Shu-Hong Chang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shu-Hong Chang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Adam J. King
Department of Biostatistics, University of California Los Angeles School of Public Health, Los Angeles, California, U.S.A.
1 shared publicationKonstantinos I. Papageorgiou
Division of Orbital and Ophthalmic Plastic and Reconstructive Surgery, Jules Stein Eye Institute and
1 shared publicationKris S. Moe
Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology-Head and Neck Surgery, University of Washington Seattle, WashingtonUSA
1 shared publicationMichael Ang
David Geffen School of Medicine, University of California Los Angeles; and
1 shared publicationMichael C. Chappell
Division of Orbital and Ophthalmic Plastic Surgery, University of Washington Eye Institute , Seattle, Washington , USA , and
1 shared publicationRobert A. Goldberg
Division of Orbital and Ophthalmic Plastic and Reconstructive Surgery, Jules Stein Eye Institute and
1 shared publication
Latest Publications
- 10 January 2014
- Published by Taylor & Francis in Orbit
- Vol. 33 (4) , 270-275
Learning Curve for use of the Sonopet Ultrasonic Aspirator in Endoscopic Dacryocystorhinostomy
Purpose: The Sonopet Ultrasonic Aspirator is a surgical tool that uses low-frequency ultrasonic vibrations to fragment tissue while simultaneously irrigating and aspirating the surgical field. This technology is becoming more widely used in orbital, lacrimal, neurological, and skull base surgery, but few studies have examined the learning curve associated with adoption of this technology. We present our surgical learning curve, pearls, and pitfalls using the newest generation Sonopet Ultrasonic Aspirator Universal handpiece in endoscopic dacryocystorhinostomy (eDCR) surgery. Methods: Retrospective chart review of consecutive eDCR surgeries performed by a single surgeon adopting the Sonopet Universal handpiece. Data collected include demographic information, indications for surgery, surgical time, intraoperative findings, anatomic and functional results, and complications. Results: Twenty-six eDCR surgeries in 20 patients were performed from October 2011 – May 2013. Most patients were female (85.7%) with mean age 53.6 years (range 4–84) and mean follow up of 378 days (range 7–761). For routine unilateral and bilateral surgeries, surgery time decreased by 36.4% and 33.9% before reaching a plateau of 67.2 and 80.7 minutes per case, respectively. Mean surgery time for non-sequential unilateral complex cases was 85.1 minutes, which did not vary significantly over the learning curve. We achieved 100% anatomic success and 84.6% functional success. Conclusions: The Sonopet Ultrasonic Aspirator Universal handpiece can be used safely and effectively for eDCR surgery. A significant learning curve exists for adoption of this technology. Appropriate handpiece tip selection and machine setting adjustments are crucial for successful adoption of this technology and avoidance of complications.
- 10 January 2014
- Published by Taylor & Francis in Orbit
- Vol. 33 (4) , 270-275
Learning Curve for use of the Sonopet Ultrasonic Aspirator in Endoscopic Dacryocystorhinostomy
Purpose: The Sonopet Ultrasonic Aspirator is a surgical tool that uses low-frequency ultrasonic vibrations to fragment tissue while simultaneously irrigating and aspirating the surgical field. This technology is becoming more widely used in orbital, lacrimal, neurological, and skull base surgery, but few studies have examined the learning curve associated with adoption of this technology. We present our surgical learning curve, pearls, and pitfalls using the newest generation Sonopet Ultrasonic Aspirator Universal handpiece in endoscopic dacryocystorhinostomy (eDCR) surgery. Methods: Retrospective chart review of consecutive eDCR surgeries performed by a single surgeon adopting the Sonopet Universal handpiece. Data collected include demographic information, indications for surgery, surgical time, intraoperative findings, anatomic and functional results, and complications. Results: Twenty-six eDCR surgeries in 20 patients were performed from October 2011 – May 2013. Most patients were female (85.7%) with mean age 53.6 years (range 4–84) and mean follow up of 378 days (range 7–761). For routine unilateral and bilateral surgeries, surgery time decreased by 36.4% and 33.9% before reaching a plateau of 67.2 and 80.7 minutes per case, respectively. Mean surgery time for non-sequential unilateral complex cases was 85.1 minutes, which did not vary significantly over the learning curve. We achieved 100% anatomic success and 84.6% functional success. Conclusions: The Sonopet Ultrasonic Aspirator Universal handpiece can be used safely and effectively for eDCR surgery. A significant learning curve exists for adoption of this technology. Appropriate handpiece tip selection and machine setting adjustments are crucial for successful adoption of this technology and avoidance of complications.
- 1 September 2013
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 29 (5) , 382-385
High-Resolution Ultrasound as an Effective and Practical Tool to Analyze Eyebrow Profile Expansion in Thyroid-Associated Periorbitopathy
Purpose: Clinical, radiographic, and molecular studies have shown that patients with thyroid-associated orbitopathy exhibit volumetric expansion of eyebrow tissues. This clinicopathologic entity has been termed thyroid-associated periorbitopathy. The goal of this study was to determine whether high-resolution ultrasonography could be used to reliably quantify thyroid-associated periorbitopathy. Methods: Institutional review board approval was obtained. The internal case-control study consisted of 12 subjects with unilateral-asymmetric thyroid-associated orbitopathy. High-resolution ultrasonography using a 15-MHz probe (Logiq p6) was performed by a single operator. Measurements were obtained 0.5 cm cephalad to the superior orbital rim at the midpupillary sagittal level. For each subject and tissue layer thickness (total tissue, dermis fat, retro-orbicularis oculi fat), the measured values on the less affected side were subtracted from those on the more severely diseased side. Summary statistics were used to analyze results. Results: High-resolution ultrasonography effectively demonstrated asymmetric expansion of total eyebrow tissue (p < 0.0001) and retro-orbicularis oculi fat (p = 0.0003). No significant difference in dermis fat thickness was found between the 2 sides (p = 0.2). Hertel exophthalmometry measurements were statistically different between the 2 sides (p = 0.002). Conclusions: This study demonstrates that high-resolution ultrasonography independently confirms previously published studies of retro-orbicularis oculi fat expansion in patients with thyroid-associated orbitopathy. Compared with CT, MRI, and tissue biopsy, high-resolution ultrasonography is a more practical and cost-effective way to quantify and track thyroid-associated periorbitopathy over time. With its potential for real-time tissue assessment, high-resolution ultrasonography may be best suited for future studies of the dynamic relationship between globe and periorbital structures.
- 1 September 2013
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 29 (5) , 382-385
High-Resolution Ultrasound as an Effective and Practical Tool to Analyze Eyebrow Profile Expansion in Thyroid-Associated Periorbitopathy
Purpose: Clinical, radiographic, and molecular studies have shown that patients with thyroid-associated orbitopathy exhibit volumetric expansion of eyebrow tissues. This clinicopathologic entity has been termed thyroid-associated periorbitopathy. The goal of this study was to determine whether high-resolution ultrasonography could be used to reliably quantify thyroid-associated periorbitopathy. Methods: Institutional review board approval was obtained. The internal case-control study consisted of 12 subjects with unilateral-asymmetric thyroid-associated orbitopathy. High-resolution ultrasonography using a 15-MHz probe (Logiq p6) was performed by a single operator. Measurements were obtained 0.5 cm cephalad to the superior orbital rim at the midpupillary sagittal level. For each subject and tissue layer thickness (total tissue, dermis fat, retro-orbicularis oculi fat), the measured values on the less affected side were subtracted from those on the more severely diseased side. Summary statistics were used to analyze results. Results: High-resolution ultrasonography effectively demonstrated asymmetric expansion of total eyebrow tissue (p < 0.0001) and retro-orbicularis oculi fat (p = 0.0003). No significant difference in dermis fat thickness was found between the 2 sides (p = 0.2). Hertel exophthalmometry measurements were statistically different between the 2 sides (p = 0.002). Conclusions: This study demonstrates that high-resolution ultrasonography independently confirms previously published studies of retro-orbicularis oculi fat expansion in patients with thyroid-associated orbitopathy. Compared with CT, MRI, and tissue biopsy, high-resolution ultrasonography is a more practical and cost-effective way to quantify and track thyroid-associated periorbitopathy over time. With its potential for real-time tissue assessment, high-resolution ultrasonography may be best suited for future studies of the dynamic relationship between globe and periorbital structures.