Shuo Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuo Ding has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Tao Zheng
North China Electric Power University
1 shared publication - Wenxuan Lv
State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 2267-2277
A Three-Phase Adaptive Reclosing Scheme of the Line Based on Active Injection of the Characteristic Voltage by HPFC
The hybrid power flow controller based on cascade H-bridge (HPFC) technology represents a versatile and cost-effective solution for power flow control. This device capitalizes on the strengths of phase-shifting transformers and power electronic devices, offering benefits for power grid optimization, renewable energy transmission, and flexible interconnection of regions. However, in the event of a permanent fault on the line with HPFC, conventional three-phase reclosing can lead to increased secondary short-circuit currents, posing significant risks to the power grid. The operational characteristics of HPFC render passive fault location methods less effective, thereby affecting fault localization accuracy. This paper presents a three-phase adaptive reclosing scheme for the line based on active injection of characteristic voltage by HPFC. By leveraging the unique features of HPFC, the scheme proposes a novel method for generating and injecting characteristic voltage. Considering factors such as current transformer measurements and transition resistance, the scheme introduces a fault nature criterion using staged characteristic voltage injection. This approach enhances the success rate of three-phase reclosing and ensures fault recovery capability. The feasibility of the proposed scheme is validated through a PSCAD/EMTDC simulation model of the line with HPFC.
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 2267-2277
A Three-Phase Adaptive Reclosing Scheme of the Line Based on Active Injection of the Characteristic Voltage by HPFC
The hybrid power flow controller based on cascade H-bridge (HPFC) technology represents a versatile and cost-effective solution for power flow control. This device capitalizes on the strengths of phase-shifting transformers and power electronic devices, offering benefits for power grid optimization, renewable energy transmission, and flexible interconnection of regions. However, in the event of a permanent fault on the line with HPFC, conventional three-phase reclosing can lead to increased secondary short-circuit currents, posing significant risks to the power grid. The operational characteristics of HPFC render passive fault location methods less effective, thereby affecting fault localization accuracy. This paper presents a three-phase adaptive reclosing scheme for the line based on active injection of characteristic voltage by HPFC. By leveraging the unique features of HPFC, the scheme proposes a novel method for generating and injecting characteristic voltage. Considering factors such as current transformer measurements and transition resistance, the scheme introduces a fault nature criterion using staged characteristic voltage injection. This approach enhances the success rate of three-phase reclosing and ensures fault recovery capability. The feasibility of the proposed scheme is validated through a PSCAD/EMTDC simulation model of the line with HPFC.