir, Samar Husnain, Iqra Iqbal, Aqsa Baig, Sana Younis, Faiqa Gull, Muhammad Aqib Mehmood, Muhammad Tayyab Iqbal, et al.


  • Open Access

    Highly sensitive electrochemical detection and quantification of opium derived morphine sulfate using cysteamine loaded MWCNTs@V2O5 telluride composite

    by Sana Shaheen, Batool Fatima, Dilshad Hussain, Ayub Alam, Muhammad Ayub, Muhammad Najam-Ul-Haq

    A novel electrochemical sensor based on multi-walled carbon nanotubes doped with vanadium pentoxide/telluride (MWCNTs@V2O5/Te) was developed for the detection and quantification of morphine sulfate in real biological samples. MWCNTs@V2O5/Te nanocomposite was functionalized with cysteamine as a linker, to create thiol interaction with the -OH group of the MWCNTs@V2O5/Te nanocomposite at one end, and free -NH2 group interaction with the -OH group on morphine sulfate, on the other end. This modification enhances the conjugation capability of morphine sulfate with the fabricated biosensor. (MWCNTs@V2O5/Te-Cys/GCE). MWCNTs@V2O5/Te nanocomposite morphological and structural analysis is carried out by SEM, TEM, EDX, FTIR, and UV-Vis spectroscopy. At varying concentrations and pH levels, the electrochemical sensor response of the modified electrode is investigated using cyclic voltammetry (CV). To validate the findings, differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and chronoamperometry are employed to investigate morphine sulfate detection, yielding excellent results in real biological samples. The fabricated sensor, as indicated by the calibration curve, exhibits a wide linear range of 10–60 µM and a limit of detection (LOD) of 0.01 µM by DPV. These results reveal that this novel sensor is highly stable, sensitive, and reproducible for detecting morphine sulfate. Therefore, this developed sensing platform can be used in clinical diagnostics, narcotics detection, and forensic analysis.