María Pérez-Rodríguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
María Pérez-Rodríguez has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Gabriel Bernardino
Universitat Pompeu Fabra
2 shared publications - A. Fernández
BCNatal Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu) Barcelona Spain
1 shared publication - Alvaro Sepúlveda-Martínez
Fetal Medicine Unit, Department of Obstetrics and Gynecology, Hospital Clínico Universidad de Chile, Santiago de Chile, Chile
1 shared publication Anna Pellisé-Tintoré
Affiliation Department of Engineering, Universitat Pompeu Fabra, Barcelona, Spain
1 shared publicationBart Bijnens
Affiliations Department of Engineering, Universitat Pompeu Fabra, Barcelona, Spain, ICREA - Catalan Institution for Research and Advanced Studies, Barcelona, Spain
1 shared publication- Bart Bijnens
ICREA
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 68 (4) , 540-549
Fetal aortic morphometry by echocardiography: reproducibility study using stringent criteria and standardized nomenclature
Objective: To establish and assess the reproducibility of standardized echocardiographic nomenclature and the protocol for comprehensive evaluation of fetal aortic morphology. Methods: This was a prospective cohort study of fetuses with a normal three‐vessel branching pattern of the aortic arch, evaluated from 18–40 weeks' gestation at a single center between January 2024 and November 2024. Alongside standard two‐dimensional views, four‐dimensional spatiotemporal image correlation cardiac volumes were acquired to establish the correspondence between the longitudinal aortic‐arch view and the three‐vessel‐and‐trachea (3VT) view. A comprehensive nomenclature, based on clear anatomical landmarks, and stringent measurement protocol were defined for fetal aortic dimensions and angles measured in the left ventricular outflow tract (LVOT), the longitudinal aortic‐arch and the 3VT echocardiographic views. Measurements were performed independently by two observers, with a repeat analysis by a single observer, to assess intra‐ and interobserver reproducibility, respectively, using intraclass correlation coefficients (ICCs). Results: A total of 45 singleton fetuses with normal three‐vessel branching were randomly selected to comprise the study population. Parameters measured in the LVOT view demonstrated good‐to‐excellent intra‐ and interobserver reproducibility (ICC > 0.8), with excellent reproducibility observed for the sinotubular junction and mid‐ascending aorta diameters (except the interobserver reproducibility for mid‐ascending aorta diameter (ICC, 0.883 (95% CI, 0.739–0.945)), which was good). Good‐to‐excellent intra‐ and interobserver reproducibility (ICC, 0.8–0.9) was also demonstrated for longitudinal aortic‐arch diameters and distances between supra‐aortic vessels, whereas the ascending‐to‐descending aorta angle showed moderate intra‐ and interobserver reproducibility (ICC, 0.652 (95% CI, 0.435–0.798) and 0.593 (95% CI, 0.199–0.776), respectively). In the 3VT view, the standardized aortic diameters and the 3VT angle had good‐to‐excellent intraobserver reproducibility (ICC, 0.75–0.9). There was also good agreement between the aortic isthmus diameter in the longitudinal aortic‐arch view and the 3VT view (ICC, 0.870 (95% CI, 0.458–0.995); P < 0.001). No significant differences or systematic bias were found between observers. Conclusion: A standardized echocardiographic protocol with uniform nomenclature and anatomical landmarks would enable reliable and reproducible fetal aortic morphometry across multiple echocardiographic views, and would be a significant step towards harmonizing fetal aorta imaging, enabling meaningful comparisons across studies and promoting collaborative research. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
- 11 September 2026
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 68 (4) , 540-549
Open AccessFetal aortic morphometry by echocardiography: reproducibility study using stringent criteria and standardized nomenclature
Objective: To establish and assess the reproducibility of standardized echocardiographic nomenclature and the protocol for comprehensive evaluation of fetal aortic morphology. Methods: This was a prospective cohort study of fetuses with a normal three‐vessel branching pattern of the aortic arch, evaluated from 18–40 weeks' gestation at a single center between January 2024 and November 2024. Alongside standard two‐dimensional views, four‐dimensional spatiotemporal image correlation cardiac volumes were acquired to establish the correspondence between the longitudinal aortic‐arch view and the three‐vessel‐and‐trachea (3VT) view. A comprehensive nomenclature, based on clear anatomical landmarks, and stringent measurement protocol were defined for fetal aortic dimensions and angles measured in the left ventricular outflow tract (LVOT), the longitudinal aortic‐arch and the 3VT echocardiographic views. Measurements were performed independently by two observers, with a repeat analysis by a single observer, to assess intra‐ and interobserver reproducibility, respectively, using intraclass correlation coefficients (ICCs). Results: A total of 45 singleton fetuses with normal three‐vessel branching were randomly selected to comprise the study population. Parameters measured in the LVOT view demonstrated good‐to‐excellent intra‐ and interobserver reproducibility (ICC > 0.8), with excellent reproducibility observed for the sinotubular junction and mid‐ascending aorta diameters (except the interobserver reproducibility for mid‐ascending aorta diameter (ICC, 0.883 (95% CI, 0.739–0.945)), which was good). Good‐to‐excellent intra‐ and interobserver reproducibility (ICC, 0.8–0.9) was also demonstrated for longitudinal aortic‐arch diameters and distances between supra‐aortic vessels, whereas the ascending‐to‐descending aorta angle showed moderate intra‐ and interobserver reproducibility (ICC, 0.652 (95% CI, 0.435–0.798) and 0.593 (95% CI, 0.199–0.776), respectively). In the 3VT view, the standardized aortic diameters and the 3VT angle had good‐to‐excellent intraobserver reproducibility (ICC, 0.75–0.9). There was also good agreement between the aortic isthmus diameter in the longitudinal aortic‐arch view and the 3VT view (ICC, 0.870 (95% CI, 0.458–0.995); P < 0.001). No significant differences or systematic bias were found between observers. Conclusion: A standardized echocardiographic protocol with uniform nomenclature and anatomical landmarks would enable reliable and reproducible fetal aortic morphometry across multiple echocardiographic views, and would be a significant step towards harmonizing fetal aorta imaging, enabling meaningful comparisons across studies and promoting collaborative research. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (5) , e1013096
Understanding the hemodynamic changes in fetuses with coarctation of the aorta using a lumped model of fetal circulation
Coarctation of the aorta (CoA) is a common congenital heart defect characterized by aortic narrowing. Prenatally, it has mild hemodynamic effects as right ventricular disproportion and ductus arteriosus (DA) dilation occur as adaptive mechanisms, but their impact on CoA hemodynamics remains poorly understood. To investigate this, we built a closed 0D computational model of fetal circulation and simulated different CoA cardiovascular remodeling patterns, including aortic isthmus (AoI) narrowing, ventricular disproportion, and DA dilation. Our results showed mild AoI narrowing (80% of reference diameter) required up to 1.7 right/left ventricular end-diastolic volume ratio and 115% DA dilation to maintain physiological pressures, wall shear stresses, and organ perfusion. In contrast, severe narrowing (20% of reference AoI diameter) required up to 5 right/left ventricular end-diastolic volume ratio and 125% DA dilation, highlighting the necessity of co-occurrence of prenatal ventricular disproportion and DA dilation to compensate for AoI narrowing. These physiological regions were validated with ultrasonographic measurements from 7 controls and 9 CoA patients. We compared blood pressures, velocities, and volumetric flow rates across different fetoplacental anatomical sites. AoI velocity showed a delayed retrograde flow peak and increased antegrade diastolic velocity with greater AoI narrowing, which may aid in diagnosing CoA. Minimal differences were observed in other velocities and pressures. Volumetric flow rates across varying degrees of AoI narrowing decreased in the AoI and mitral and aortic valves, remained stable in the middle cerebral and umbilical arteries, and increased in the DA and tricuspid and pulmonary valves. Therefore, we corroborated that in fetal CoA a redistribution of blood flow occurs to ensure perfusion of the brain and placenta, without a significant alteration in fetal hemodynamics (blood pressure and velocities) except for increased diastolic velocities in the AoI.
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (5) , e1013096
Open AccessUnderstanding the hemodynamic changes in fetuses with coarctation of the aorta using a lumped model of fetal circulation
Coarctation of the aorta (CoA) is a common congenital heart defect characterized by aortic narrowing. Prenatally, it has mild hemodynamic effects as right ventricular disproportion and ductus arteriosus (DA) dilation occur as adaptive mechanisms, but their impact on CoA hemodynamics remains poorly understood. To investigate this, we built a closed 0D computational model of fetal circulation and simulated different CoA cardiovascular remodeling patterns, including aortic isthmus (AoI) narrowing, ventricular disproportion, and DA dilation. Our results showed mild AoI narrowing (80% of reference diameter) required up to 1.7 right/left ventricular end-diastolic volume ratio and 115% DA dilation to maintain physiological pressures, wall shear stresses, and organ perfusion. In contrast, severe narrowing (20% of reference AoI diameter) required up to 5 right/left ventricular end-diastolic volume ratio and 125% DA dilation, highlighting the necessity of co-occurrence of prenatal ventricular disproportion and DA dilation to compensate for AoI narrowing. These physiological regions were validated with ultrasonographic measurements from 7 controls and 9 CoA patients. We compared blood pressures, velocities, and volumetric flow rates across different fetoplacental anatomical sites. AoI velocity showed a delayed retrograde flow peak and increased antegrade diastolic velocity with greater AoI narrowing, which may aid in diagnosing CoA. Minimal differences were observed in other velocities and pressures. Volumetric flow rates across varying degrees of AoI narrowing decreased in the AoI and mitral and aortic valves, remained stable in the middle cerebral and umbilical arteries, and increased in the DA and tricuspid and pulmonary valves. Therefore, we corroborated that in fetal CoA a redistribution of blood flow occurs to ensure perfusion of the brain and placenta, without a significant alteration in fetal hemodynamics (blood pressure and velocities) except for increased diastolic velocities in the AoI.