Alexey Lubashevskiy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexey Lubashevskiy has a total of 526 co-authors. Here are the top co-authors by number of shared publications:
- Evgeny Yakushev
Joint Institute for Nuclear Research, Dubna 141980, Russia
6 shared publications - D. Zinatulina
Laboratory of Nuclear Problems, JINR
4 shared publications - Konstantin Shakhov
Joint Institute for Nuclear Research, Dubna 141980, Russia
4 shared publications - Maryvonne De Jesus
Université Lyon 1, CNRS, IP2I
4 shared publications - Sergey Rozovs
Joint Institute for Nuclear Research, Dubna 141980, Russia
4 shared publications - Vladimir Kazalov
Neutrino Observatory of INR RAS Baksan URL
4 shared publications
Latest Publications
- 31 October 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 239
First investigation of 96Zr samples enriched by the gas-centrifuge method for the use in rare-decay studies
- 31 October 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 239
First investigation of 96Zr samples enriched by the gas-centrifuge method for the use in rare-decay studies
- 8 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Evaluating the content of impurities in 3D-printing polymers with the instrumental neutron activation analysis for the use in low-background research
- 8 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Evaluating the content of impurities in 3D-printing polymers with the instrumental neutron activation analysis for the use in low-background research
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (10) , 105010
Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection
We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (10) , 105010
Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection
We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.
- Open Access
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
First investigation of 96Zr samples enriched by the gas-centrifuge method for the use in rare-decay studies
For the first time, the isotope 96Zr has been produced by the gas-centrifuge method (enrichment is 88.28% and full mass of 96Zr is 179.816 g). The level of radionuclide impurities of the samples and thus their suitability for rare-event search have been investigated using three low-background HPGe detectors. The most stringent limit, obtained at sea level, on the half-life of the double beta decay of 96Zr to the 0+1 excited state (1148 keV) of 96Mo has been set T1/2(0ν+2ν)>3.9×1019 yr (90% C.L.).
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFirst investigation of 96Zr samples enriched by the gas-centrifuge method for the use in rare-decay studies
For the first time, the isotope 96Zr has been produced by the gas-centrifuge method (enrichment is 88.28% and full mass of 96Zr is 179.816 g). The level of radionuclide impurities of the samples and thus their suitability for rare-event search have been investigated using three low-background HPGe detectors. The most stringent limit, obtained at sea level, on the half-life of the double beta decay of 96Zr to the 0+1 excited state (1148 keV) of 96Mo has been set T1/2(0ν+2ν)>3.9×1019 yr (90% C.L.).
- Top Cited PapersOpen Access
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
Top Cited PapersOpen AccessFirst Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- Open Access
- 22 December 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (11)
Characterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin
The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14 ( 3 ) events / ( kg day keV ) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of < 9 events / ( kg day keV ) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events / ( kg day keV ) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.
- 22 December 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (11)
Open AccessCharacterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin
The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14 ( 3 ) events / ( kg day keV ) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of < 9 events / ( kg day keV ) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events / ( kg day keV ) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.
- Open Access
- 1 April 2016
- Published by Elsevier in Nuclear and Particle Physics Proceedings
- Vol. 273-275, 1876-1882
Search of Neutrinoless Double Beta Decay with the GERDA Experiment
- 1 April 2016
- Published by Elsevier in Nuclear and Particle Physics Proceedings
- Vol. 273-275, 1876-1882
Open AccessSearch of Neutrinoless Double Beta Decay with the GERDA Experiment