Ayten Odabas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ayten Odabas has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abdurrahman Dogan
Department of Pulmonary Medicine, Faculty of Medicine, Bursa Uludag University, 16059 Bursa, Turkey
1 shared publication - Asli Gorek Dilektasli
Department of Pulmonary Medicine, Bursa Uludag University, Bursa, Turkey
1 shared publication - Funda Coskun
Department of Chest Diseases, Uludağ University Faculty of Medicine, Bursa, Turkey
1 shared publication - Güven Özkaya
Department of Biostatistics, Faculty of Medicine, Bursa Uludağ University, Bursa 16059, Türkiye
1 shared publication - Ismet Polat
Department of Pulmonary Medicine, Faculty of Medicine, Bursa Uludag University, 16059 Bursa, Turkey
1 shared publication - Mehmet Karadag
Department of Pulmonology, Faculty of Medicine, Bursa Uludağ University, Bursa 16059, Türkiye
1 shared publication
Latest Publications
- Open Access
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1396
Home Spirometry for Post-COVID Recovery: A Clinical Validation Study of an Ultrasonic Device
Background/Objectives: Patients recovering from COVID-19 often experience persistent respiratory symptoms, necessitating pulmonary function monitoring. While clinical spirometry is the gold standard, home spirometry offers a remote alternative. This study evaluated the validity of an ultrasonic home-based spirometer for monitoring lung function in post-COVID-19 pneumonia patients over 12 weeks. Methods: This prospective study included 30 post-COVID pneumonia patients who underwent clinical spirometry at weeks 4, 8 and 12. Participants performed weekly home spirometry using the SpiroHome Personal® device. Agreement between home and clinical spirometry was assessed using a Bland–Altman analysis, intraclass correlation coefficients (ICCs), and Pearson correlation coefficients. Pulmonary function changes over time were analyzed using repeated measures ANOVA. Results: Home spirometry showed strong agreement with clinical spirometry for forced vital capacity (FVC) and forced expiratory volume in the first second (FEV1), with ICC values exceeding 0.92. The Bland–Altman analysis demonstrated minimal bias, though limits of agreement exceeded the clinically accepted threshold of ±150 mL. FEV1/FVC ratios showed greater variability. Pulmonary function improved significantly over 12 weeks for both methods (p < 0.002). Patient adherence to home spirometry remained high, with a median of 18.50 sessions [IQR: 15.00–26.00] and an overall compliance rate of 98.33% ± 9.13%. Conclusions: Home spirometry provides reliable pulmonary function measurements, particularly for FVC and FEV1, supporting its role as a remote monitoring tool. Despite minor variability in FEV1/FVC, home spirometry enables frequent assessment of lung function recovery, potentially reducing hospital visits and improving patient management.
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1396
Open AccessHome Spirometry for Post-COVID Recovery: A Clinical Validation Study of an Ultrasonic Device
Background/Objectives: Patients recovering from COVID-19 often experience persistent respiratory symptoms, necessitating pulmonary function monitoring. While clinical spirometry is the gold standard, home spirometry offers a remote alternative. This study evaluated the validity of an ultrasonic home-based spirometer for monitoring lung function in post-COVID-19 pneumonia patients over 12 weeks. Methods: This prospective study included 30 post-COVID pneumonia patients who underwent clinical spirometry at weeks 4, 8 and 12. Participants performed weekly home spirometry using the SpiroHome Personal® device. Agreement between home and clinical spirometry was assessed using a Bland–Altman analysis, intraclass correlation coefficients (ICCs), and Pearson correlation coefficients. Pulmonary function changes over time were analyzed using repeated measures ANOVA. Results: Home spirometry showed strong agreement with clinical spirometry for forced vital capacity (FVC) and forced expiratory volume in the first second (FEV1), with ICC values exceeding 0.92. The Bland–Altman analysis demonstrated minimal bias, though limits of agreement exceeded the clinically accepted threshold of ±150 mL. FEV1/FVC ratios showed greater variability. Pulmonary function improved significantly over 12 weeks for both methods (p < 0.002). Patient adherence to home spirometry remained high, with a median of 18.50 sessions [IQR: 15.00–26.00] and an overall compliance rate of 98.33% ± 9.13%. Conclusions: Home spirometry provides reliable pulmonary function measurements, particularly for FVC and FEV1, supporting its role as a remote monitoring tool. Despite minor variability in FEV1/FVC, home spirometry enables frequent assessment of lung function recovery, potentially reducing hospital visits and improving patient management.