Xinran Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Harmonic modulation for ultrawide tuning range terahertz free-electron laser via frequency-beating laser modulation

    by Lingjun Tu, Yifan Liang, Hao Sun, Li Zeng, Huaiqian Yi, Xinran Wang, Yong Yu, Jitao Sun, Zhenbiao Sun, Guorong Wu, et al.

    Broadband tunability is a key pursuit for terahertz (THz) free-electron lasers, yet it is often constrained by the narrow energy acceptance of laser modulators in prebunched schemes. Here, we propose a harmonic modulation scheme to decouple this constraint. Taking the Electron Source Test Facility at Dalian as a specific case study, our simulations demonstrate that by matching the laser field to higher-order harmonic resonances of the undulator, we can obtain efficient energy modulation across a significantly wider electron energy range (40–130 MeV), surpassing the limit of 71–130 MeV imposed by the fundamental resonance. This technique facilitates continuous frequency tuning from 0.5 to 30 THz using a single modulator-radiator chain, establishing a versatile method for ultrabroadband THz generation.

  • Open Access

    Beam Dynamics Design of a Multi-Ion RFQ for Medical Application

    by Xinran Wang, Guiling Cao, Wenzhi Zhang

    Particle radiotherapy based on the medical accelerator is emerging as a major treatment for cancer. To enhance the clinical flexibility of particle radiotherapy and further promote the use of medical accelerators, the Shanghai Institute of Applied Physics (SINAP) has presented a new linear accelerator plan for medical application. The new plan utilizes a 200 MHz Radio Frequency Quadrupole (RFQ) as the injector. The RFQ is designed to accelerate ions with charge-to-mass ratios of 1/3 to 1/2 from 8 keV/u to 750 keV/u. For the beam dynamics design, a new design strategy is presented to enhance the suppression of space charge effects and improve beam capture efficiency by optimizing the modulation, synchronous phase, and focusing strength. The simulation results demonstrate that the multi-ion RFQ can operate at a maximum beam current of 3.2 mA while maintaining a transmission efficiency above 95% with a compact length of 2.5 m. Multi-particle simulations confirm the high reliability of the design. Additionally, input and mechanical error analyses evaluate the RFQ’s tolerance and stability. The research results demonstrate the feasibility of a compact, high-efficiency RFQ for multi-ion acceleration in medical applications, contributing to the advancement of particle therapy.